The Kobe earthquake is considered to be one of the most devastating and costly natural disasters in recent history considering the number of buildings destroyed, the number of people killed and injured, the size of the affected area, and the extent and severity of damage to a wide range of structural types. As a result, important questions have been raised about earthquake preparedness, disaster response, seismic design and codes of practice, and upgrading of earthquake-resistant structures. This paper presents an overview of this earthquake, investigates the extent and types of damage caused, studies the factors behind each type of damage, and highlights important lessons learnt from this earthquake. Protective measures and future research that should be undertaken in Japan, and all countries that are at seismic risk, are recommended in order to reduce damage and casualties in future seismic events.
Content may be subject to copyright.
1
British Geological / Geotechnical Society
BGS Special Publications, 1996
Keynote Paper in BGS Intl Conference, Coventry, 1995
KOBE EARTHQUAKE Lessons Learnt
Philip Esper, University of Westminster
Eizaburo Tachibana, Osaka University
ABSTRACT
The 1995 Kobe earthquake is considered to be one of the most devastating and
costly natural disasters in recent history considering the number of people killed
and injured, the number of buildings destroyed, the size of the affected zone, and
the extent and severity of damage to a wide range of structural types. As a result,
important questions have been raised about earthquake preparedness, disaster
management and response, seismic design and codes of practice, and retrofitting
of existing structures. As a member of the UK Earthquake Field Investigation
Team (EEFIT), the first author was involved in the immediate aftermath of the
disaster and his work covered both investigating the damage caused to the built
environment, and implementing strategies in managing the consequences of the
disaster. This paper gives an overview of the disaster, highlights important
lessons learnt, and recommends protective measures.
2
1. INTRODUCTION
Prior to this disaster, Kobe was the second largest port of Japan with a population
of around 1.4 million that lived on a narrow 4 km wide strip of land between
Osaka Harbour and Rokko Mountains (see Fig.1). The Kobe earthquake
occurred at 5:46 am (local time) on Tuesday 17 January 1995 and is considered
to be the greatest natural disaster to have struck Japan since the 1923 Great
Kanto earthquake that devastated large areas of Tokyo and Yokohama and killed
approximately 143,000 people [Esper and Tachibana, 1995].
The Kobe earthquake was assigned a magnitude of 7.2 by the Japan
Meteorological Agency (JMA) and its epicentre was located approximately 20 km
South-West of the Kobe city centre just North of the Awaji island (identified by a
star in Figs.1). 89% of the casualties from this earthquake were caused by
buildings collapse as most people were asleep when the earthquake struck.
Nearly 55,000 houses collapsed and approximately 32,000 were partially
destroyed. These figures exclude damage caused by fire that exceeded 7,500
houses. It wrecked elevated roadways and railways, initiated landslides and
destroyed ports and harbour facilities. As a result of this severe damage and fire,
over 5,400 people were killed, as many as 34,000 were injured, and around
350,000 were made homeless. The official estimates, that were released one
week after the earthquake, of direct losses in the Hyogoken prefecture alone
exceeded $100 billion; later estimates have reached $200 billion, indirect losses
undoubtedly would raise the total amount even more.
2. GEOLOGICAL ASPECTS
Japan sits on the intersection of four tectonic plates that are under constant
seismic risk. Kobe, which is located relatively far from the main tectonic collision
zones, was considered - before this earthquake - as less seismically active
3
compared to other areas in Japan such as Tokyo. The earthquake on 17th
January, however, was not along the major inter-plate faults but rather on the
intra-plate fault zone (see Fig.2) that spread within one of these four plates.
Based on the distribution of the aftershocks and teleseismic waveform modelling,
it is postulated that the strike-slip rupture was bilateral from the hypocenter, with a
total length of between 30 and 50 km. The epicentre of magnitude 7.2 event was
located approximately 20 km south-west of the city centre of Kobe in the strait
between Awaji Island and the south central part of Honshu, the main island in
Japan. The rupture had the following characteristics [Esper and Tachibana,
1995}:
Focal Depth: DF = 14.5 km
Fault Area: S = 40 X 10 km2
Relative Displacement: U = 2.1 m
Duration of main rupture: T = 11 sec
The duration of the earthquake was measured at the Observatory at just less
than 15 seconds. Ground motions record at the Matsumuragumi Technical
Research Centre (MTRC) which is located approximately 35 km from the
epicentre showed a peak ground accelerations at foundation level of 272 gal
(0.28g) in the N-S direction, 265 gal (0.27g) in the E-W direction, and 232 gal
(0.24g) in the U-D (vertical) direction. This shows that the peak vertical
acceleration was approximately 0.9 times the peak horizontal acceleration which
exceeded typical values observed in past earthquakes.
3. GEOTECHNICAL ASPECTS
The main geotechnical aspects associated with this earthquake included the
following:
4
a) Large ground movements associated with fault ruptures in Awaji Island;
the maximum movement observed was 1.70 m of right lateral strike slip
and 1.30 m of vertical slip.
b) Massive Soil liquefaction which was observed in many reclaimed lands in
Osaka Bay including two man-made islands; Port Island (8 km2) and
Rokko Island (6 km2). Soil liquefaction was also observed along the port
of Kobe and caused extensive damage to many industrial and port facilities
such as tanks, wharves, quay walls, cranes, and the collapse of the
Nishinomiya Harbour Bridge girder.
c) Several underground subway stations constructed by cut-and-cover
suffered major damage to their reinforced concrete pillars.
d) Numerous landslides and rockfalls resulted along the hillside of
Nishinomiya area; in Nikawa, a landslide buried 12 houses and 34 people.
4. DAMAGE TO BUILDING STRUCTURES
Table (1) shows statistics of the damage caused by this earthquake in terms of
both residents and houses. These quantities were based on a statistical data of
an inspection made before 20th January 1995 and collected by the Architectural
Institute of Japan (AIJ), Kyoto University, Osaka Institute of Technology (OIT),
Fukui University and Hiroshima University. Most of the severe damage in and
around Kobe was concentrated along a narrow band 1-2 km wide and
approximately 30 km long, beginning at the northern tip of Awaji Island and
extending across the Akashi channel in the E-NE direction along the coastline
(see Fig.2).
The majority of the collapsed buildings were unbraced, or lightly braced, one- and
two-storey post and beam traditional wooden houses with heavy clay tiled roofs
5
(see Fig.3). These are known as Shinkabe and Okabe. Little nailing is used in
either types and they rely on wood joinery for connections. This type of heavy
roofing has been widely used in Japan as it provide excellent resistance to the
strong gusty winds of typhoons which frequently sweep across the country.
Structural damage occurred also in reinforced concrete (see Fig.4), steel, and
composite structures. Generally, no material type was immune from damage, but
most of the severe damage occurred in non-ductile steel and concrete structures
that were built prior to the implementation of requirements for ductile detailing.
As per data collected in the year 1989, timber, steel, concrete, and steel-encased
reinforced concrete (referred to as SRC) account for approximately 30%, 40%,
20%, and 10% respectively of all square meters of construction in Japan [AIJ,
1995]. With respect to modern buildings, it should be noted that those designed
according to the 1981 Building Standard Law (BSL) - which mandated ductile
detailing for the first time - generally performed well. A recent study by
Ohbayashi Corporation on the performance of residential and office buildings
constructed by this Corporation in the Kobe earthquake is summarised in Table
(2). Such a global evaluation of seismic performance of buildings must be used
to evaluate the effectiveness of design codes.
As far as seismic resistance is concerned, an important revision to the Japanese
Building Code (JBC) took place in 1971, when requirements necessary to
enhance the shear behaviour of reinforced concrete members were first
considered. A major overhaul of the JBC then occurred in 1981, when a two-
level design procedure was implemented, along with requirements to explicitly
consider ductile behaviour. These two periods provide important milestones in
the Japanese history of earthquake-resistant design.
Over 100 reinforced mid-rise buildings that were constructed during the 1960’s
and 1970’s have failed, in many cases catastrophically. Most failures appear to
have been shear failures of columns that had very light transverse reinforcement
6
(spacing of stirrups exceeded 200 mm in many cases) as shown in Fig.3.
Another reason is that stirrups in columns, quite often, were not welded at the
ends, as is usually the case in Japanese design and construction practice. This
indicated bad supervision of works at the time of construction which was
supported by other examples such as; some fillet-welds that were encountered
during investigation works on some buildings were found to be specified as butt-
welds on design plans.
A number of mid-height single storey pancake collapses were observed with the
1960’s vintage eight-storey Kobe City Hall being the best example (see Fig.5).
While this building sustained a complete collapse of the sixth floor, the
neighbouring 1980’s vintage 30-story New City Hall was undamaged. The soft
storey collapse of the sixth floor in the former building, was due to the fact that
this floor formed a transition storey from an SRC system to a RC system. This
type of construction was common in Japan until 30 years ago, purely for
economy. Until this earthquake occurred, this type of collapse has never been
observed previously.
5. DAMAGE TO INFRASTRUCTURE
Many transportation facilities failed and were out of operation for a long period of
time. Railway tracks snapped in many locations, and trains flipped on their sides.
Many decks and girders of elevated roadways and railways shifted from their
original location or even dropped to the ground. The Kobe city main highway
disintegrated in many places. Many modern bridges, such as the Akashi
Suspension bridge, however sustained no or little damage.
In the case of the elevated Hanshin Expressway - which links Kobe, Osaka and
beyond - huge single hammerhead reinforced concrete piers, that were holding
up the girders, broke off at their bases failing in shear and / or bending resulting
in a 500 m segment being tipped onto the ground (see Fig.6). This elevated
7
segment was constructed in 1968-1969 under older seismic provisions and
scheduled for retrofitting in the future by the Hanshin Expressway Public
Corporation (HEPC). Also, at this location of the elevated expressway, the
superstructure changed from steel to concrete increasing the mass of the
structure, and hence the earthquake forces acting on it, sufficiently to push this
section over and cause to collapse transversely. Lack of enough transverse
reinforcement was also observed in some of the collapsed columns.
Rail facilities were particularly hard hit in this earthquake. Three main lines; JR
West, Hankyu, and Hanshin that run in general on elevated embankment all
sustained embankment failures, overpass collapses, distorted rails and other
severe damage. In Kobe, the Shinkansen (Bullet Train) runs generally in a tunnel
through Rokko Mountain. At the east portal of the tunnel, the line is carried on an
elevated viaduct, built in the 1960’s. For a length of three kilometres, this viaduct
was severely damaged with a number of the longer spans collapsing due to shear
failure of the supporting columns.
Electric power and telecommunications performed relatively well in the
earthquake with little damage and reduction in service. Gas and water supply,
however, were not restored fully until around the middle of March. In spite of the
sincere efforts that both Kobe Water Department (KWD) and Osaka Gas
Company (OGC) made to implement anti-seismic measures to prevent such
service interruptions from occurring, 725,000 customers were without gas supply
and 29,000 were without water until around the middle of February. The water
and gas system sustained numerous breaks in their underground pipelines and
distribution systems with general lack of service in the cities of Kobe, Ashiya and
Nishinomiya.
8
6. LESSONS LEARNT
Tremendous damage was observed in this earthquake, some of which has not
been encountered in past earthquakes. The following important lessons were
recognised [Esper and Tachibana, 1995]:
a) Local site conditions had a major impact on the level of shaking. It is,
therefore, vital to identify the influence of subsurface soil conditions on the
amplification of ground motion.
b) Amplification of vibration due to topographic irregularities or / and the
presence of soft soil underlying this area was a major factor in increasing
the scale of damage to building structures and infrastructure.
c) Reinforced geotextile walls along the JR railway line in Higashi-Nada
district performed relatively well compared to the level of damage to the
surrounding site.
d) The failure of the Daikai station of the Kobe Rapid Transit Railway (KRTR)
is highly significant because it is the first instance of severe earthquake
damage to a modern tunnel for reasons other than fault displacement and
instability near the portal.
e) The peak vertical ground acceleration was approximately equal to the
peak horizontal acceleration, as recorded in some stations (e.g. MTRC).
This is much higher than what was observed in past earthquakes.
f) Matsumuragumi Technical Research Centre (MTRC) and Computer
Centre of Ministry of Post and Communications (CCMPC) are the only two
buildings in the affected area (approximately 35 km from the epicentre)
that are founded on base-isolators. The former was visited by the author
9
and no signs of damage exist at all throughout the whole building. The
same was reported by others on CCMPC building.
g) While hospitals are intended to provide relief to disaster victims, the NHK
television news reports [NCE, 1994] showed victims being carried away
from a damaged hospital after the earthquake. This type of structures
must be designed with greater resistance than ordinary structures.
h) Most failures in reinforced mid-rise buildings that were constructed during
the 1960’s and 1970’s appear to have been shear failures of columns that
had very light transverse reinforcement and / or unwelded stirrups. This
indicated bad supervision of works at the time of construction which was
supported by other examples such as; some fillet-welds that were
encountered during investigation works on some buildings were found to
be specified as butt-welds on design plans.
i) A report in 1990 presented to the Hanshin Expressway Corporation (HEC)
showed that, chemical deterioration inside the concrete pillars has been
taking place for some time due to what is known as alkali-aggregate
reaction causing the pillars to crack [NCEER, 1995]. Although this was
acted on immediately with regular maintenance schemes involving the
injection of a special resin into the cracks to stop deterioration, it was
reported, after the earthquake that the strength of the pillars immediately
before the earthquake were only around 42% of their original strength.
7. CONCLUSIONS AND RECOMMENDATIONS
It has to be made clear that Kobe’s destruction was not a failure of Japanese
technology. Evidence was shown, that the majority of the buildings designed
according to the present Japanese codes sustained little or no damage [EEFIT,
1998]. The fact of the matter is not only, however, investigating which buildings
10
performed well and what code they satisfied. Each earthquake is unique. What
really matters is what engineers and decision makers, such as politicians, should
learn from this recent disaster so that future hazards can be made less damaging.
The following recommendations are made:
a) There is an urgent need to establish reliable and cost-effective techniques
to evaluate, repair, strengthen / retrofit existing structures and buildings in
Japan (and in affected countries in the future) that suffered minor or
localised damage. This particularly applies to structures, buildings and old
wooden houses, elsewhere in Japan, that were constructed before current
seismic design regulations were implemented.
b) A global evaluation of seismic performance of buildings must be used to
evaluate the effectiveness of design codes, in all countries that are at
seismic risk.
c) Current Japanese seismic codes do not consider importance factors, as
the design and construction of Kobe port facilities indicated. A review of
these codes is now considered necessary.
d) Higher values of peak vertical acceleration was experienced in this
earthquake. This was also suggested by certain types of damage
observed in various structures. Hence, a review of all design codes of
practice is needed in order to take this factor into account.
e) Soil-foundation-structure interaction study should not be restricted to
heavy or special structures, such as nuclear power stations. Evidence
was provided by this earthquake that this interaction was significant in the
seismic behaviour of different types and sizes of structures.
f) Structures that are required to provide essential services after disasters,
such as hospitals and fire stations, must be designed with greater
11
resistance to seismic forces than ordinary structures. In this respect,
methods such as base-isolation [Esper et al, 2004], should be taken more
seriously as a powerful means for enhancing the seismic performance of
these structures.
g) Based on the Californian Northridge earthquake damage [Ref.8] and on
the author’s experience with bomb damaged buildings [Esper and Keane,
2004] in the City of London, hidden (undetected damage) would have
resulted following this earthquake, particularly in steel and SRC buildings.
A need to establish consistent methods for estimating the extent of
damage and the residual strength of these / similar structures is essential
in order to determine if these structures have the capacity to withstand
future earthquakes.
h) Construction on fill material needs to be re-examined along with the
phenomena of soil liquefaction. Reliable methods and techniques should
be used to control settlements of structures founded on fill materials.
i) Pancake collapse, or soft storey collapse, in building structures was mainly
due to using SRC for the lower storeys and RC for the upper storeys. This
formed a discontinuity in construction material and column sizes at the
level of transition, forming a brittle weak region in the building. Research
is needed to quantify the damage exhibited by these structures using
proper dynamic response analyses with models representative of these
damaged structures. The results of this study, then, should be fed back to
the seismic design codes of practice.
j) Good supervision and maintenance are two important factors that should
be maintained during the construction stage and throughout the intended
life of the structure. This will ensure that the seismic resistance of the
structure is not impaired from, at least, what it was designed to be.
12
REFERENCES
Architectural Institute of Japan (AIJ), Preliminary Reconnaissance Report of
the 1995 Hyogoken-Nanbu Earthquake, Edited by: M. Nakashima and M.
Bruneau, DPRI, Kyoto University, Kyoto, 1995.
National Centre for Earthquake Engineering Research, NCEER Response,
January 1995 special issue, State University of New York at Buffalo, New York,
1995.
New Civil Engineer (NCE), 29th September 1994 edition, UK.
13
Table (1): Damage Statistics in Hyogo, Osaka and Kyoto Prefectures:
Impact on
Residents
Damage to Houses
Deaths
Missing
Due to Ground Shaking
Collapse
Sever
e
Minor
Destr
oyed
Damaged
Hyogo
Prefecture
5394
2
81,206
62,82
6
7,119
337
Kobe city
54,949
31,78
3
7,046
331
Nishinomiya
17,716
13,47
4
48
4
Ashiya
2,543
1,519
13
2
Takarazuka
1,339
3,718
2
Awaji
73
583
Osaka
Prefecture
18
881
5,190
32,61
7
Osaka city
12
190
1,785
8,759
Toyonaka
4
654
2,842
Kyoto
Prefecture
1
3
3
1,109
Kyoto city
1
500
14
Table (2): Performance of Buildings Constructed by Ohbayashi Corporation:
Green Tags
(Negligible
damage)
Yellow Tags
(Moderate
Damage)
Red Tags
(Severe Damage)
Pre-1971 Old
Seismic Design
Code
42 %
22 %
36 %
1972-1980
Transitional
Period
72 %
17 %
11 %
Post-1981
New Seismic
Design Code
84 %
10 %
6 %
15
Fig. 1: Map of the affected area - Kobe and vicinity. (P: Port Island, R: Rokko
Island).
16
Fig. 2: Main shock epicenter, active faults and aftershock zone. (Source: DPRI,
Kyoto University).
17
Fig. 3: Collapse of timber houses.
18
Fig. 4: Collapse of a reinforced concrete column inadequate transverse
reinforcement.
19
Fig.5: Pancake (or soft-storey) collapse of the sixth floor of the Kobe City Hall.
20
Fig.6: The collapse of the Elevated Hanshin Expressway.
21
Fig.7: Base isolation system.
... For each of them, the impact of disruptions on the traffic control are highlighted. The Kobe earthquake and resulting fires and liquefaction led to great devastation of buildings, roads, railways, the harbour and people (Esper and Tachibana 1998). The traffic control was impacted by the loss of major expressways that connected Kobe with other parts of the country (Iida et al. 2000). ...
Article
Making cities disaster resilient is important as proven by the increased number of city networks such as 100 Resilient Cities. The major difficulty on this trajectory is the interrelated components in urban systems that influence each other and increase uncertainty in risk assessment and management. Therefore, this study analyses the potential road blockages that impact traffic control using a multi-hazard risk assessment for the historical peninsula of Istanbul, Turkey. To support the communication of the causes of such potential disruptions, a 3D city model is created for the visualisation and analysis of the consequences from a disaster. For the socioeconomic, physical and systemic vulnerability and risk assessments, the additive normalization indicator-based approach is used. Besides, to determine the building vulnerability and damage grades, the EMS-98 Macroseismic method is applied. This study found that the socioeconomic vulnerability is high to very high which could contribute to emergent behaviour causing traffic congestions and communication issues. In addition, most buildings have been determined to be ‘very heavily damaged’. Consequently, there is high risk for road blockages in the narrow streets within the case study area, while the roads themselves have low risk to damage. The usage of 3D modelling techniques for visualisation and analysis improves understandability, visual problem identification and support decision making for mitigation strategies in case of road blockages.
... For steel frame structures, we can ensure that they can withstand earthquakes much larger than the design earthquake without collapsing by increasing their flexibility. For example, in the Kobe earthquake in Japan [10,11], the ground motion in some areas far exceeded the rare design earthquake (400Gal), and the structures were severely damaged. However, they did not collapse, and human safety was guaranteed [12]. ...
... Some past earthquakes have resulted in severe damage to reinforced concrete (RC) structures with substandard lap splices [1][2][3][4]. Old buildings without seismic detailing commonly used lap splices at columnfooting junctions. ...
Article
Full-text available
Bond splitting failure of substandard lap splices have caused extensive damage to many structures during earthquakes. Existing methods to strengthen substandard lap splices primarily involve wrapping the substandard lap spliced regions with jackets possessing mainly in-plane stiffness. Hence, the efficiency of such techniques is compromised due to the lateral bulging of concrete and flexural bending of jackets. This study investigated hollow steel section (HSS) collars which offer axial and flexural stiffness in mitigating splitting failures associated with lap splices not conforming to current design codes. Three lap splice lengths, mainly 20, 28, and 35 times the bar diameter (db) were studied. Experiments were conducted on 19 beams subjected to four-point bending, with substandard lap splices within the constant moment region. Test variables involved the lap splice length, concrete cover, and spacing of HSS collars. Results revealed that HSS collars successfully prevented splitting failures resulting in ductile behavior. It was found that the bond stress of the lap-spliced bars increased till the onset of their yielding. Beyond that, the bond stress was maintained close to their peak value in the beams sufficiently confined by HSS collars. By applying HSS collars, improvements in the bond strength for beams with 20db lap splices were evident. The control beams having longer lap splice lengths exhibited yielding, and the improvement in their bond strength was limited despite showing ductile behavior. In order to capture the contribution of HSS collars to the improvement from brittle behavior to ductile behavior, the interfacial fracture energy was also used instead of the bond strength alone. An equation for the increase in the interfacial fracture energy due to the confinement by HSS collars was obtained using nonlinear regression. This equation was utilized to determine the required confinement ratio of HSS collars for a given substandard lap splice. The required confinement ratios of HSS collars obtained from the proposed equation were found to agree with the experiment while overestimation was found in some cases..
... The official estimates that were released one week after the earthquake for direct losses in the Hyogoken province alone exceeded $100 billion; later reached $200 billion, indirect losses undoubtedly would raise the total amount even more. [60] Analysis has been conducted using ground acceleration record of Japan meteorological agency receiving station. ...
Thesis
Full-text available
Rwanda’s population growth and density to a small area are increasing very fast; the increase in urbanization and population growth rate pushed the government to devise modern ways of optimal land use to ensure sustainable growth. High-rise buildings construction is being promoted as a response to the high rate of urbanization and land shortage. To ensure that these newly developed structures in Rwanda are seismically safe and more resilient, base isolation using friction pendulum bearing has been suggested as a sustainable solution in this study. This thesis's aim was to analyze the seismic response of building structures isolated with a single friction pendulum bearing while subjected to earthquake ground motion taking Rwanda as the case study. Keywords: base isolation, friction pendulum bearing, seismic resilience, seismic design
... In this investigation, earthquake acceleration time history of 1995 Kobe earthquake (M w ¼ 6.8) is adopted as input acceleration time history. This earthquake occurred in the intraplate region of Japan similar to the region of this study (Toda et al. 1997;Esper and Tachibana 1998). Moreover, the magnitude of this earthquake is similar to the average magnitude of the earthquakes produced by the sources of the study region. ...
Article
In India, the coastline of Gujarat is known to have a high potential for offshore wind energy. However, the region is highly seismically active with large magnitude earthquakes experienced in the past. The aim of the work is to investigate the site-specific response of an offshore wind turbine (OWT) for assessment of suitability of installation of OWT along the Gujarat coast. Seismic hazard analyses of 44 sites are performed using deterministic approach and response spectrum matched acceleration time histories at all these sites are obtained. Monopile for the wind turbine is designed considering a two-layered soil profile. As per specifications of National Renewable Energy Laboratory (NREL), three-dimensional finite element model of 5MW OWT along with the soil domain is developed in the software ABAQUS considering material nonlinearity. Earthquake time histories combined with wind and wave load are being employed for the analyses. It is observed that the sites lying between Kachchh and Saurashtra regions are most vulnerable whereas sites along the western coast of Saurashtra are found to be least vulnerable. Further, seismic fragility curves for the OWT are derived for different damage states in order to evaluate the probability of damage under various seismic scenarios.
... Wooden structure damaged in the Great Hanshin earthquake[9]. ...
Article
Full-text available
Wood is preferred as building material in earthquake zones thanks to its lightweight. In countries with high seismic activity, wooden construction systems are required to be resistant to lateral and vertical loads. In traditional architecture, lateral load resistance is ensured with filled and unfilled walls which are strengthened with braces. In present day lateral load resistance is ensured with wooden shear walls formed by sheathings covered on the wall frame. Wooden shear walls may contain openings such as windows, doors and service channels. These types of openings reduce rigidity in wooden shear walls. The opening ratio, opening location, sheathing thickness and connection types have an impact on the lateral load bearing capacity of shear walls. This study investigates the use of two types of wooden shear walls with different-layout openings which were modelled with plywood sheathing material. For the purposes of this study, lateral load bearing capacities were calculated for both types of sheathing material of different thicknesses. The results are presented in tables by comparing the calculated capacity increase to the increase in weight. Cite this article as: Demirkıran EK, Gür NV, Ökten MS. Effect of opening layout and sheathing on lateral load bearing capacity in wooden shear walls. J Sustain Const Mater Technol 2021;6:2:70-80.
Article
Full-text available
An earthquake is a fatal natural disaster that occurs suddenly without any prior signal. Every year the world faces many earthquakes with magnitudes varying from low to high. The uncertain nature of earthquakes makes it almost impossible to predict the exact time of occurrence. So, it is necessary to take precautionary steps before an earthquake hits. To take preventive measures, a proper study of tectonic plates and faults must be done to gain insight into the study area's susceptibility. Due to the geological characteristics and tectonic plate activity, Bangladesh risks facing an Earthquake. Every year, Bangladesh also faces some number of earthquakes of different magnitude. This study analyzes the earthquake events in different fault zone of Bangladesh in the last 49 years. The study showed that the Tripura Fault and Shillong Plateau are the most active among the five major faults. The frequency of these faults is higher than the other ones. Though the past earthquake magnitudes were small, it is still concerning that the Tripura fault and Shillong plateau show much more frequent seismic activities that may indicate a bigger earthquake incident in the near future. The epicenter depth of most earthquakes is within 40 km from the surface, which is a concerning issue because most earthquakes are shallow earthquakes that tend to have more damaging properties than deep ones.
Thesis
Seismic hazard and building vulnerability are the main components for seismic risk assessment. In this thesis, soil characterization for the urban area of Nador city and surrounding areas has been presented to assess the regional and local seismic hazard, in terms of PGA and amplification respectively. The vulnerability of existing buildings in Nador was also assessed in terms of capacity and performance. The first part deals with the study of the site effects using the H/V experimental method, in terms of fundamental frequency and amplification. The H/V curves show clear single peaks with large amplitudes (> 2), while no amplification is observed in rocky soils, except for some small areas where weathered soils exist. The results obtained from the measurements are compared with the H/V of the 25 January 2016 earthquake recorded in two stations, showing similar results. The seismic vulnerability index has also been estimated, showing that the areas where two different layers exist are the most vulnerable (> 20) due to the high impedance contrast. The ground response analysis was performed taking into account the shear wave velocity (Vs). A seismic hazard map for the area surrounding the city of Nador is derived in terms of PGA for a return period of 475 years for the rocky soil type (Vs30 greater than 760 m/s) giving a PGA value of 0.14g. On the other hand, the seismic hazard map including site effects is obtained by including the Vs30 values. A procedure using the results of the seismic hazard disaggregation for the rocky soil in terms of PGA with a 10% probability of exceedance is developed to derive the envelope function parameters (duration, level and rise time) which are the basis for the generation of the Eurocode 8 artificial accelerogram. The soil response analysis is carried out using a linear equivalent model on three geotechnical profiles. The results obtained from the site response analysis clearly show the amplification in the silty-clay soil as the amplification obtained in the silty-gravelly soil, while there is no significant amplification obtained in the volcanic rocks. The fundamental frequency is in the range of 1.4 to 2.8 Hz while the maximum amplification factor observed in Nador is 3.5. Seismic vulnerability was assessed for reinforced concrete buildings representing a large number of buildings in Nador. The capacity spectra were developed from the Pushover analysis for the building stock of the city. The investigation of the buildings took into account different levels and parameters, such as the age of the building and the type of structure. The designed model is considered for gravity loads and the non-linear analysis was performed for building models according to ATC-40. The building performance is also studied using the capacity spectrum and the demand curve, which is determined according to the site conditions. In general, the results show that buildings in Nador do not have similar stiffness in terms of displacement, even in terms of code levels or height. The capacity curves show that the capacity level increases with increasing building height and on the other hand demonstrate the corresponding safety within a certain plasticity limit. The variation of the performance point shows that buildings for lower codes behave inadequately and need to be strengthened to avoid severe damage in future seismic events. These studies are considered as an asset for the seismic risk of the city, for the planning of urban development in terms of defining appropriate areas for building projects. On the other hand, the availability of these vulnerability models is a powerful tool for urban planners and structural engineers to assess and improve the capacity of buildings.
Article
Seismic site effects are related to the local lithology, which modulates seismic waves and can enhance their amplification. For this reason, the horizontal-to-vertical ratio (H/V technique) was used to characterize them in the urban area of Nador. Ambient noise was measured at 190 different sites in order to characterize the sedimentary deposits from a seismic point of view, with further reference to 53 available geotechnical boreholes. The first investigation on site effects in Nador city, presented in this study, gives fundamental frequency values between 2.1 and 5 Hz and an amplification factor range between 2.5 and 11.4. No amplification is found in rock soils except for some small areas where weathered soils exist. The obtained results are compared with the H/V of a ground motion recorded in two stations. In general, results are in agreement and show that some areas display the phenomenon of amplification during a seismic action. The seismic vulnerability indices were also estimated, and values between 1 and 47 were obtained, indicating that the zones where the sediments overlie basaltic rocks are highly vulnerable, given the high impedance contrast. This microzonation study is a case study for the seismic risk assessment of Nador, ultimately contributing to urban planning and risk mitigation by defining suitable areas for building.
Article
During the 1st October 1995 Dinar, Turkey, earthquake, a total of 90 people died and about 240 people were injured. The number of collapsed or heavily damaged buildings exceeded 8000 within a radius of 20 km around the epicentre. The ground rupture was about 11 km long along an unexpected, new fault line. The reinforced concrete moment resisting framed structures as well as brick masonry houses experienced the most severe damage, especially those situated on soft soil layers of alluvium formations.
1: Map of the affected area -Kobe and vicinity
  • Fig
Fig. 1: Map of the affected area -Kobe and vicinity. (P: Port Island, R: Rokko Island).
Urban Japan - Image and Reality
  • A E G Morris
  • Morris A. E. G.
Preliminary Reconnaissance Report of the 1995 Earthquake
  • M Nakashima
  • M Bruneau
  • Nakashima M.