It was automatically created by ResearchGate to create a record of this author's body of work. We create such pages to advance our goal of creating and maintaining the most comprehensive scientific repository possible. In doing so, we process publicly available (personal) data relating to the author as a member of the scientific community.

If you're a ResearchGate member, you can follow this page to keep up with this author's work.

If you are this author, and you don't want us to display this page anymore, please let us know.

Publications (1)


Detecting Early to Mild Glaucomatous Damage: A Comparison of the Multifocal VEP and Automated Perimetry
  • Article

February 2004

·

11 Reads

·

82 Citations

Investigative Opthalmology & Visual Science

Donald C. Hood

purpose. To gain better understanding of the relationship between abnormalities detected by the multifocal VEP (mfVEP) compared with those detected by static achromatic, automated perimetry in patients with glaucoma. methods. Fifty patients were studied who had open-angle glaucoma that met the following criteria: (1) a mean deviation (MD) of better than −8 dB in both eyes on the 24-2 Humphrey visual field (HVF) test (Carl Zeiss Meditec, Dublin, CA); and (2) glaucomatous damage in at least one eye, as defined by a glaucomatous optic disc and an abnormal 24-2 HVF test result (pattern standard deviation [PSD] <5% and/or glaucoma hemifield test [GHT] results outside normal limits). Monocular mfVEPs were obtained from each eye by using a pattern-reversal dartboard array, 44.5° in diameter, which contained 60 sectors. Recording electrodes were placed at the inion (I) and I+4 cm, and also at two lateral locations up 1 cm and over 4 cm from I. Monocular and interocular mfVEP probability plots were derived by comparing the results with those of normal control subjects. For both the HVF and mfVEP probability plots, a hemifield was classified as abnormal if three or more contiguous points were significant at less than 5%, with at least one at less than 1%. results. Of the 200 hemifields tested (50 patients × two eyes × two hemifields), 75 showed significant clusters on the HVF, and 74 (monocular probability plot) and 93 (monocular or interocular plot) showed significant clusters on the mfVEP. Overall, the HVF and mfVEP results agreed on 74% of the hemifields, and 90 hemifields were normal and 58 were abnormal on both the mfVEP (interocular and/or monocular abnormal) and HVF cluster tests. Of the 52 disagreements, 35 hemifields had a significant cluster on the mfVEP, but not on the HVF, whereas the reverse was true of 17 hemifields. A case-by-case analysis indicated that misses and false-positive results occurred on both the HVF and mfVEP tests. conclusions. As predicted from a theoretical analysis, under these conditions (i.e., the signal-to-noise level) the HVF and monocular mfVEP tests showed a comparable number of defects, and, with the addition of the interocular test, the mfVEP showed more abnormalities than the HVF. However, although there were abnormalities detected by the mfVEP that were missed by the HVF, the reverse was true as well.

Share

Citations (1)


... Jest to szczególnie ważne u pacjentów słabo współpracujących lub mających trudności w wykonaniu perymetrii [67]. Wyniki badań wykazują dobrą korelację między czułością siatkówki w polu widzenia a wynikami mfVEP [68]. Ograniczeniami badania mfVEP jest to, że jest ono czasochłonne, wymaga dokładnego przygotowania oraz jest możliwe do przeprowadzenia tylko w pracowni elektrofizjologicznej. ...

Reference:

Innovations in glaucoma diagnostics
Detecting Early to Mild Glaucomatous Damage: A Comparison of the Multifocal VEP and Automated Perimetry
  • Citing Article
  • February 2004

Investigative Opthalmology & Visual Science