Figure 2 - available via license: CC BY-NC-ND
Content may be subject to copyright.
Voltage map in sinus rhythm, visualized from the left atrial posterior wall using the CARTO ® system. VPID: right inferior pulmonary vein; VPIE: left inferior pulmonary vein; VPSD: right superior pulmonary vein; VPSE: left superior pulmonary vein; purple area: normal voltage; red area: low voltage.

Voltage map in sinus rhythm, visualized from the left atrial posterior wall using the CARTO ® system. VPID: right inferior pulmonary vein; VPIE: left inferior pulmonary vein; VPSD: right superior pulmonary vein; VPSE: left superior pulmonary vein; purple area: normal voltage; red area: low voltage.

Context in source publication

Context 1
... describe our initial experience with the PentaRay ® catheter (Biosense Webster, Inc.), which has five highly flexible branches and a total of 20 poles ( Figure 1). This was used for ablation of persistent AF in a 36-year-old female patient, in conjunction with the CARTO ® navigation system (Biosense Webster, Inc.), to create a three-dimensional reconstruction of the left atrium (volume 142 ml) and the PVs, which was then integrated with images obtained by computed tomography angiography (Figure 2). The PentaRay ® catheter enabled rapid acquisition of a large number of points to obtain a voltage map with high signal resolution. ...

Similar publications

Article
Full-text available
Background Although several studies have reported an association between atrial fibrillation (AF) and alcohol, the impact of alcohol consumption on the outcome after catheter ablation (CA) for AF has not been discussed. We aimed to elucidate the effect of alcohol consumption on the outcome of CA for paroxysmal AF. Methods and Results We examined 1...
Article
Full-text available
The management of atrial fibrillation has evolved significantly over the last ten years with advancements in medical and catheter ablation approaches, but these have limited success when used in isolation. Trends in the management of lifestyle modifications have surfaced, as it is now better understood that modifiable risk factors contribute signif...
Article
Full-text available
Atrial fibrillation has become the most commonly seen cardiac arrhythmia in clinical practice affecting almost 5.6 million Americans with that number expected to rise in the near future. The current literature review is aimed to assess the efficacy of catheter ablation in the treatment of patients with atrial fibrillation when compared to standard...

Citations

Thesis
Catheter ablation is increasingly used to treat atrial fibrillation (AF), the most common sustained cardiac arrhythmia encountered in clinical practice. A recent patient-tailored AF ablation therapy, giving 95% of procedural success rate, is based on the use of a multipolar mapping catheter called PentaRay. It targets areas of spatiotemporal dispersion (STD) in the atria as potential AF drivers. STD stands for a delay of the cardiac activation observed in intracardiac electrograms (EGMs) across contiguous leads.In practice, interventional cardiologists localize STD sites visually using the PentaRay multipolar mapping catheter. This thesis aims to automatically characterize and identify ablation sites in STD-based ablation of persistent AF using machine learning (ML) including deep learning (DL) techniques. In the first part, EGM recordings are classified into STD vs. non-STD groups. However, highly imbalanced dataset ratio hampers the classification performance. We tackle this issue by using adapted data augmentation techniques that help achieve good classification. The overall performance is high with values of accuracy and AUC around 90%. First, two approaches are benchmarked, feature engineering and automatic feature extraction from a time series, called maximal voltage absolute values at any of the bipoles (VAVp). Statistical features are extracted and fed to ML classifiers but no important dissimilarity is obtained between STD and non-STD categories. Results show that the supervised classification of raw VAVp time series itself into the same categories is promising with values of accuracy, AUC, sensi-tivity and specificity around 90%. Second, the classification of raw multichannel EGM recordings is performed. Shallow convolutional arithmetic circuits are investigated for their promising theoretical interest but experimental results on synthetic data are unsuccessful. Then, we move forward to more conventional supervised ML tools. We design a selection of data representations adapted to different ML and DL models, and benchmark their performance in terms of classification and computational cost. Transfer learning is also assessed. The best performance is achieved with a convolutional neural network (CNN) model for classifying raw EGM matrices. The average performance over cross-validation reaches 94% of accuracy and AUC added to an F1-score of 60%. In the second part, EGM recordings acquired during mapping are labeled ablated vs. non-ablated according to their proximity to the ablation sites then classified into the same categories. STD labels, previously defined by interventional cardiologists at the ablation procedure, are also aggregated as a prior probability in the classification task.Classification results on the test set show that a shallow CNN gives the best performance with an F1-score of 76%. Aggregating STD label does not help improve the model’s performance. Overall, this work is among the first attempts at the application of statistical analysis and ML tools to automatically identify successful ablation areas in STD-based ablation. By providing interventional cardiologists with a real-time objective measure of STD, the proposed solution offers the potential to improve the efficiency and effectiveness of this fully patient-tailored catheter ablation approach for treating persistent AF.
Article
Positioning and stabilizing a catheter at the required location inside a vessel or the heart is a complicated task in interventional cardiology. In this review we provide a structured classification of catheter stabilization mechanisms to systematically assess their challenges during cardiac interventions. Commercially available, patented, and experimental prototypes of catheters were classified with respect to their stabilizing mechanisms. Subsequently, the classification was used to define requirements for future cardiac catheters and persisting challenges in catheter stabilization. The classification showed that there are two main stabilization mechanisms: surface-based and volume-based. Surface-based mechanisms apply attachment through surface anchoring, while volume-based mechanisms make use of locking through shape or force against the vessel or cardiac wall. The classification provides insight into existing catheter stabilization mechanisms and can possibly be used as a tool for future design of catheter stabilization mechanisms to keep the catheter at a specific location during an intervention. Additionally, insight into the requirements and challenges for catheter stabilization inside the heart and vasculature can lead to the development of more dedicated systems in the future, allowing for intervention- and patient-specific instrument manipulation.
Article
Full-text available
Ablation of AF through electrical isolation of the pulmonary veins is a well-established technique and a cornerstone in the ablation of AF, although there are a variety of techniques and ablation strategies now available. However, high numbers of patients are returning to hospital after ablation procedures such as pulmonary vein isolation (PVI). Scar tissue (as identified by contact voltage mapping) is found to be present in many of these patients, especially those with persistent AF and even those with paroxysmal AF. This scarring is associated with poor outcomes after PVI. Cardiac mapping is necessary to locate triggers and substrate so that an ablation strategy can be optimised. Multipolar mapping catheters offer more information regarding the status of the tissue than standard ablation catheters. A patient-tailored catheter ablation approach, targeting the patient-specific low voltage/fibrotic substrate can lead to improved outcomes.