The quest for a sustainable built environment has resulted in dramatic changes in the process of residential construction. The new concepts of an integrated design team, building information modeling, commissioning of the building enclosure, and passive house standards have reached maturity. Global work on development of new construction materials has not changed, but their evaluation is not the same as in the past when each material was considered on its own merits. Today, we look at the performance of a building as a system and on the material as a contributor to this system. The series of white papers—a research overview in building physics undertaken in European and North American researchers—is to provide understanding of the process of design and construction for sustainable built environment that involves harmony between different aspects of the environment, society, and economy. Yet, the building physics is changing. It merges with building science in the quest of predicting building performance, it merges concepts of passive houses with solar engineering and integrates building shell with mechanical services, but is still missing an overall vision. Physics does not tell us how to integrate people with their environment. The authors propose a new term buildings with environmental quality management because the vision of the building design must be re-directed toward people. In doing so, the building physics will automatically include durability of the shell, energy efficiency, and carbon emission and aspects such as individual ventilation and indoor climate control. This article, which is part 1 of a series, deals with materials, and other issues will be discussed in following papers.
Content may be subject to copyright.
Article prepared to press
Buildings with environmental quality management,
Part 1: Designing multifunctional construction materials
Mark Bomberg1, Marcin Furtak2 and David Yarbrough3
Abstract
The quest for a sustainable built environment has resulted in dramatic changes in the
process of residential construction. The new concept of an integrated design team,
building information modeling, commissioning of the building enclosure, and passive
house standards have reached maturity. Global work on development of new construction
materials has not changed, but their evaluation is not the same as in the past when each
material was considered on its own merits. Today, we look at the performance of a
building as a system and on the material as a contributor to this system. The series of
white papersa research overview in building physics undertaken in European and North
American researchersis to provide understanding of the process of design and
construction for sustainable built environment that involves harmony between different
aspects of the environment, society, and economy. Yet, the physics is changing. It merges
with building science in the quest of predicting building performance, it merges concepts of
passive houses with solar engineering and integrates building shell with mechanical
services, but is still missing an overall vision. Physics does not tell us how to integrate
people with their environment. The authors propose a new term buildings with envi -
ronmental quality management because the vision of the building design must be re -
directed toward people. In doing so, the physics will automatically include durability of the
shell, energy efficiency, and carbon emission and aspects such as individual ventila tion
and indoor climate control. This article, which is part 1 of a series, deals with mate rials,
and other issues, will be discussed in following papers.
KEYWORDS: Sustainable built environment, construction materials, building science, building
physics, material evaluation, integrated testing and modeling
1
Adj. prof. dr.,McMaster U, Hamilton, ON, Canada, honorary mem. BETEC/NIBS, Washington DC, USA
2
Prof. dr. arch. Director of Lesser Poland Energy Efficiency laboratory (MLBE), TU Cracow, Poland
3
Emeritus Prof. dr. Tennessee Tech. University, V. President R&D Services, Inc, Cookeville, TN, USA
Corresponding author: mark bomberg, e-m mark.bomberg@gmail.com
2
Introduction
A traditional title given upon completing an advanced academic work is doctor of
philosophy. This article comes as an address from two philosophers, called teachers
of building science (physics) and an architect who came to this field by different
route, but who share the need to define the final goal before starting the work.
Speaking about application of building science, we need to start with defining
some basic concepts. Leonard Bachman, in the course of Architecture at Houston
University 2013, used the following definitions: (1) Data = characteristics or prop-
erties measured on materials or systems; (2) information = an effect of the process
of transforming data into clusters on which decision process can be based; (3)
knowledge = information that is in conformance with other fields of organized data;
and (4) understanding = ability to reproduce knowledge from first principles and
apply it to the unique situations.
Using these definitions, we agree that the ultimate objective of building science
is to provide understanding of the process of design and construction for a sustain-
able built environment involves harmony between different aspects of the environ-
ment, society, and economy. A definition of sustainability involves different scales:
country, region, city, or individual building. The term balanced buildings means a
building where each of the above aspects is equally important, clarifies an under-
standing of the concept of sustainability. As we judge our research work from this
perceptive, we may as well call the following reviewa philosophical discussion.
This article is the first in series of research overview papers that extrapolate from
40 years of experience in passive housing. Yet, the use of solar energy in traditional
passive house design is limited to the level to which the ventilation (natural or
mechanical) can eliminate the summer overheating. To increase the solar energy
contribution, we will use water-based heat pumps for surface heating or cooling and
by hydronic means that controls the contribution of thermal mass to the energy
balance. Furthermore, we will use moisture buffering materials to modulate indoor
relative humidity. Effectively, the first lesson from the last 40 years that is presented
in this article is that all materials used in modern house must be multifunctional and
their selection is based on how well they satisfy requirements of the walls, floor, and
roofs.
North American chaos in residential construction 19461990
North American buildings are conceived with a bias toward the heating season
because heating is perceived to be more expensive than cooling. Energy conserva-
tion became a keyword after the crisis in the mid-1970s but has recently achieved
Bomberg et al. 3
national recognition. Statistical data, however, reveal that typical yearly energy use
in multiple residential buildings (MURB) in 1990 in Vancouver, Canada, was 315
kWh/m2. Since 1990, energy use in those buildings steadily declined, reaching 250
kWh/m2 per year in 2002 (Finch et al., 2010). This would be fine, until we find that
the energy use rates of 2002 are identical to those of MURB built in 1929. In other
words, the uninsulated masonry buildings in the 1920s and the shiny, glass-clad
buildings of today uses the same amount of energy, despite all of the energy-saving
measures currently available. Is this because of the new facade standards and
aesthetic values are expected?
This is not a surprise to a scientist. Centuries of small improvements resulted
in massive structures responding slowly to the exterior climate. In temperate
climates, these buildings were relatively comfortable by employing simple
provisions such as high ceilings, fans, and cross ventilation. In cold climates,
heavy masonry stoves in the middle of a dwelling or radiators that worked a few
hours a day provided heating, but the thermal mass of the building served as a
“heat battery” releasing energy without using fuel, and, of course in proportion
with decreasing indoor temperature.
These buildings were airtight because both sides of exterior walls were covered
with lime-based plasters. Lime develops strength slowly, allowing settlement of
walls while maintaining adhesion and continuity and thanks to its elasticity it resists
macro-cracking and has a self-healing capability. Double-hung windows
(casements in Europe) were well integrated into the masonry and repainted every
few years with oil paint. Thermal controls were simple, with devices such as radia-
tors controlled by a manual valve and a supply of steam or hot water from boilers
resulted in indoor temperatures that varied between periods of comfort and dis-
comfort as the exterior conditions changed. The number of openings was reduced
mostly to those following the building’s function.
The unbalanced progress in North American construction
Discussion of progress requires defining the frame of reference. What clearly
would be a progress in house building industry we call retreat from the balanced
buildings perspective because economic progress was achieved without resource
optimization and without environmental considerations. No one has studied the
impact of changing aesthetic tendencies on these values.
In 1900, there were about 500 different construction products to choose from in
the Swedish market. By 1950, the number increased to about 5000 and today we
can find 55,000 to 60,000 different products.1 Growth of specialized expertise and
the fragmentation of the design process erased the capability of an architect to
control the design process. The economic effect and the need for innovative and
attractive forms that were selling the buildings took over the design process.
In Europe, moisture was not a serious consideration because masonry is resilient
to moisture and bricks exposed to freezethaw conditions were carefully selected.
The accumulation of water has been a major problem for wood frame
buildings of North America. Bomberg et al. (2015) identified 12 papers and
books printed between 1938 and 1958 that dealt with water vapor transfer and
condensation. Yet, a lucid explanation of condensation, given in 1958 finally
got the attention of code and standards bodies. Why? at this time water
damage became evident in many buildings.
Condensation analysis was able to establish the occurrence of condensation, but it
did not predict the amount of condensate because it dealt only with one aspect of water
vapor transport and liquid (condensed) water moves by osmotic, capillary, or
gravitational forces. Bomberg et al. (2015) discussed this issue in detail to highlight
that typical construction practices did not use the building physics knowledge.
In the meantime, the architect’s fascination with large windows forced engineers
to increase the level of thermal insulation until one found that light-weight buildings
with large amounts of glass in the walls were leaky and had a multitude of
microclimates within one building. Thermostats covering large zones could not
provide adequate control. Heating slowly evolved to forced-air heating, ventilation,
air-conditioning (HVAC) systems. HVAC systems could provide summertime
cooling and dehumidification, as well as wintertime heating and humidification.
Thermostatic controls for these systems operated with tight set points. In short,
mechanical systems took over 100% of the task of climate control.
Air quality and moisture concerns in North America
The simplified version of building physics that was used by many national codes led
to stringent requirements for water vapor barriers (retarders). In Canada, for example,
vapor barriers were required to have permeance of less than 0.75 perm [45 ng/(Pa m2
s)] when measured on aged products. The emphasis on water vapor control received
a disproportionate amount of attention just because it is easy to calculate. Some
“authorities having jurisdiction” went as far as stating that no condensation was
allowed.
The change of directions was brought about by construction practice. To replace
traditional heating systems with electric baseboard heating, builders increased again
the levels of thermal insulation in the cold regions of Canada. These electrically
heated buildings, unfortunately, showed condensate on second-floor windows
(Bomberg et al., 2015). These observations led to new recommendations for air-
tightness of the ceiling construction and new partition-to-ceiling details. The linkage
between electrically heated houses and patterns of natural ventilation was now
evident.
In a parallel development, air exchange rate in houses with flue-less combustion
furnaces was found to fall below that required by codes, implying that well-insulated
houses with substantial airtightness may not provide sufficient air exchange when
built without chimneys. The 1980 Canadian National Building Code required that all
dwellings have a ventilation system capable of providing 0.5 air changes per hour
(ach)
Bomberg et al. 5
In 1990, based on the observations that these ventilation rates resulted in too-dry
air in winter, this requirement was reduced to 0.3 ach. Now the focus on indoor air
quality (IAQ) and moisture management moved from natural ventilation and vapor
barriers to mechanical ventilation and air barriers. Incidentally, air, water
(weather), and vapor barriers products gave rise to new industries.
From the building physics viewpoint, a light-weight, fully air-conditioned build-
ing eliminated all the advantages that had existed with the old masonry buildings.
To use thermal mass, one should use variable interior temperatures. Without the
contribution of thermal mass, the HVAC system must deal with peak heating and
cooling loads and the size of the system must be increased. Furthermore, zones in
large buildings were based on the assumption that interior air is static, whereas in
thermal stratification, multi-zonal air flows, and even the occupant activity, all of
these factors worked against the satisfactory operation of systems where ventilation
was combined with air-conditioning.
Finally, as the traditional HVAC systems operate on dry air temperature and
achieving comfort during cooling involves both latent and sensible loads, the whole
field of air dehumidification had to be created for the southern part of America.
Transition to low-energy housing (19902020)
It is difficult to find a precise time when codes and standards across the world started
a race toward near zero or net zero energy structures. Canada, in the late 1980s,
created integrated design process (IDP) teams mostly because we had no one with
experience on how to deal with design of so-called sustainable buildings. Yet, design
cost increases more when changes to the design are introduced later in the process so
moving most decisions at the front of the process proved beneficial to all parties.
The integrated, performance-based design differs from the conventional way of
design, where a building was “engineered in pieces” to objectives defined by
experts working individually in the process of design. An integrated design process
is the modern way to realize “performance architecture” that is, design with a view
to field performance. In this process, however, all members of the design team must
have some knowledge of building science.
This knowledge of building science allows them to translate the user requirements
into the measurable performance objectives that will eventually define the design
process (Table 1).
Table 1. Performance requirements as defined by Hutcheon (1953).
Control heat flow
Con trol a ir flo w
Con trol water vapor flow
Con trol rain flow
Con trol groun d water flow
6
Control light and solar radiation
Control noise and vibration
Control pollutants, odor, and vermin
Con trol f ire
Provide strength and rigidity
Be durable, resilient,a aesthetically pleasing and economical
_________________________________________
a Resilient is added to consider flooding, hurricanes and similar events
While architects continue to have an integrating role within these teams, it is
especially important for architects to understand building physics and communicate
with other experts in the design team. We have observed, however, that many
universities do not teach the principles of design and interaction between different
subsystems but treat building physics as another academic topic where equations
replace the process of functional analysis and logic of integration of different
subsystems. For this reason, we keep in North America the term building science that
was defined by late professor N.B. Hutcheon.
The imperatives of near zero energy buildings seek to address comprehensive
environmental control (thermal, moisture, and air infiltration) as formative and
integrated issue in the process of design. Such a design includes the following:
Energy efficiency of the envelope, with understanding of interactions
between thermal, moisture, and air flows;
Durability of materials and assemblies that have been evaluated for long-
term thermal and moisture performance aspects and includes the cost of
operation and maintenance;
Indoor environment (IE) that includes a comprehensive approach to envi-
ronmental control addressing all parameters of thermal comfort and air
quality.
In the past, environmental control involved only mechanical engineers. Today,
large, advanced buildings use ventilation interacting with heating, cooling, humidity
control, and even air purification. These strategies, however, should be scaled and
applied for any size of buildings. All of the people in a design team must understand
how combined action of HVAC and building enclosure shapes the IE. By
identification of competence, we have defined a core of the design team: (1) civil
engineer, (2) mechanical engineer, (3) building scientist capable of hygrothermal and
energy modeling, (4) construction cost estimator, and (5) an architect as a formal
leader together represent a core of the integrated design team.
What are we missing in this transition?
Energy modeling has been preoccupied with mechanical systems for heating, cool-
ing, and ventilation while neglecting their interaction with building enclosures. To
produce correct results, hygrothermal models must be added to the modeling effort.
Bomberg et al. 7
These models, however, must deal with real-time solutions and not only with
comparative simulations. We need to improve current hygrothermal models that
were originally developed for parametric study so that they may be used for real-
time modeling of the interacting transport phenomena. The improved hygrothermal
models must include information on air leakage through the walls and estimate the
impact of air and moisture transport on energy.
Moisture buffering can not only modulate indoor relative humidity but also
reduce peak energy loads. Uncontrolled relative humidity affects both IAQ and
durability of building materials. Expansion of hygrothermal modeling capability is
necessary because hygrothermal insulation instead of thermal insulation offers sig-
nificant economic advantages and could allow the development of walls to act as
heat and moisture exchangers.
It is time that building physics become re-focused on development of computer-
ized tools for predicting field performance of integrated environmental control sys-
tems. Better computer modeling is necessary to fine-tune the desired outcomes of
these systems and without these tools the performance of new systems cannot be
well understood and evaluated. Thus, building physics must create new tools to
reach an active and leading role in the movement toward net zero and near-net zero
energy buildings (NZEB).
For NZEB, multifunctional materials are a must
From a building science viewpoint, we have spent 5000 years in monolithic struc-
tures, the last 100 years in multilayered structures. Now, we are trying to reduce the
number of layers in the wall. To do it, we obviously need to use multifunctional
materials. While we talk multifunctional materials, we must also realize that criteria
for these functions are not defined on the material level but on the assembly level.
Building assembly is the lowest level in the building hierarchy in functional analysis
to which one can carry analysis down from the building level.
Observe that there is difference between science and many building codes where
requirements are ascribed to a specific material instead of an assembly. In some
cases, it works reasonably well while in others it is a miserable failure. For
instance, U values or thermal transmission in masonry buildings being ascribed to
the continuous insulation layer is close to an acceptable solution, but the same for a
steel frame building is not possible as it depends on where this insulation is located
and how environmental effects affect field performance. Even worse is the situation
about airtightness where permissible level of material airtightness is one magnitude
lower than that of an assembly and two magnitudes (100 times) lower than the
exterior wall of the building .
In reality, there is no conflict between building science and codes because codes
specify the minimum requirements and we should always design for requirements
higher than the minimum. Furthermore, codes deal only with the basic categories of
safety and health while the remaining categories are left for a qualified designer as
indicated in the above table.
8
For the sake of discussion, we consider four layers in any exterior wall, namely
(1) exterior facade, (2) exterior continuous insulation, (3) loadbearing (middle)
layer, and (4) interior trim and finish. It is clear that the facxade layer (1) must con-
trol fire, rain, air and water vapor entry, light, sound, radiation, and vermin; the
thermal insulation (2) controls heat, but may also control air, water, vapor, and
sound; the loadbearing layer (3) provides strength and rigidity but may also control
air, water, and vapor transports. Finally, the interior finish layer (4) should control
fire, air, water and vapor movements, and sound. Yet, the whole wall must be
durable, economical, and have control of ground water.
How are those layers actually working?
Facxade layer may be either directly attached and perform required functions
or be a rain screen enclosing an air gap behind (e.g. brick veneer) to provide
rain control. In this case, the next layer, on the other side of the air gap,
should be a thermal insulating composite with a surface that fulfills all of the
facxade requirements.
Thermal insulating composite must also control acoustics. This means that if
heavy concrete is not used for loadbearing, then the finishing surface on the
thermal insulation must contribute to the attenuation of structural vibration.
Today, however, popular solutions such as mineral fiber with wind protec-
tion or polystyrene boards with taped joints do not fulfill all requirements for
air, water vapor, and vermin entry.
The selection of the loadbearing layer depends on the height of the building
but for a low rise a light-weight concrete with metal mesh reinforcement that
is additionally protected from corrosion is a suitable solution.
The requirements for airtightness and fire resistance of interior finishes are
fulfilled by gypsum board that is water vapor permeable and have little
buffer capability
Effectively, one must remember that multifunctional materials are developed and
evaluated for a specific application and their use in different applications requires a
new evaluation.
An example of a multifunctional wall composite
Large windows exposed to the sun are recommended by many architects who fol-
low the wishes of the occupants. Glass connects occupants with the outer world
and is here to stay. So an engineer has to solve the technical problems instead of
trying to limit the size of windows. We have observed that windows expose occu-
pants to asymmetric heating and cooling surfaces and dynamic changes in air tem-
perature. To alleviate the discomfort issues, we need to re-examine two sets of
issues, namely:
(1) Dual function control for the water-to-water heat pump to address heating
and cooling required to control overheating.
(2) Re-circulation of ventilation air to equalize temperatures in sunny and
shaded areas.
Bomberg et al. 9
Figures 1 and 2 show that increasing thickness of thermal insulation to about
double of this that was introduced in 1970’s brought back the forgotten effects of
thermal bridges as their effect on temperature differences has also been doubled.
Figure 1. Infra-red camera sho ws all thermal anomal ies on exterior thermal insu lation
composite system with 14-cm-thick expanded polystyrene. Connectors and hot water lines are
shown as hot spots (HS) in contrast to corners and trees that are seen as cold spots (CS) .
Source: From Ad am Gryl ewicz (workshop at TU Cracow, 2015).
Figure 2. Facxade of a building at Cracow TU after thermal upgrade with ETICS having a thick layer of
thermal insulation. Drying on mechanical fasteners is faster that adjacent insulation that is still wet from
morning condensation. Source: Photo courtesy of Tomasz Kisilewicz.
Figure 3. Two fundamental requirements that are shown in a frame in the right, bottom corner impact the
process of integrated design of environmental control
The complex of factors interacting on IE is presented in Figure 3. It shows an
integrated heating, cooling, and ventilation system where a water-to-water heat
pump is supported by a solar thermal collector that heats and stores water. The
storage provides hot water through reinforced polyethylene (PEX) tubing to panels
located on the interior of the exterior wall. At the same time, a central air-supply
system, drawing geothermally pre-conditioned air, delivers it to each room. The
room (if it is exposed to solar radiation) is also provided with individual ventilation.
The framed area in Figure 3 (right, bottom corner) shows both the individual
ventilation and heating/cooling panel.
This solution addresses several different dimensions of IE, namely (1) IAQ, (2)
personal control of IAQ, (3) noise control, (4) individual ventilation, (5) thermal
comfort, (6) thermal, and (7) humidity buffers to reduce rapid changes in the IE.
These elements result in occupant satisfaction in the case of residences and
increased productivity in the case of work environments.
Figures 4 and 5 show the construction of a composite panel under discussion.
The structural support was made from 40-mm-thick extruded polystyrene board;
insulation board 1 was made from expanded polystyrene, while eco-wrap material
was limecementash mixed with rice fibers and hulls powder as well as other
industrial recycling materials. The heating/cooling pipe was 12mm in diameter.
Bomberg et al. 11
Figure 4. Multifunctional composite panel for interior of buildings (Hu, TU Nanjing, China
from the presentation at Workshop at TU Cracow, 2015
Figure 5. Multifunctional composite panel for interior rehabilitation of buildings (Hu, as above).
The reason for showing this example is twofold: (a) a demonstration of how
multifunctional materials and assembly form a seamless matrix of integrated design
and (b) to stress that during the integrated design one reviews all relevant experi-
ences in environmental control. Typical issues involve the following:
Fresh air delivery. Note that the medical profession determined the amount
of fresh air needed for people about 100 years ago (Baker, 1912), yet
there is no consensus on how to overlay these requirements with different
HVAC systems whose air-mixing efficiencies vary. 1
For a healthy ventilation system, all significant sources of pollutants should
be removed.
Bomberg et al. 12
Large central ducts and short high-velocity small-diameter ducts show good
acoustical and air-delivery performance (Wallburger et al., 2010).
Balanced ventilation systems that include supply and return ducts or central
supply with individual exhaust completing the supply have also a good
record of performance.
Partitions (interior walls) in buildings to satisfy airtightness and of fire codes
create a multitude of zones with individual climate controls. Water-based
radiant systems with smart controls have a good record of performance in
maintaining thermal comfort.
Water-to-water heat pumps used with hydronic heating systems can operate
at low temperature and be easily integrated with solar thermal panels.
Variable refrigerant flow (VRF) technology allows using different heating or
cooling rates as required in different rooms.
A dedicated central ventilation system is beneficial when dehumidification is
needed. With independent dehumidification and ventilation systems that
provide coupling to thermal mass, buildings can maintain comfort during
large periods of the summer simply by reducing humidity. This potentially
saves substantial amounts of energy.
Integration of testing and modeling on assembly level
In 1970s, when the theory of functional analysis was under international consider-
ation, a new category of performance tests was introduced. One example of such
test was an impact test that used a 50 kg mass sand bag on a 150cm string. Before
the test is started, the string is stretched horizontally. When released the gravity
forced the bag to go along a circle and hit the wall. This test obviously is better than
an impact test with a small and hard object but does it really represent a real hazard
of damage by impact?
We can call this a “performance-oriented” test because such a test is easier to
correlate with the damage mechanisms observed in the field performance. This may
be better understood when examining the stages in test development contained in
Table 2.
Looking at Table 2, one realizes that the vague objectives of performance-
oriented tests with unknown accuracy do not provide better linking the outcome of
the test to field conditions than it was a case with the standard rating test. Thus,
neither a rating test nor a performance-oriented test alone is sufficient for evaluating
field performance of a construction assembly. An assembly is a building element
such as a wall, door, window, or roof that consists of a combination of
materials and typically provides a separation between spaces. In many cases, one of
the spaces is the outdoors and if weather is a boundary condition describing it for
the purpose of modeling this requires a substantial set of skills.
Table 2. The process of test method development
Identify factors leading to the objective
Det ermine how to quantify these factors
Choice of measuring method and unit test method)
Write a test procedure
14
Determine precision and bias
Evaluating how the measurement meets an objective
Bomberg et al., (2016a), observed that almost all hygrothermal models used today
are simplified by neglecting capillary hysteresis despite the fact that such is
included in modeling used in soil science or in evaluation of stress/stain caused by
hygrothermal changes. Nevertheless, these models permit on evaluation of effects
such as material variability and changes in climate on the heat, air, and moisture
transmission through a building assembly.
Thus, like in other engineering disciplines, we must use a process of integrated
modeling and testing. This statement is self-evident because testing cannot address
the effects of variable weather conditions and modeling cannot address interaction
between structural and environmental stresses, strains, and probable deficiencies of
materials. Adamson et al. (1968) and later Bomberg and Allen (1996) have applied
the limit states
4
approach to energy efficiency and durability assessment. To
support modeling approach, Bomberg and Pazera (2010) extended the issues of
material characterization for input to hygro-thermal modeling and model
calibration.
5
We will continue this review in two blocks of issues:
Energy efficiency of the building;
Priorities in environmental control during design.
Energy efficiency of the building
Design of low-energy buildings by an integrated team brings a new demand for all
participants of multidisciplinary team. Understanding of how building functions is
necessary for solving conflicts arising between different requirements, for example,
continuity of function and separation of space.
To our knowledge, building physics is taught as individual subject and in most
cases with focus on specific technical solutions. This may be suitable for those who
major in the topic but for other engineers and architects the stress should be on
design principals and interaction of different subsystems.
To achieve this objective, we need to reform education process in civil, mechani-
cal, and architectural faculties by introduction of one subject that, for the sake of
identification, we call, “Principals of building science,” a course that should be
taught in parallel to low-energy building course.
Developing a vision for design of low-energy buildings
For many decades, we used reliance on air-conditioning to shape IE, neglecting
experience from time when buildings responded slowly to the change in exterior
4
Limit states methodology was introduced to structural dimensioning about 100 years
ago and in 1960s to building physics by a book in Swedish (Adamson, Bergstrom, and
Nevander) describing needs for Scandinavian research program.
climate and used interior thermal mass as a “heat battery.” To use controlled
thermal mass of the building interior and to restore the balance between
requirements for building enclosure and mechanical devices becomes a key to
sustainable design.
To this end, we propose a term Building with Environmental Quality
Management (EQM). The process of design and optimization includes three
stages:
Using all possible passive measures in design of the house even though the
only two of the many existing passive house criteria are required. In this
process, new multifunctional materials and integrated HVAC with building
enclosures are introduced;
Using low exergy geothermal and solar thermal measures to interact and to
extend passive measures;
Using photovoltaics or other renewable measures to the extend economics
allows.
Developing a real-time hygrothermal models
We use the building component (assembly) level as the basis of evaluation. The
multitude of possible paths prevents us from going down to the material level. To
link materials with subsystems while simultaneously addressing the effect of mate-
rial variability and climate, we need to upgrade our modeling capability. One often
talks about modeling system to highlight the need for linking of these models.
Whether these models are linked with Energy plus or IDA-ICE, the hygrother-
mal part of the system must be:
(1) 2D or 3D real-time calculation code, that is, include capillary hysteresis
and continuity of momentum on the material boundaries;
(2) Have one set of output data allowing it to be considered as input to the next
calculation;
(3) Dynamically linked with whole building energy calculation;
Include verification of material and assembly characteristics.
Developing wall assembly characterization
Despite the fact that laboratory and field testing use the same scale and identical
construction, there is no equivalency between laboratory and field performance
test on assemblies. This is caused by the difference in the boundary conditions and
connectivity of the building assembly with adjacent assemblies. Air is entering to
the walls and floors in places much different than it is leaving the building. For
instance, air may enter through electrical or plumbing penetrations but exit at wall
window interface. Results of the airtightness testing provide examples of missing
equivalency between laboratory testing and the difference is often as large as one
magnitude. Furthermore, field airtightness is often weather dependent.
15
To address the effect of weather, we must use hygrothermal models but these
models must be calibrated for the actual materials and wall assemblies.
Methodology of hygrothermal models verification and calibration on the material
level was discussed elsewhere (Bomberg and Pazera, 2010). Yet, there are no pub-
licly available methods of characterization of air flow through a wall assembly.
Such development is necessary if we want to use hygrothermal models for the real-
time calculations.
Experience indicates that such a method should be based on a combination of a
tracer gas and blower door technology to characterize degree of connectivity of a wall
assembly with interior and exterior air (Thorsell and Bomberg, 2011).
Closing remarks
A “White Paper’s” (research overview) role is to highlight week points in the emer-
ging knowledge and the process often starts with the vision. It may be stated that
over last 40 years we have produced enormous volume of new technology but with-
out the leading focus, this progress may not be efficiently used. We propose a new
label for our activity so that the vision of EQM would allow seamless connection
between HVAC and building enclosure as both of them shape IE. EQM includes
passive house design and low exergy measures; it does not change anything but
requires quantification of all effects of these measures that we undertake to manage
the indoor environment.
Declaration of conflicting interests
The author(s) declared no potential conflicts of interest with respect to the research, author-
ship, and/or publication of this article
Funding
The author(s) received no financial support for the research, authorship, and/or publication
of this article
.
References
Adamson B, Bergstrom S and Nevander LE (1968) Moisture as Problem in Building
Technology (in Swedish).
Baker AH (1912) The Theory and Practice of Heating and Ventilation. London: The Carton
Press, 1912.
Bomberg M and Allen D (1996) Use of generalized limit state method for design of
building envelope for durability. Journal of Building Physics 20(1): 1839.
Bomberg M and Pazera M (2010) Use of hygrothermal models for real time performance
analysis: methods to check reliability material characteristics. In: Proceedings of the
central European symposium on building physics, TU Cracow, Cracow, paper no. 128.
\Bomberg M, Gibson M and Jian Z (2015) A concept of integrated environmental approach
for building upgrades and new construction: part 1setting the stage. Journal of Building
Physics 38(4): 360385.
Bomberg M, Wojcik R and Piotrowski Z (2016a) A concept of integrated environmental
approach, part 2: integrated approach to rehabilitation. Journal of Building Physics
39(6):482502.
Bomberg M, Kisilewicz T and Mattock Ch (2016b) Methods of Building Physics in Design of
Zero Energy Ready Buildings. Cracow University Press, 1310.
Finch G, Burnett E and Knowles W (2010) Energy consumption in mid and high rise
residential buildings in British Columbia. In: Proceedings of building enclosure science
and technology (BEST2) conference, BEST 2, session EE3 paper EE3-1. Available at:
http:// www.thebestconference.org
Hutcheon NB (1953) Fundamental consideration in the design of exterior walls for buildings.
NRC paper no. 3087, DBR no. 37. Ottawa, ON, Canada: Division of Building Research,
National Research Council of Canada.
Thorsell T and Bomberg M (2011) Integrated methodology for evaluation of energy
performance of the building enclosures. Part 3: uncertainty in thermal measurements.
Journal of Building Physics 35: 8396.
Wallburger AT, Bomberg M and Henderson H (2010) Energy prediction and monitoring in
a high performance Syracuse house. Available at http://thebestconference.org
... The concept of net zero revolves around achieving an equivalency between produced greenhouse gases and the removal of the amount of them. In the context of buildings, a NZEB is defined by its ability to maintain a near equilibrium between the total energy zero emissions in operation are easily achieved, embodied emissions remain significant [30][31][32][33][34][35]. In regard to NZEBs, EU programs like Horizon 2020 support NZEB design and its evolution into the PEB model. ...
... A critical review of EU actions on NZEB and PEB development, considering advanced materials and technologies, was presented in the mentioned research [31]. A case study of a single-family residential NZEB demonstrates that a carefully designed building envelope and systems can achieve almost total energy consumption coverage from renewables, generating a potential energy surplus for sharing with urban grids [32][33][34][35][36][37][38]. In another paper, the focus was on NZEB targets with high indoor air quality in an Italian multi-family complex converted from an industrial shed. ...
Article
Full-text available
Designing a nearly zero energy building (NZEB) and more exclusively a positive energy building (PEB) hold significant importance these days. Achieving this objective requires an effective blend of renewable systems and the energy efficient envelope. This study focuses on a villa situated in the southeast of Kerman, Iran with hot and dry summers. Commencing with the current energy-efficient design of the structure, the research conducted various analyses to explore the impacts of different strategies or alternative approaches that contribute to achieving a NZEB or PEB. The parameters examined in the analysis that pertain to the building envelope, encompass insulation scenarios, window-to-wall ratio, and glass types as passive strategies, along with the integration of wind turbine energy production as an active energy solution. The findings indicate that, under hot and dry conditions in this region, the optimal passive strategies for the case study involve a 40 % window-to-wall ratio, polyurethane insulation, and triple-layered glass with argon. This combination results in a noteworthy reduction in total annual energy consumption, decreasing from 24,344.56 kWh to 11,909.64 kWh. To offset the remaining energy requirements and transform the building into a positive energy structure, a wind turbine was employed. This integrated approach not only aligns with the specific climatic conditions of the area but also demonstrates the feasibility of achieving a positive energy building which resulted in a surplus energy of 1,414.13 kWh.
... Multifunctionality is a concept often used in the context of ecosystems, their performance and services (Manning et al., 2018). However, we propose expanding the concept to also encompass the artefacts and practices produced by societies such as materials, technologies, structures and cultures (Bomberg et al., 2017;Jerome et al., 2019). Such understanding highlights the dialectic of nature and society (Fuchs, 2006;Marx & Engels, 1975) and connects structure and function in a delimited geographical space (Belmeziti et al., 2018). ...
Article
Full-text available
The framing of nature as separate from culture impacts our notion of landscapes and the functions, infrastructures and activities deemed appropriate within these, where natural landscapes are associated with nature conservation, and the built environment with human activity. In this paper, we propose bridging this nature-society dichotomy through a multifunctional perspective as a way to adopt a more systemic view of space in relation to landscape traits as well as material artefacts. We argue that multifunctionality is not only fundamental for adaptation, but a way to reconcile questions of social equity with biodiversity and environmental goals. We build on global experiences with nature-based solutions to identify three major roadblocks hindering current adaptation approaches and outline four leverage realms for moving towards multifunctionality.
... Over many years, the two international standards, ASTM E96m and ISO 12572, have prescribed a single temperature of 23 • C (±1 • C) and a relative humidity 50% (±5%) for conducting the gravimetric water vapour transmission laboratory testing for construction materials [5,6]. Although these standards have been regularly revised over time, the reality and the demand for modern, healthy and energy efficient homes within our world's very diverse climates is causing a paradigm shift about the understanding of high-performance building envelope systems' hygrothermal analysis [7][8][9]. The problems associated with high indoor humidity, condensation, and mould growth currently prevalent in Australia buildings' cold and humid climate is common in many developing and developed nations, and high-quality material vapour diffusion data is needed to undertake hygrothermal simulations to inform regulatory development [9][10][11]. ...
Article
Full-text available
Hygrothermal modelling is increasingly used to inform building envelope design. A key input for these calculations is the material’s vapour diffusion properties. Respecting a growing international concern, this research has questioned the appropriateness of the current test method to establish construction material for vapour diffusion properties. This article reports on the empirical measurement of the vapour diffusion properties of two vapour-permeable building membranes commonly used in Australia residential systems when subjected to variable relative humidity conditions. The method involved completing dry cup and wet cup standard tests as specified in ISO 12572, (23 °C and 50% relative humidity RH). Further tests were then conducted as temperature remained at 23 °C but the relative humidity changed to 35%, 65% and 80%, respectively, in order to know if the diffusion properties are the same or change with varying relative humidity. The results from the wet cup and dry cup tests under different relative humidity conditions were non-linear and different. These results indicate vapour-permeable membranes behave differently when exposed to different relative humidity conditions. In conclusion, this research demonstrates that the current vapour resistivity test method is inadequate, hence the need to establish more detailed diffusion resistivity properties in different humidity ranges that represent conditions experienced within a building’s external envelope.
... This initiative of collaborating Chinese and European Universities (in which individual North American experts also participate) is therefore to reinforce the bridge between science and industry with focus on development of the next generation of affordable, environment friendly building technology. [11][12][13] ...
... With growing requirements on indoor air quality dehumidification and dust removal, the selection of air from different air intake sources (EAHX or direct outdoor supply) with an advanced control system becomes a part of the building design [22,23]. This paper provides a basic understanding of factors affecting the field performance of EAHX and gives some examples of practical solutions that can be used in the future design of preheating for air ventilation. ...
Article
Full-text available
The growing popularity of buildings with integrated sub-systems requires a review of methods to optimize the preheating of ventilation air. An integrated system permits using geothermal heat storage parallel to the direct outdoor air intake with additional treatment in the mechanical room as a part of building an automatic control system. The earth–air heat exchanger (EAHX) has many advantages but also has many unanswered questions. Some of the drawbacks are: A possible entry of radon gas, high humidity in the shoulder seasons, and the need for two different air intake sources with a choice that depends on the actual weather conditions. In winter the EAHX may be used continuously to ensure thermal comfort, while in other seasons its operation must be automatically controlled. To generate missing information about EAHX technology we examined two nearly identical EAHX systems, one placed in the ground next to a building and the other under the basement slab. In another project, we reinforced the ground storage action by having a heat exchanger placed on the return pipes of the hydronic heating system. The information provided in this paper shows advantages of merging both these approaches, while the EAHX could be placed under the house or near the basement foundation that is using an exterior basement insulation.
... To restore the thermal mass contribution, we decided to integrate heating and cooling with the building structure and to use the adaptable climate approach for indoor spaces. This approach is discussed elsewhere [23]. Observe that system integration again increases the role of the modern building automatics. ...
Preprint
Full-text available
Growing popularity of smart and integrated buildings requires a review of methods to optimize the preheat of ventilation air. An integrated system permits using heat ex-changers located in the mechanical room or in the future even using an exterior wall as a heat exchanger. One may ask the question how does the earth-air heat exchanger (EAHX) technology fitts into this function. EAHX has many advantages but also has many unanswered questions. Some of the drawbacks are: a possible entry of radon gas, high humidity in the shoulder seasons as well as the need for two different air intake sources with a choice that depends on the actual weather conditions. While in winter, the EAHX may be used continuously to ensure thermal comfort, in other seasons, its operation must be automatically controlled. To generate the missing information about the EAHX technology we reviewed literature and examined two nearly identical EAHX systems, placed either in ground next to the building or under the basement slab. Effectively, the information provided in this paper, shows advantages of merging both these approaches while the EAHX shoud be placed under the house or near the basement foundation.
Conference Paper
Full-text available
Achieving sustainability in building materials is a difficult task. In this research, the aim is to identify intellectual roots and to find an organized outcome of the status and trends analyzing the sustainability of Construction materials used in Building envelopes of group housing buildings and the construction industry. To provide support for the research, the PRISMA methodology is used for the extraction of related literature to identify articles for bibliometric analysis. The R-tool is then used to process the data extracted from the database in a graphical mapping analysis, which is used to evaluate the systematic literature review on this research domain. Using data from the Web of Science and Scopus databases, 50 papers were chosen for analysis. The study then extracts the annual publication on the topic, the authors' contributions, the articles' citation counts and conclusions, the contributions of various countries, enduring publications, and keywords. This study only discusses the elements that are now acknowledged in the literature to assess the sustainability of building materials, which are generally regarded as sustainable materials in India and throughout the world (environment, economics, and society). This study will help researchers and policy-makers working on the development of sustainability assessment decision-making frameworks for the selection of materials used in buildings worldwide, by providing a clear understanding of the actual work being done in this field, the necessary research gaps, and recommendations for future work.
Article
Full-text available
In this paper series, we will examine the relation between the smart grid and the next generation of buildings. The new objective is now to design buildings so that the energy exchange takes place in time suitable for both sides. The building takes energy from the grid and give it back at different time because in the next generation of buildings they are equipped in advanced control system that controls energy storage for several hours and the new or retrofitted building can eliminate energy peaks and valleys for itself and assist the smart grid in equalization of the load. The control systems include monitoring and modeling of energy use and indoor environment to arrive to a weather-based prediction, Therefore, in part 1 of the paper series we address collecting, processing and analysis of the measurement data that can be done by the new modular statistical software alone or in conjunction with a dedicated neural network. We want to minimize energy use and maximize the thermal comfort of the occupants. Using the modular structure of the database, data transformation technologies and other existing tools, the modular statistical software (MSS) has been created to process large amounts of data as input to the decision-making algorithm. This is to enable buildings automated control (BAC) to take over the control of heating/cooling, ventilation, illumination and other performance aspects that relate to sustainability of built environment.
Article
Full-text available
The European energy policies introduced the Nearly Zero Energy Building (NZEB) objective (Directive 2010/31/EU and 2018/844/UE) to stimulate the energy transition of the construction sector. EU programs, specifically “Horizon 2020”, promote the NZEB design and also its evolution, namely the Positive Energy Building (PEB) model. Based on the most recent developments, a critical review of the main actions of the European Union towards the development of the NZEB and PEB design models has been conducted. Some considerations on advanced materials and technologies (PCM, VIP, smart glass, integrated photovoltaic systems) have also been added. Finally, a case study is presented (single-family residential NZEB) to show how a careful and integrated design of the building envelope and systems not only allows to obtain an almost total coverage of the energy consumption by renewable sources, but also to generate an energy surplus that could be shared with urban grids (PEB potential).
Article
Full-text available
This is an overview of a Key Note lecture; the quote for this lecture is from T.S. Eliot: “We must not cease from exploration and at the end of all our exploring will be to arrive, where we began, and, to know the place for the first time”. This quote highlights that the process of scientific development goes in circles, yet each of them goes above the previous circle, building up the ladder of knowledge. Closing one circle and opening the next may be either be a quiet, unnoticeable event or a roaring loud, scientific revolution. Building science (physics) was started about 100 years ago, but only now are we closing its second circle. Perhaps, because of building physics’ role in the fourth industrial revolution, this discipline itself is undergoing a scientific revolution The first industrial revolution was based on steam generated by burning coal, the second was based on petroleum, and the third on electricity and concentrated electricity production. The current one, i.e., the fourth, is based on distributed energy sources combined with information technology.
Conference Paper
Full-text available
To determine hygrothermal performance of building envelope under given climate and service conditions one needs to use advanced hygrothermal (HT, also called heat, air and moisture”, HAM) model. As input one must enter weather data and material characteristics . The question arises: How does one ensure that a set of material characteristics from a handbook is suitable for describing performance of a specific assembly? One can make a statistically valid number of measurements to reduce uncertainty in determination of transport coefficients but the structure of the material may differ from that measured for the handbook. To develop a solid basis for application of hygrothermal models we must use methods of verification material characteristics. This allows initial “guess” of material descriptors and using verification tests one may fine-tune the initially assumed material characteristics.
Conference Paper
Full-text available
Many residential buildings in British Columbia and other parts of North America have, or are, undergoing comprehensive rehabilitation largely to remedy moisture-related problems. For reasons primarily related to short-term cost, little or no attention has been directed at energy conservation strategies and/or, greenhouse-gas emissions. Nevertheless rehabilitation of the building enclosure does present a unique opportunity to examine and assess the actual energy-related performance of the in-service building, and to determine the energy impact of the building enclosure improvements. To understand the impacts of building enclosure rehabilitation on the energy consumption of mid to high rise residential buildings in the Lower Mainland and Victoria, a large government and industry sponsored research project is currently underway. The principal objectives of the study are to review and assess the actual energy consumption of in-service mid and high rise residential buildings, and the impacts of building enclosure rehabilitation related improvements on the overall energy consumption at these buildings. The results of the study will also be used to develop better building enclosure design strategies that take into account energy conservation, and help reduce greenhouse gas emissions in both new and rehabilitated buildings. This initial paper on the study presents baseline consumption data from 39 multi-unit residential buildings (MURBs) in the Lower Mainland and Victoria, BC. The data provides an understanding into the current level of energy consumption within mid to high rise residential buildings. The contribution of gas and electricity to overall energy consumption and, specifically, space heat and ventilation are discussed in detail. The disconnect between building energy consumption and billing to occupants for their share of total energy usage is highlighted.
Article
Full-text available
In the first part of this series, we discussed that the building structure, energy efficiency, indoor environmental quality, and moisture management all need to be considered simultaneously to ensure durability of materials and control cost of near-zero energy buildings. These factors must be addressed through contributions of the whole design team. It is also evident that building physics must take an active role in development of near-zero energy buildings. The need to ensure good indoor environment and durability of materials and limit the cost of buildings led to integrated design process that now is typical in Canada for design of low-energy buildings. Furthermore, interactions between energy efficiency, quality of indoor environment and moisture management led us to introduce a concept of “environmental control.” In the meantime, we made an unexpected observation—Vancouver dwellings in 2002 use the same amount of energy as 1920 uninsulated masonry buildings erected in the same location. We concluded that despite having advanced technology, our lack of vision prevents us from an effective use of this technology. With the quest for sustainable buildings, we should learn more from termites, who appear to master the art of hygrothermal control better than humans as they are capable of maintaining highly stable interior comfort zone without heating, ventilating, and air-conditioning equipment. Nevertheless, whatever progress is achieved in new low-energy buildings, it is lost when rehabilitating existing buildings because there an owner will typically do one step at a time. If the financial constraints do not allow for more, this first step should be an integrated action that includes a combination of insulation and heating systems.
Article
Full-text available
This article highlights the need for an active role for building physics in the development of near-zero energy buildings while analyzing an example of an integrated system for the upgrade of existing buildings. The science called either Building Physics in Europe or Building Science in North America has so far a passive role in explaining observed failures in construction practice. In its new role, it would be integrating modeling and testing to provide predictive capability, so much needed in the development of near-zero energy buildings. The authors attempt to create a compact package, applicable to different climates with small modifications of some hygrothermal properties of materials. This universal solution is based on a systems approach that is routine for building physics but in contrast to separately conceived sub-systems that are typical for the design of buildings today. One knows that the building structure, energy efficiency, indoor environmental quality, and moisture management all need to be considered to ensure durability of materials and control cost of near-zero energy buildings. These factors must be addressed through contributions of the whole design team. The same approach must be used for the retrofit of buildings. As this integrated design paradigm resulted from demands of sustainable built environment approach, building physics must drop its passive role and improve two critical domains of analysis: (i) linked, real-time hygrothermal and energy models capable of predicting the performance of existing buildings after renovation and (ii) basic methods of indoor environment and moisture management when the exterior of the building cannot be modified.
Article
Full-text available
Thermal performance of building enclosure is typically based on laboratory tests performed on dry materials without consideration of air and moisture movement through the assembly. To address the field performance of the assembly, however, one must combine measurements and hygrothermal modeling. Hygrothermal models are necessary to include effects of climate and in particular the effects of moisture movement on thermal performance. Full-scale testing is necessary to relate findings of the models to actual construction details. The first paper in this series (Bomberg and Thorsell, 2008) introduced a test program that starting with benchmarking of the R-value of the tested wall in standard conditions, examined the effects of air flow on its thermal performance. This test program does not use the average R-values of the wall as it is in the ASTM testing, but measures local thermal resistance in selected places and calculates the average R-values. The second paper in this series (Thorsell and Bomberg, 2008) applied this integrated testing and modeling approach to selected wood framed residential walls, identifying the magnitude of air flow effects on steady-state thermal resistance, as well as demonstrating that the thermal performance of the top of the wall differs from that at the bottom. It also showed a systematic and time dependent shift in thermal performance caused by moisture movement. In this, third paper in the series, we present measurements performed on metal frame walls that introduce additional sources of uncertainty in the experimental results. We end with a discussion on the need of improvements to testing procedures for evaluation of energy performance of building enclosures.
Article
Full-text available
This paper introduces a generalized limit states (GLS) method for evaluating long-term performance of building envelopes. The limit states method was originally developed for the design of structures to satisfy performance require ments for safety and serviceability. However, it may be generalized to address durabi lity of building envelopes. The approach used in this paper involves selecting a re quired period of service (design life) for the component of the building envelope, and then to evaluate the envelope for durability by applying the GLS method.
Methods of Building Physics in Design of Zero Energy Ready Buildings
  • M Bomberg
  • T Kisilewicz
  • Mattock Ch
Bomberg M, Kisilewicz T and Mattock Ch (2016b) Methods of Building Physics in Design of Zero Energy Ready Buildings. Cracow University Press, 1-310.
Moisture as Problem in Building Technology
  • B Adamson
  • S Bergstrom
  • L E Nevander
Adamson B, Bergstrom S and Nevander LE (1968) Moisture as Problem in Building Technology (in Swedish).
Energy prediction and monitoring in a high performance Syracuse house
  • A T Wallburger
  • M Bomberg
  • H Henderson
Wallburger AT, Bomberg M and Henderson H (2010) Energy prediction and monitoring in a high performance Syracuse house. Available at http://thebestconference.org