Song Hee Kim

Song Hee Kim
Asan Medical Center | AMC · Asan Institute of Life Sciences

About

25
Publications
1,481
Reads
How we measure 'reads'
A 'read' is counted each time someone views a publication summary (such as the title, abstract, and list of authors), clicks on a figure, or views or downloads the full-text. Learn more
55
Citations
Introduction

Publications

Publications (25)
Article
Full-text available
To evaluate the safety and efficacy of combining EW-7197 with irreversible electroporation (IRE) for improving wound healing, 16 male Sprague–Dawley rats were randomly divided into four groups of four rats each after dorsal excisional wound induction: sham control group; oral administration of EW-7197 for 7 days group; one-time application of IRE g...
Article
Full-text available
Irreversible electroporation (IRE) is a non-thermal ablation technique for local tumor treatment known to be influenced by pulse duration and voltage settings, affecting its efficacy. This study aims to investigate the effects of bipolar IRE with different pulse durations in a prostate cancer mouse model. The therapeutic effectiveness was assessed...
Article
Full-text available
Eustachian tube balloon dilatation (ETBD) has shown promising results in the treatment of ET dysfunction (ETD); however, recurrent symptoms after ETBD frequently occur in patients with refractory ETD. The excessive pressure of balloon catheter during ETBD may induce the tissue hyperplasia and fibrotic changes around the injured mucosa. Sirolimus (S...
Article
Full-text available
Background: In-stent restenosis caused by tissue hyperplasia and tumor growth through the wire meshes of an implanted self-expandable metallic stent (SEMS) remains an unresolved obstacle. This study aimed to investigate the safety and efficacy of SEMS-mediated radiofrequency ablation (RFA) for treating stent-induced tissue hyperplasia in a rat gast...
Article
The application of irreversible electroporation (IRE) to endoluminal organs is being investigated; however, the current preclinical evidence and optimized electrodes are insufficient for clinical translation. Here, a novel self-expandable electrode (SE) made of chemically polished nickel-titanium (Ni-Ti) alloy wire for endoluminal IRE is developed...
Article
Full-text available
This study aimed to investigate the efficacy of a closed-cell self-expandable metallic stent (SEMS) with or without expanded-polytetrafluoroethylene (e-PTFE)-covering membrane in a porcine iliac artery model. Twelve Yorkshire domestic pigs were divided into a bare closed-cell SEMS (B-SEMS) group (n = 6) and covered closed-cell SEMS (C-SEMS) group (...
Article
Clostridium novyi-NT (C. novyi-NT) is an anaerobic bacterium that can be used for targeted cancer therapy because it germinates selectively in the hypoxic regions of tumor tissues. However, systemic administration of C. novyi-NT spores cannot effectively treat tumors because of the limited intratumoral delivery of active spores. In this study, we d...
Article
Full-text available
Absorbable magnesium (Mg) stents have an attractive biocompatibility and rapid degradation rate, but their degradable behavior and efficacy in the Eustachian tube (ET) have not yet been investigated. In this study, the degradable behavior of the Mg stent in artificial nasal mucus was evaluated. The Mg stents in the porcine ET model were also invest...
Article
Full-text available
As a non-thermal ablation method, irreversible electroporation (IRE) has been widely investigated in the treatment of prostate cancer. However, no consensus has been achieved on the optimal parameters of IRE for prostate cancer. Since high voltage is known to carry risks of muscle contraction and patient discomfort, it is crucial to identify the mi...
Article
Background: The relatively low aqueous solubility of EW-7197 that was administered orally may have affected the desired concentration in the systemic circulation for treating peritoneal adhesion. This experimental study aimed to compare the efficacy of different routes of administering EW-7197 (2-fluoro-N-[(5-[6-methylpyridin-2-yl]-4-[(1,2,4)triaz...
Article
Full-text available
Several investigations on the feasibility of stent placement into the Eustachian tube (ET) are being conducted. However, stents optimized for the anatomical structure of the ET have not yet been developed. In this study, the efficacy and safety of a self-expandable metallic stent (SEMS) optimized for porcine ET morphology was investigated. Silicone...
Article
Full-text available
Background: Irreversible electroporation (IRE) has been investigated in the alimentary tract; however, the lack of dedicated electrodes and insufficient tissue responses made its application limited. The aim of this study was to investigate the efficacy and safety of image-guided stent-directed IRE in the rat esophagus. Methods: The bipolar self-ex...
Article
Full-text available
Endoluminal radiofrequency (RF) ablation has been widely used as a safe and effective treatment for Barrett’s esophagus. However, inadequate RF ablation may occur due to insufficient contact between the electrode and target tissues. Herein, a stent-based monopolar RF electrode (SE) was developed to evenly deliver RF energy to the inner wall of the...
Article
Full-text available
Conventional irreversible electroporation (IRE) with low-frequency pulsed electric field (LF-PEF) is used to induce cell death; however, it has several disadvantages including a long procedure time and severe muscle contraction due to high-voltage electric field. This study investigates a novel IRE protocol with high-frequency pulsed electric field...
Article
Full-text available
Stent-grafts composed of expanded polytetrafluoroethylene (e-PTFE), polyethylene terephthalate (PET) and polyurethane (PU) are characterized by poor endothelialization, high modulus, and low compliance, leading to thrombosis and intimal hyperplasia. A composite synthetic/natural matrix is considered a promising alternative to conventional synthetic...
Article
Full-text available
Various preclinical studies with developed Eustachian tube (ET) stents are in progress but have not yet been clinically applied. ET stent is limited by stent-induced tissue hyperplasia in preclinical studies. The effectiveness of sirolimus-eluting cobalt–chrome alloy stent (SES) in suppressing stent-induced tissue hyperplasia after stent placement...
Article
Full-text available
Intraductal radiofrequency (RF) ablation combined with placement of a self-expandable metal stent (SEMS) for malignant biliary obstruction has risks such as stent- and heat-induced biliary sludge and restenosis. Here, we investigated the efficacy of a silver nanoparticles (AgNPs)-coated SEMS to inhibit tissue hyperplasia and bacterial growth caused...
Article
Full-text available
Newly developed transrenal ureteral occlusion self-expanding metallic stents (SEMSs) are applied in patients with inoperable fistulas. In this study, the occlusive properties of M- and D-type occlusion SEMSs were investigated in 3D-printed phantom and ex vivo porcine urinary tracts. In the former, the mean bursting pressure causing leakage of contr...
Article
Full-text available
This study investigated whether interwoven self-expandable metallic stent (I-SEMS) placement suppresses stent-induced tissue hyperplasia compared with conventional knitted self-expandable metallic stent (K-SEMS) placement in a rat esophageal model. Twelve rats were randomly assigned to the I-SEMS (n = 6) and K-SEMS (n = 6) groups. All rats were sac...
Article
Full-text available
The exposure of the prostate to high electric field strength during irreversible electroporation (IRE) has been extensively investigated. Multiple monopolar electrodes, however, have risks of organ piercing and bleeding when placing electrodes. A novel bipolar electrode made of pure platinum and stainless steel was developed for prostate cancer abl...
Article
Full-text available
Stent migration is a significant obstacle to successful stent placement. There has been no investigation of the effect and quantitative interpretation of flaps attached to a plastic stent (PS) on antimigration. The antimigration effects of the number of flaps on a PS in a 3D-printed pancreatic phantom (3DP) and extracted porcine pancreas (EPP) were...

Network