Abstract
M.T. Holmberg et al. comment on the original paper by P.P. Reichmeider (see ibid., vol.15, no.4, p.380-3, 2000). They briefly mention the rotor d-axis alignment and fault location computation for partitioned windings. The original authors reply to the comments
For pt.I see ibid., vol.15, no.4, p.376-9 (2000). This paper
applies techniques for analyzing internal phase and ground faults in the
stator windings of large synchronous machines. A variety of internal
fault conditions are considered, with results for a 75% ground fault
presented, along with comprehensive data for a test machine. The
methodology is validated by comparison with results obtained from
independent finite element analyses