Conference PaperPDF Available

EXPERIMENTAL EVALUATION OF THE HEAT TRANSFER COEFFICIENT DURING FLOW BOILING OF DI-WATER IN A STAINLESS STEEL TUBE COATED WITH SIO 2 NANOPARTICLES

Authors:

Abstract and Figures

The present paper reports experimental results for the heat transfer coefficient during flow boiling of DI-water in a stainless steel (AISI-304) tube with internal diameter of 1.1 mm. The internal surface of the channel was coated through a boiling process using nanofluids composed of DI-water and SiO 2. Nanofluids were prepared using two sizes of spherical SiO 2 nanoparticles, corresponding to diameters of 15 nm and 80 nm. Tubes were nanocoated using nanofluids with volumetric concentrations of 0.001, 0.01 and 0.1% for each nanoparticle size. Flow boiling results were also obtained for DI-water in a surface without coating. For nanoparticles with diameter of 15 nm, the experimental data reveal that the nanocoating causes a reduction of the heat transfer coefficient. It was also observed that the heat transfer coefficient reduction is intensified by increasing the volumetric concentration of nanoparticles used for the deposition process. On other hand, for nanoparticles of 80 nm, the heat transfer coefficient was almost unaffected by the SiO 2 nanocoating.
Content may be subject to copyright.
Proceedings of ENCIT 2016 16th Brazilian Congress of Thermal Sciences and Engineering
Copyright © 2012 by ABCM November 07-10th, 2016, Vitória, ES, Brazil
EXPERIMENTAL EVALUATION OF THE HEAT TRANSFER
COEFFICIENT DURING FLOW BOILING OF DI-WATER IN A
STAINLESS STEEL TUBE COATED WITH SIO2 NANOPARTICLES
Tiago Augusto Moreira, tiago.moreira@usp.br
Francisco Júlio do Nascimento, f.nascimento44@gmail.com
Gherhardt Ribatski, ribatski@sc.usp.br
Heat Transfer Research Group, Escola de Engenharia de São Carlos, University of Sao Paulo, Av. Trabalhador San-carlense, 400,
Parque Arnold Schimidt, Sao Carlos, CEP:13566-590, Brazil
Abstract. The present paper reports experimental results for the heat transfer coefficient during flow boiling of DI-
water in a stainless steel (AISI-304) tube with internal diameter of 1.1 mm. The internal surface of the channel was
coated through a boiling process using nanofluids composed of DI-water and SiO2. Nanofluids were prepared using
two sizes of spherical SiO2 nanoparticles, corresponding to diameters of 15 nm and 80 nm. Tubes were nanocoated
using nanofluids with volumetric concentrations of 0.001, 0.01 and 0.1% for each nanoparticle size. Flow boiling
results were also obtained for DI-water in a surface without coating. For nanoparticles with diameter of 15 nm, the
experimental data reveal that the nanocoating causes a reduction of the heat transfer coefficient. It was also observed
that the heat transfer coefficient reduction is intensified by increasing the volumetric concentration of nanoparticles
used for the deposition process. On other hand, for nanoparticles of 80 nm, the heat transfer coefficient was almost
unaffected by the SiO2 nanocoating.
Keywords: heat transfer coefficient, flow boiling, coated surface, nanoparticles, nanofluids, microchannels
1. NOMENCLATURE
ABN Surface coated with nanofluids
BBN Surface without deposition
G Mass velocity, kg/m2s
ID Internal diameter
h Heat transfer coefficient, W/m2°C
q Heat flux, W/m2
Twall Temperature of the internal tube wall, °C
Tbulk Fluid bulk temperature, °C
2. INTRODUCTION
Since Choi and Eastman (1995) introduced the term “nanofluid” to nominate the addition of nanoparticles to a base
fluid in order to improve its thermal conductivity and, consequently, the heat transfer coefficient in convective heat
transfer processes, several research paths were opened concerning this new research area. Studies were performed
focusing on characterizing the properties of these fluids, principally the viscosity and conductivity, obtaining the
stabilization of these suspensions and investigating the heat transfer coefficient and pressure drop provided by this
fluids for single-phase convection and flow and pool boiling.
It is consensus in the literature that for pool and flow boiling heat transfer the main consequence of adding
nanoparticles to a base fluid is the deposition of nanoparticles on the heated wall (Wen et al., 2011; Diao et al., 2013;
Valfei and Borca-Tasciuc, 2014; Souza et al., 2014; Fang et al., 2015), modifying the surface structure, the surface-
liquid interactions and the size of the cavities on the surface. These modifications can promote either augmentation or
reduction of the active site density implying on variations on the heat transfer coefficient. The relative effect of the
nanoparticle deposition on the heat transfer coefficient seems related to the combination of surface roughness and
nanoparticle size, as pointed out by Souza et al. (2014) and Wen et al. (2011).
In the present study, the effect of nanoparticle deposition on the surface into the heat transfer coefficient during
flow boiling of DI-water in a 1.1 ID stainless steel AISI-304 tube was investigated. The nanoparticle deposition was
obtained by performing previously to the tests with DI-water, flow boiling experiments with spherical SiO2
nanoparticles with diameters of 15 and 80 nm and volumetric concentrations of 0.001, 0.01 and 0.1%
3. EXPERIMENTAL APPARATUS AND PROCEDURE
3.1 Experimental facility
Figure 1 illustrates the experimental apparatus and details of the test section. In the facility, the test fluid is driven
from the reservoir through the circuit by a gear pump (Micropump GA-T23). The mass flow rate is estimated from
single-phase pressure drop measurements through a 2.0 mm ID, 100 mm long quartz tube using a differential pressure
transducer (Endress+Hauser PMD75) with a measurement span of 0-3 kPa. Calibration curves were previously adjusted
correlating the pressure drop and mass flow rate using as reference the mass deposition in a digital analytical balance
Proceedings of ENCIT 2016 16th Brazilian Congress of Thermal Sciences and Engineering
Copyright © 2012 by ABCM November, 07-10th, 2016, Vitória, ES, Brazil
(precision 0.01 g). During these testes, the test facility was run as an open circuit. Such procedure was implemented to
avoid possible effects on the flow rate measurements of nanoparticles deposition on the internal parts of commercial
and non-internally inpectable flow meters. The error associated with the mass flow meter was found equal to as 4.6% of
the measured value with reliability of 95.4%.
A pre-heater consisting of a tube-in-tube heat exchanger is used to impose the inlet temperature of the test fluid at
the test section. This heat exchanger uses as heating source a thermal fluid (capable of working at temperatures up to
317°C) whose temperature is controlled by a thermal bath. Needle valves located upstream and downstream of the test
section are used to minimize two-phase flow oscillations due to the confined bubble formation. At the test section
entrance, measurements of bulk temperature, using a thermocouple positioned within the flow, and absolute pressure,
using a pressure transducer (Endress+Hauser PMP131 for 0-400 kPa) were performed. The differential pressure along
the test section was measured with a differential pressure transducer (Endress+Hauser PMD75 for 0-300 kPa). The
outlet temperature was measured through a thermocouple positioned within the flow. The wall temperature was
measured with thermocouples fixed on the external wall of the test section at the top and bottom of each section. Wall
temperatures were measured at 5 cross-sections distributed along the heated length of the test tube.
Figure 1. Illustration of the test facility.
The test section is a stainless steel tube (AISI-304) with internal diameter of 1.1 mm and 200 mm long. The heating
effect of the test section was obtained by supplying electrical current from a DC power source (TDK-Lambda GEN
20V-76A) directly to the test surface. All temperatures were measured with K-type thermocouples with hot junction
diameters of 0.152 mm. Just downstream the test section is a 1.0 mm ID and 100 mm long quarts tube, installed in order
to allow two-phase flow visualizations with a high-speed camera. Downstream the transparent tube is a heat exchanger
(condenser) responsible for condensing and subcool the test fluid by rejecting heat to a secondary fluid which
temperature is controlled by a second thermal bath. The condenser, the pre-heater, the flow meter and the reservoir are
made of borosilicate glass, allowing the evaluation of deposition of nanoparticles along the circuit. To record the data
and to monitor and control the experimental apparatus, a LabView program was used with a National Instruments data
acquisition system (SCXI-1000 with SCXI-1102 thermocouples module).
The test facility and the data regression procedure were validated through comparisons of heat transfer and pressure
drop experimental results for single-phase flow and well-established predictive methods from literature (see Moreira et
al., 2015).
Proceedings of ENCIT 2016 16th Brazilian Congress of Thermal Sciences and Engineering
Copyright © 2012 by ABCM November 07-10th, 2016, Vitória, ES, Brazil
3.2 Experimental procedures
3.2.1 Coating of the surfaces
The coating of the surface was obtained by boiling nanofluids with volumetric concentrations of 0.001, 0.01 and
0.1% on the test tube surface. For the coating (deposition), the different nanofluids were inserted on the experimental
apparatus, boiled on the test tube, and then withdrawn. Figure 2 presents images obtained with a Vecco Wiko NT1100
optical profiler of the test tube surface as received from the manufacturer, deposited with SiO2 15 nm and SiO2 80 nm
nanoparticles. The images were obtained for depositions performed with nanoparticles volumetric concentration of
0.1%. It is important to highlight that a new tube was used for each experimental condition characterized by nanofluid
volumetric concentration and nanoparticles dimension.
Figure 2. Images of the internal surface obtained with an optical profiler (10x magnification).
3.2.2 Experimental campaign and analysis
Heat transfer coefficient results were obtained for the following conditions: (i) DI-water for the tube surface as
received from the manufacturer (BBN); DI-water on the coated surface for depositions obtained with nanoparticles
volumetric concentration of (ii) 0.001% (ABN 0.001%); (iii) 0.01% (ABN 0.01%); and (iv) 0.1% (ABN 0.1%).
Before been charged in the circuit, the DI-water (working fluid) was boiled for a period of 30 minutes in order of
eliminating non-condensable gases. The experimental circuit was firstly evacuated down to an absolute pressure of 10
kPa, and then charged with DI-water. The tests were performed for a saturation temperature at the test section outlet of
102 ± 3°C, subcooling at the test section inlet of 25°C, heat fluxes ranging from 100-350 kW/m2, vapor quality at the
test section outlet from 0.01 to 0.5 and mass velocities of 200, 400 and 600 kg/m2s.
The local heat transfer coefficient, h, was estimated according to the Newton’s cooling law, as follows:
)( bulkwall TT
q
h
(1)
The temperature at each one of the five cross-sections with thermocouples was estimated by averaging the
measurements at the top and bottom of the tube external surface. Based on this value for each cross section, the wall
temperature of the inner surface, Twall, was estimated by solving the heat diffusion equation assuming one-dimensional
Proceedings of ENCIT 2016 16th Brazilian Congress of Thermal Sciences and Engineering
Copyright © 2012 by ABCM November, 07-10th, 2016, Vitória, ES, Brazil
heat conduction through the wall, uniform heat generation by joule effect and adiabatic external surface. To estimate the
fluid bulk temperature, Tbulk, firstly, based on the heat flux and the measured temperature and pressure at the test section
inlet, the subcooled region length, the single-phase pressure drop over its length, and the saturation temperature at the
beginning of the saturated region were calculated by solving simultaneously an equation of state relating saturation
temperature and pressure plus single-phase pressure drop and a local energy balance. The overall pressure drop over the
saturated region was then determined by subtracting the single-phase pressure drop from the measured total pressure
drop. After that, a constant pressure drop gradient, given as the ratio of the overall pressure drop over the saturated
region and the corresponding length, was assumed from the beginning of the saturated region until the end of the test
section. Then, the saturation temperature was calculated from the estimated local pressure. The heat flux, q, was
calculated as the ratio between the electrical power supplied to the test section and its internal area based on the heated
length. The electrical power was calculated as the product between the electrical current and the voltage supplied by the
DC power source. The local vapor quality was estimated based on determined by an energy balances over the
corresponding heated lengths.
Temperature measurements were calibrated and the temperature uncertainty was evaluated according to the
procedure suggested by Abernethy and Thompson (1973). Accounting for all instrument errors, uncertainties for the
calculated parameter were estimated using the method of sequential perturbation according to Taylor and Kuyatt
(1994). The experimental heat transfer coefficient error was always lower than 20%. The heat transfer coefficient
average error was 10.6%.
3.2.3 Manufacturing procedure of the nanofluids
The nanofluids were prepared according to the two-steps method, which consists of adding nanoparticles,
(SiO2 nanoparticles with 80 nm or 15 nm diameter) weighed through a digital analytical balance, to a base fluid (DI-
water) and dispersing them through ultrasonication during a period of 30 minutes (Coleparmer CP505). Once prepared,
the nanofluid was loaded to the test facility following the procedure above cited (item 3.2).
4. RESULTS
Figure 3 illustrates the heat transfer coefficient behavior with varying vapor quality for flow boiling of DI-
water on nanoparticles coated tubes. This figure reveals different behaviors according to the nanoparticle size. In
general, the heat transfer coefficient is lower for the surface covered with 15 nm nanoparticles compared to the tube as
commercially available. On the other hand, distinct behaviors according to the mass velocity range are observed for the
heat transfer coefficient on the surface covered with 80 nm nanoparticles compared to the tube without a covering layer.
Considering only the results for DI-water on the tube as received from the manufacturer, it is noted in Figs. 3-
(a), 3-(b) and 3-(c) that the heat transfer coefficient increases with increasing vapor quality. This behavior is typical of
flow boiling heat transfer under predominance of convective effects. On other hand, Fig. 3-(d) shows a practically
constant heat transfer coefficient with increasing vapor quality. Such a behavior is typical of flow boiling dominated by
nucleate boiling effects.
For G=200 kg/m2s and vapor quality higher than 0.06, the heat transfer coefficient differences between the
tube as provided by the manufacturer and the tube with the surface coated with 80 nm nanoparticles are within the
uncertainty range of the heat transfer coefficient measurements regardless of the volumetric concentration. On the other
hand, for the surface covered with 15 nm nanoparticles and for both mass velocities (200 and 600 kg/m2s), the heat
transfer coefficient decreases with increasing nanoparticle volumetric concentration of the nanofluid used in the
covering process. Under low vapor quality conditions, G=600 kg/m2s and covered layer formed by 80 nm nanoparticles,
the nanocoated surface provided higher heat transfer coefficients than the tube without covering. Moreover, under these
conditions, the heat transfer coefficient seems to increase with increasing the nanoparticle volumetric concentration.
It can be figured out from the heat transfer coefficient behaviors displayed in Figs. 3-(b) and 3-(c) that the
deposition of 80 nm nanoparticles on the surface provides an increment of the nucleate boiling effects under low vapor
quality conditions. Moreover, as illustrated in Fig. 3-(c), for G=600 kg/m2s, it seems that the deposition of nanoparticles
on the surface improves nucleate boiling effects and is detrimental to convective effects due to changes on the surface
micro-structure, improving the number of active nucleation sites compared to the original surface. From the results
displayed in Fig. 3-(c), it can be concluded that nucleate boiling effects are enhanced by increasing the nanoparticle
volumetric concentration of the solution employed to obtain the coating.
For the surface coated with 15 nm nanoparticles, it seems that the coating reduces the nucleate boiling effects.
Such a statement is based on the heat transfer coefficient reduction with increasing the nanoparticle volumetric
concentration of the solution used during the deposition process, as shown in Figs. 3-(a) and 3-(d).
Another aspect that should be highlighted and that corroborates the discussion presented in the last paragraph
is the different deposition patterns according to the nanoparticles dimensions as shown in Fig. 2. According to this
figure, the surface texture through the deposition of 80 nm nanoparticles seems almost similar to the commercial tube
(without deposition). On the other hand, a non-uniform texture is observed for the surface with 15 nm nanoparticles.
Proceedings of ENCIT 2016 16th Brazilian Congress of Thermal Sciences and Engineering
Copyright © 2012 by ABCM November 07-10th, 2016, Vitória, ES, Brazil
Therefore, from the analysis of the heat transfer results displayed in Fig. 3, and the difference in the surface texture
before and after nanoparticles deposition, as shown in Fig. 2, it can be concluded that the heat transfer coefficient does
not varies significantly with 80 nm nanoparticle deposition, since the surface texture is kept almost the same and the
thermal resistance generated by the nanoparticle deposition is almost negligible due to its reduced thickness. However,
the deposition of 15 nm nanoparticles changes the surface texture, and consequently the number of nucleation sites. In
fact, the present study agrees with the results of Wen et al. (2011) and Souza et al. (2014). According to these authors,
the effect of the nanoparticle deposition on the heat transfer coefficient is affected by the relative size of the
nanoparticles and surface cavities and the way that they interact in order to obtaining the final surface finishing.
Figure 3. Heat transfer coefficient behavior with varying the vapor quality for a) SiO2 15 nm nanoparticle coated
surface, G=200 kg/m2s; b) SiO2 80 nm nanoparticle coated surface, G=200 kg/m2s; c) SiO2 80 nm nanoparticle coated
surface, G=600 kg/m2s and d) SiO2 15 nm nanoparticle coated surface, G=600 kg/m2s.
5. CONCLUSION
Based on the analyses of the experimental results obtained in the present study, the following conclusions are
presented:
i. In general, the heat transfer coefficient increases with increasing vapor quality for flow boiling in the
tube as commercially available. Such behavior is typical of flow boiling under performance of
convective effects;
ii. For the surfaces covered with 15 nm nanoparticles, the heat transfer coefficient decreases with
increasing the nanoparticles volumetric concentration of the solution used during the deposition
process. For the surfaces covered with 80 nm nanoparticles and low vapor qualities, it seems that the
heat transfer coefficient increases with increasing the nanoparticles volumetric concentration of the
solution used during the deposition process. On the other hand, as the vapor quality increases, the
effect of the nanoparticles volumetric concentration on the heat transfer coefficient seems to become
negligible and the results are within the range of uncertainties of their measurements;
Proceedings of ENCIT 2016 16th Brazilian Congress of Thermal Sciences and Engineering
Copyright © 2012 by ABCM November, 07-10th, 2016, Vitória, ES, Brazil
iii. Finally, it is important to highlight that the deposition of nanoparticles o the surface modifies its
texture, and its heat transfer behavior. Moreover, the intensity of these effects on the heat transfer
coefficient are related to the way that the nanoparticles fills the cavities on the surface and how it
affects the number of nucleation sites and, consequently, the nucleate boiling behavior;
6. ACKNOWLEDGEMENTS
The authors gratefully acknowledge the financial support under contract numbers 2011/13119-0 and 131082/2015-9
given by FAPESP (São Paulo Research Foundation, Brazil) and CNPq (National Council of Technological and
Scientific Development, Brazil) respectively, and the CAPES (Coordination for the Improvement of Higher Level
Personal, Brazil) for the research grant given through the NANOBIOTEC research program. The authors also
acknowledge Mr. José Roberto Bogni for the technical support given to this investigation.
7. REFERENCES
Choi, S. U. S. and Eastman, J. A., 1995. “Enhancing thermal conductivity of fluids with nanoparticles”. In Proceedings
of ASME International Mechanical Engineering Congress & Exposition, San Francisco, CA, USA.
Valfei, S. and Borca-Tasciuc, T., 2014. “Role of nanoparticles on nanofluid boiling phenomenon, Nanoparticle
deposition”. Chemical Engineering Research and Desing, Vol. 92, pp. 842-856.
Wen, D., Corr, M., Hu, X. and Lin, G., 2011. “Boiling heat transfer of nanofluids: The efect of surface modification”.
International Journal of Thermal Sciences, vol. 50, pp. 480-485.
Diao, Y. H., Liu, Y., Wang, R., Zhao, Y. H., Guo, I. and Tang, X., 2013. “Effects of nanofluids and nanocoatings on the
thermal performance of an evaporator with rectangular microchannels”. International Journal of Heat and Mass
Transfer, vol. 67, pp. 183-193.
Fang, X., Wang, R., Chen, W., Zhang, H. and Ma, C., 2015. “A review of flow boiling heat transfer of nanofluids”,
Applied Thermal Engineering, vol. 91, 1003-1017.
Moreira, T. A., Nascimento, F. J., Ribatski, G., 2015. “Flow boiling heat transfer coefficient of DI-water/SiO2
nanofluid inside a 1.1 mm round microchannel”. In Proceedings of ASME International Conference on
Nanochannels, Microchannels and Minichannels, San Francisco, CA, USA.
Souza, R. R., Passos, J. C. and Cardoso, E. M., 2014. “Influence of nanoparticle size and gap size on nucleate boiling
using HFE7100”, Experimental Thermal and Fluid Science, vol. 59, pp. 195-201.
Tibiriçá, C. B. and Ribatski, G, 2014. “Flow patterns and bubble departure fundamental characteristics during flow
boiling in microscale channels”, Experimental Thermal and Fluid Science, vol. 59, pp. 152-165.
8. RESPONSIBILITY NOTICE
The authors are the only responsible for the printed material included in this paper.
ResearchGate has not been able to resolve any citations for this publication.
Conference Paper
Full-text available
The scope of the present paper is the evaluation of the heat transfer coefficient during flow boiling of DI-water/silica nanofluid inside a 1.1 mm ID tube. The experiments were performed for nanoparticles and DI-water with both having thermal conductivities of the same order of magnitude (kDI-water = 0.6 W/mK, ksilica = 1.4 W/mK). So, it was possible investigating the effect of the nanoparticles on the heat transfer coefficient under condition of negligible thermal conductivity enhancement. Experiments were carried out for mass velocities of 200, 400 and 600 kg/m²s, heat fluxes from 60 kW/m² to 350 kW/m² and nanoparticles volumetric concentration of 0.001%, 0.01% and 0.1%. Moreover, flow boiling heat transfer data under similar experimental conditions were obtained for DI-water without nanoparticles before and after performing each nanofluid test. The experiments were performed at the same test section according to the following sequence: i) DI-water, ii) 0.001% vol. nanofluid, iii) DI-water, iv) 0.01% vol. nanofluid, v) DI-water, vi) 0.1% vol. nanofluid, and vii) DI-water. Such procedure was adopted in order to evaluate the influence of the deposition of nanoparticles at each concentration on the heat transfer coefficient. For single-phase flow the HTC decreases as the experiments were performed. The thermal resistance due to deposition of nanoparticles is relevant to the heat transfer coefficient for single-phase flow of nanofluids inside microchannels. The flow boiling HTC decreases with increasing the nanoparticle volumetric concentration from a concentration of 0.001%. Based on the flow boiling HTC behaviors for tests with pure DI-water before and after the nanofluid tests, the fact that the HTC decreases with increasing the nanoparticle volumetric concentration is not explained only by the deposition on the surface of a nanoparticle layer. Tests for pure DI-water before the tests of nanofluids (BBN condition) and after all the nanofluids tests (ABN 0.1% condition) presents similar heat transfer coefficients, despite the deposition of a nanoparticle layer on the surface.
Conference Paper
Full-text available
Low thermal conductivity is a primary limitation in the development of energy-efficient heat transfer fluids that are required in many industrial applications. In this paper we propose that an innovative new class of heat transfer fluids can be engineered by suspending metallic nanoparticles in conventional heat transfer fluids. The resulting {open_quotes}nanofluids{close_quotes} are expected to exhibit high thermal conductivities compared to those of currently used heat transfer fluids, and they represent the best hope for enhancement of heat transfer. The results of a theoretical study of the thermal conductivity of nanofluids with copper nanophase materials are presented, the potential benefits of the fluids are estimated, and it is shown that one of the benefits of nanofluids will be dramatic reductions in heat exchanger pumping power.
Article
In this study, the effect of Al2O3-R141b nanofluids as the working fluid on the thermal performance of micro-channel surfaces at different pressures and nanofluid particle concentrations were experimentally investigated. The operational pressures and volume concentration of nanoparticles were varied among 0.86 x 10(5), 0.91 x 10(5), 0.96 x 10(5), 1.0 x 10(5), and 2.0 x 10(5) Pa, and 0.001, 0.01, and 0.1 vol%, respectively. The experimental results showed that the operational pressure and volume concentration of nanoparticles have significant effect on the heat transfer characteristics for nanofluids of Al2O3/R141b. For operating pressure in the range 0.86-0.96 x 10(5) Pa and nanofluid concentrations of 0.001 and 0.01 vol%, the corresponding heat transfer coefficients were larger than those of the base fluid. For the concentration of 0.1 vol%, when the superheat degree was higher than that for the pure fluid, the heat transfer coefficient was lower. At high pressures of 1.0 and 2.0 x 10(5) Pa, for the concentration of 0.1 vol%, heat transfer deteriorated for the entire range of measured data. Under the same operating pressures, for the concentrations of 0.001 and 0.01 vol%, the heat transfer enhancement was not apparent. Further, the heat transfer characteristics of the nanofluids for Al2O3-nanoparticle-covered surfaces with rectangular microchannels, which were produced by the evaporation of nanofluids with various concentrations ranging from 0.001 to 0.1 vol%, were experimentally studied. The heat transfer curves for the nanoparticle-covered surfaces were compared with those for nanofluids on bare surfaces, and the results demonstrated that the nanoparticle covering has a strong influence on the heat transfer behavior.
Article
Suspended nanoparticles inside the nanofluids can modify the characteristics of heated surfaces and the physical properties of the base liquids, offering a great opportunity to optimize boiling heat transfer. This paper reviews the mechanisms of nanoparticle deposition and the effects induced by deposited nanoparticles on surface roughness, force balance at the triple line, surface wettability, active nucleation site density, receding and advancing contact angles, boiling heat transfer coefficient and critical heat flux. Both enhancement and deterioration effects on boiling heat transfer coefficient and critical heat flux have been discussed. Most of the existing experimental data confirms the enhancement of critical heat flux using alumina nanofluid, however there is no consistency about its boiling heat transfer coefficient.
Article
This paper presents an experimental investigation into the fundamental characteristics of flow boiling in microscale channels based on diabatic high-speed flow visualizations. Experiments were conducted with R134a and R245fa refrigerants flowing in a 0.40 mm circular horizontal channel for mass velocities ranging from 100 to 900 kg/m2s and heat fluxes of up to 226 kW/m2. Flow images were captured at recording speeds of up to 100,000 frames/s. Results for bubble departure diameter and frequency, bubble growth ratio, slug frequency and velocity, flow pattern transitions, characteristics of the liquid film and liquid-vapor interface are provided. The experimental data obtained are carefully analyzed, discussed and compared against previous results for tubes of 1.00 and 2.00 mm internal diameter. Predictive methods available in the literature for bubble departure diameter and frequency are evaluated by comparing their predictions against the data obtained in the present study. New bubble departure diameter and frequency correlations are proposed for small channels. The following conclusions can be drawn from the present study: (i) bubbles can detach from the wall with diameters much smaller than the tube diameter; (ii) the bubble growth process has a square root time-dependence; (iii) two different methods for estimating the average surface heat flux based on flow boiling videos have been developed; (iv) bubble active nucleation sites are observed for all flow patterns; (v) buoyancy effects are still present for a 0.40 mm tube, and (vi) six different sources of vapor-liquid interface oscillations have been identified.
Article
This work reports a comparative study of nucleate boiling heat transfer with aqueous alumina nanofluids on two specially designed surfaces. The detailed surface characterization before and after boiling reveals that the modification of heating surface geometries is mainly responsible for many contradictory results reported in literature. The enhancement or deterioration of boiling heat transfer by nanofluids is dependent upon different surface modifications that strongly affected by the relative size between particles suspended in the liquid and the heating surface geometry, and their interactions. The surface modification by nanoparticles is an inherent feature of nanofluids, and would occur each time after boiling. The experimental results would be affected by the number and frequency of the usage of boiling surfaces.
Role of nanoparticles on nanofluid boiling phenomenon, Nanoparticle deposition
  • S Valfei
  • T Borca-Tasciuc
Valfei, S. and Borca-Tasciuc, T., 2014. "Role of nanoparticles on nanofluid boiling phenomenon, Nanoparticle deposition". Chemical Engineering Research and Desing, Vol. 92, pp. 842-856.