Conference Paper
The paper presents the comparison of the width of transmission overhead power lines area of influence from the standpoint of electromagnetic field and protection area according to the Energy Law. The comparison is conducted for typical configurations of 110 kV, 220 kV and 400 kV transmission overhead power lines. The width of the power lines area o...
Conference Paper
In recent decades, there has been a constant trend of increasing the unacceptability of high- voltage lines for the population in the corridor's environment. At the moment of an exceptional increase in the demand for electricity, and in such a situation, solutions are inevitably sought to increase the capacity of the existing lines. New solutions h...
Conference Paper
The paper analyzes the legislation in the area of protection of the general public from the non-ionizing radiation, i.e. electromagnetic field, currently in force in the Republic of Serbia. The emphasis of the paper is on the power frequency (50 Hz) electromagnetic field in the vicinity of the transmission system elements, such as overhead and cabl...
Conference Paper
In the case of a single-phase ground fault, in situations where there is a residential building near the overhead line tower, it is necessary to analyze the risk of low-voltage electrical installation insulation breakdown. During the ground fault, there is an increase in the ground potential in the vicinity of the overhead line tower and, consequen...
Conference Paper
Levels of electric and magnetic fields in the environment in the vicinity of double- circuit overhead power lines vary significantly depending on the selected phase arrangement. The permitted levels of electric and magnetic fields in the environment are determined by national regulations in the field of protection of the general public from non-ion...
Article
Full-text available
The paper analyzes the levels of magnetic flux density in the apartment located above the 10/0.4 kV distribution transformer station. During the first magnetic field testing, it was concluded that in the case of the rated load of the transformers, increased values of magnetic flux density would occur in the apartment. The main sources of magnetic f...
Conference Paper
Под радом у близини напона на двосистемском надземном воду подразумева се обављање радова на систему који је искључен и адекватно уземљен (пасивни систем), док је други систем у погону (активни систем). Према важећим законским прописима адекватно уземљен систем подразумева уземљавање пасивног вода повезивањем свa три фазна проводника на стуб на ком...
Conference Paper
Испитивања електричних и магнетских поља спроведена у претходном периоду у околини надземних електроенергетских водова напонских нивоа 110 kV, 220 kV и 400 kV показала су да се у близини ових водова могу јавити значајни нивои пољâ, који у неким случајевима могу прекорачити прописане границе излагања становништва. У раду су приказане мере које се мо...
Conference Paper
U radu su analizirani nivoi električnog i magnetskog polja u okolini prenosnih nadzemnih vodova. Analiza je zasnovana na rezultatima proračuna koji je sproveden za tipične konfiguracije nadzemnih vodova naponskih nivoa 110 kV, 220 kV i 400 kV. Dobijeni rezultati su upoređeni sa granicama izlaganja stanovništva, koje su propisane važećom regulativom...
Article
Full-text available
The topic of the paper is related to the ongoing issue of exposure of the general public to high frequency electromagnetic field in the environment. The results of testings carried out in the areas of increased sensitivity located in the vicinity of base stations and radio and TV transmitters are shown in this paper. The obtained results are analyz...
Conference Paper
This paper analyzes the topical issue of the general public protection from the low frequency electric and magnetic fields i.e. from the non-ionizing radiation originating from overhead power lines. Knowing the levels of electric and magnetic fields in the vicinity of overhead power lines as well as width of their zone of influence is of great impo...
Conference Paper
У раду су приказани резултати мерења магнетске индукције у стану који се налази изнад трансформаторске станице напонског нивоа 10/0,4 kV. Приликом првог испитивања нивоа нејонизујућег зрачења у поменутом стану измерени су значајни нивои магнетске индукције. На основу односа назначене струје трансформатора и струје у време мерења закључено је да би...
Conference Paper
У раду су анализирани нивои нејонизујућег зрачења ниских учестаности у околини трансформаторских станица 110/10 kV са постројењима изолованим гасом SF6, које су смештене у централним градским зонама. У њиховој непосредној околини налазе се стамбени објекти, који се категоришу као потенцијалне зоне повећане осетљивости, као и пословни објекти. Анали...
Conference Paper
У раду су анализирани нивои магнетске индукције индустријске учестаности који се јављају у зонама повећане осетљивости у околини трансформаторских станица напонског нивоа 10/0,4 kV и 20/0,4 kV. Анализа је заснована на резултатима мерења магнетске индукције у зонама повећане осетљивости у околини већег броја трансформаторских станица поменутих напон...
Conference Paper
U radu je opisan postupak dokazivanja usaglašenosti sa propisanim granicama izlaganja stanovništva nejonizujućim zračenjima u okolini prenosnih nadzemnih elektroenergetskih vodova. Pomenuti postupak uspešno je primenjen na velikom broju ispitivanja jačine električnog polja i magnetske indukcije u okolini nadzemnih prenosnih elektroenergetskih vodov...
Article
Full-text available
The topic of the paper is related to the ongoing issue of human exposure to stray electric and magnetic fields. On the example of a 400/110 kV substation a detailed presentation of power frequency electric and magnetic field testing is provided. The obtained results are analyzed and compared with reference levels prescribed by the national legislat...
Article
Power frequency electric and magnetic field levels which occur inside 110/x kV substations are analysed in this paper in order to assess the exposure of workers to these fields. The analysis is based on the results of electric field strength and magnetic flux density measurements inside 110/x kV substations in Serbia. The measurements were performe...
Conference Paper
Full-text available
У раду су анализирани нивои електричних и магнетских пољa индустријске учестаности који се јављају у околини трансформаторских станица 400/x kV. Aнализа је заснована на приказаним резултатима мерења јачине електричног поља и магнетске индукције у околини трансформаторскe станицe 400/110 kV „Врање 4”. Добијени резултати су упоређени са референтним г...
Article
Full-text available
The levels of non-ionizing radiation (electric and magnetic fields) at power frequency, which occur near 110/x kV substations are analyzed in this paper. The results of electric field strength and magnetic flux density measurements in the vicinity of three typical substations of the aforementioned voltage level are shown. With the purpose of estima...
Article
Full-text available
Determining high frequency electromagnetic field levels in urban areas represents a very complex task, having in mind the exponential growth of the number of sources embodied in public cellular telephony systems in the past twenty years. The main goal of this paper is a representation of a practical solution in the evaluation of measurement uncerta...
Article
Full-text available
Electromagnetic fields have become omnipresent in our daily environment. Monitoring of environmental electromagnetic fields has a fundamental role in the eco-sustainable development of urban and residential areas.
Conference Paper
Full-text available
SUMMARY The levels of power frequency non-ionizing radiation which occur in the vicinity of 110/x kV substations are analyzed in this paper. The analysis is based on the results of measurements of electric field strength and magnetic flux density in the vicinity of a considerable number of substations of the aforementioned voltage level. With the...
Conference Paper
У раду су приказани резултати анализа спроведених у циљу процене могућих вредности електромоторне силе која се индукује у фазном проводнику надземног вода напонског нивоа 35 kV током појаве једнофазног земљоспоја на једном од два паралелна надземна вода напонског нивоа 400 kV. Средњенапонски дистрибутивни вод се укршта са високонапонским водовима и...
Conference Paper
The paper presents the results of the analyses performed to estimate possible values of the electromotive force induced in phase conductors of a medium voltage (MV) overhead power line during a phase-to-ground fault occurring on one of two parallel high voltage (HV) overhead power lines. The MV line lies partially parallel to the HV lines and then...
Conference Paper
Full-text available
Abstract: The paper presents methodology for determining the area in the vicinity of overhead power lines where the levels of non-ionizing radiation are significant in the context of current regulations. A brief review of national legislation in the field of non-ionizing radiation protection is given, with special emphasis on power frequency non-io...
Conference Paper
Full-text available
This paper presents a calibration of a low frequency magnetic field analyzer performed in the Calibration and Testing Laboratory of the Electrical Engineering Institute Nikola Tesla in Belgrade, Serbia. The paper describes the calibration method as well as applied reference standard for magnetic field generation. It also presents the results of the...
Conference Paper
The paper presents the testing results of power frequency non-ionizing radiation (electric field strength and magnetic flux density) in the vicinity of 35 kV overhead power lines, which are obtained by measurements and calculations. The measurements of electric field strength and magnetic flux density were performed in the vicinity of several 35 kV...
Conference Paper
The paper presents a real case of the implementation of the measures for reducing the levels of magnetic field emitted by a 10/0.4 kV substation. The 10/0.4 kV substation is located in the basement of a primary school in Belgrade, Serbia. During the first non-ionizing radiation testing, the values of the magnetic flux density which exceed the refer...
Conference Paper
Рад приказује за сада једини случај примене мера за смањење магнетске индукције коју емитује дистрибутивна трансформаторска станица 10/0,4 kV. Трансформаторска станица 10/0,4 kV бр. Б-619, назначене снаге 1000 kVA, налази се у сутерену школе у Скадарској улици бр. 35 у Београду. Прва испитивања нивоа нејонизујућих зрачења које емитује ова трансформ...
Conference Paper
Рад даје преглед и суштину домаћег законодавства у домену нејонизујућег зрачења, с освртом на његове импликације на обавезе привредних друштава за дистрибуцију електричне енергије у овој области. Предочене су и примерима илустроване активности које „Електродистрибуција Београдˮ (ЕДБ) предузима на утврђивању степена утицаја својих објеката на животн...
Conference Paper
Full-text available
The paper presents interlaboratory comparison of measuring and calculation results of electric field strength near 35 kV overhead power line, in which three testing laboratories participated. This interlaboratory comparison was performed for the purpose of ensuring confidence in the quality of testing results. Measuring and calculation results are...
Article
SUMMARYA new practical approach to the shifted frequency method for grounding impedance measurements of high-voltage substation is presented in this paper. The results obtained by the proposed method are compared with the corresponding results obtained by the transition method as well as by the heavy-current injection method. It is shown that the p...
Conference Paper
Full-text available
The paper presents a case study of the 400 kV overhead power line in the Republic of Serbia where the measures for reducing the level of non-ionizing radiation were applied. According to the Serbian legislation, the reference level of the 50 Hz electric field strength is 2 kV/m in the areas of increased sensitivity. During the first testing of non-...
Conference Paper
У раду је описан реалан случај надземног електроенергетског вода напонског нивоа 400 kV, код кога су примењене мере за смањење нивоа нејонизујућих зрачења. Првим испитивањима нејонизујућих зрачења утврђено је да је прекорачен прописани референтни гранични ниво јачине електричног поља од 2 kV/m у делу дворишта у околини стамбене куће. Као мера за см...
Conference Paper
Након изградње надземног вода ТС Лесковац 2-ТС Врање 4, напонског нивоа 400 kV било је неопходно проверити безбедносне услове према захтевима прописа. Правилник за изградњу надземних водова у члану 182 предвиђа, за водове називних напона 110 kV и више, обавезу израчунавања или мерења индукованих напона у металним и жичаним оградама, при нормалном п...
Conference Paper
У раду је анализирана заштита од нејонизујућих зрачења у пословно енергетским објектима „Електродистрибуције Београд”. Приказани су резултати испитивања јачине електричног поља и магнетске индукције ниских учестаности у неколико оваквих објеката. Домаћа регулатива прописује ограничења излагања становништва нејонизујућем зрачењу, док област безбедно...
Article
Full-text available
This paper presents the soil resistivity testing results carried out at the location designated for the construction of substation 110/35/10 kV 'Zlatibor'. Testing results show that the tested soil is double-layered. Interpretation of the results of geoelectric sounding based on a mathematical model of double-layered soil shows good matching with t...
Conference Paper
Full-text available
У раду је дат приказ резултата испитивања нивоа нејонизујућих зрачења ниских учестаности (јачине електричног поља и магнетске индукције) у околини дистрибутивних електроенергетских надземних и подземних (кабловских) водова напонског нивоа 35 kV. Дуж трасâ водова биране су локације на којима нема других објеката који би могли да утичу на нивое нејон...
Conference Paper
Full-text available
У раду je приказанo међулабораторијско поређењe резултата мерења магнетске индукције дистрибутивног надземног вода, у којем су учествовале две испитне лабораторије. Мерена величина је тренутна ефективна вредност магнетске индукције, која је мерена изотропски, истовременим мерењем све три просторне компоненте вектора поља у дискретним тренуцима врем...
Article
Full-text available
The paper presents a comparison of measured results of magnetic field near 400 kV overhead power lines obtained by three laboratories. This interlaboratory comparison was performed to ensure confidence in the quality of the test results. The measured results were analyzed with standard methods, using En number, based on which the evaluation of the...
Conference Paper
Full-text available
U radu su opisane vrste merne nesigurnosti i detaljno je objašnjen celokupan postupak izračunavanja proširene merne nesigurnosti. Takođe su navedeni parametri za koje je uočeno da utiču na proširenu mernu nesigurnost pri merenju električnog i magnetnog polja industrijske učestanosti. Sve komponente proširene merne nesigurnosti su detaljno opisane,...
Conference Paper
Full-text available
Изложеност људи нејонизујућим зрачењима (нјз) односно утицају електромагнетских поља ниских учестаности чији су извори електроенергетски објекти и могући штетни ефекти на здравље представљају веома актуелне теме имајући у виду да је ова област тек недавно законски уређена у Србији. У овом раду су описане неке од мера које је могуће применити за сма...

Network