Mark A. Law MD's research while affiliated with University of Alabama at Birmingham and other places

What is this page?


This page lists the scientific contributions of an author, who either does not have a ResearchGate profile, or has not yet added these contributions to their profile.

It was automatically created by ResearchGate to create a record of this author's body of work. We create such pages to advance our goal of creating and maintaining the most comprehensive scientific repository possible. In doing so, we process publicly available (personal) data relating to the author as a member of the scientific community.

If you're a ResearchGate member, you can follow this page to keep up with this author's work.

If you are this author, and you don't want us to display this page anymore, please let us know.

Publications (1)


Pulmonary Artery Stents: Long-Term Follow-Up
  • Article

April 2010

·

50 Reads

·

76 Citations

Catheterization and Cardiovascular Interventions

Mark A. Law MD

·

·

Alan W. Nugent MD

·

[...]

·

Objectives: Determine the long-term outcomes of branch pulmonary artery (PA) stents. Background: PA stents in congenital heart disease effectively relieve stenoses in the short-term. Published long-term data are limited. Methods: Patients enrolled in an FDA IDE protocol from 1989-92 were included. Clinical follow-up and catheterization data were evaluated. Patients were included if >5 year follow-up data was available or if mortality occurred following the initial procedure. Results: There were five deaths: four due to progression of their underlying heart disease, and one from a complication during a follow-up catheterization. Clinical data for 43 surviving patients demonstrated 39 patients (91%) are in NYHA class I or II. Seven patients underwent surgical intervention during the follow-up period (five RV-PA conduit, two Fontan revisions), but none addressed PA stenosis. Final repeat catheterizations were performed in 36 patients (55 stents) 7.2 +/- 4.3 years post stent insertion with 1.2 +/- 0.9 further procedures with stent dilations. In this subgroup, the minimum vessel diameter increased from 4.7 +/- 1.8 to 13.4 +/- 2.4 mm (P < 0.001), and the pressure gradient improved from 41 +/- 25 to 9 +/- 11 mm Hg (P < 0.001). Higher initial gradient and smaller balloons were associated with a final stent diameter of <14 mm (P = 0.030 and 0.046). Jailed vessels occurred in 49% of stents with abnormal angiographic flow in 18/55. Six repeat catheterizations resulted in complications, including the one procedural death. Conclusion: Stents implants for PA stenoses provide effective improvement in vessel caliber in the long-term. Although repeat interventions are necessary, this procedure reduces RV pressure and provides an important alternative to surgery for residual PA obstruction.

Share

Citations (1)


... This property presents several advantages, including reduced complications and the necessity for revision surgery, the avoidance of long-term anticoagulation issues, and the elimination of CT/MRI imaging artifacts. As a result, they hold great promise as an alternative to traditional metal implants [2][3][4]. ...

Reference:

Comparative Study of Porous Iron Foams for Biodegradable Implants: Structural Analysis and In Vitro Assessment
Pulmonary Artery Stents: Long-Term Follow-Up
  • Citing Article
  • April 2010

Catheterization and Cardiovascular Interventions