Threshold (Left) and ENC (Right) distributions in TJ-Monopix before and after neutron irradiation up to a fluence of 1 × 10 15 n eq /cm 2

Threshold (Left) and ENC (Right) distributions in TJ-Monopix before and after neutron irradiation up to a fluence of 1 × 10 15 n eq /cm 2

Source publication
Preprint
Full-text available
Two different depleted monolithic CMOS active pixel sensor (DMAPS) prototypes with a fully synchronous column-drain read-out architecture were designed and tested: LF-Monopix and TJ-Monopix. These chips are part of a R\&D effort towards a suitable implementation of a CMOS DMAPS for the HL-LHC ATLAS Inner Tracker. LF-Monopix was developed using a 15...

Contexts in source publication

Context 1
... means of a scan over injection DAC steps, it was possible to determine the threshold and equivalent noise charge (ENC) in TJ-Monopix from the mean and standard deviation of the resulting s-curves, respectively. The threshold and noise distributions for the RDPW region are shown in Figure 6. The threshold before irradiation had a mean around 350 e− with a dispersion of 35 e−. ...
Context 2
... means of a scan over injection DAC steps, it was possible to determine the threshold and equivalent noise charge (ENC) in TJ-Monopix from the mean and standard deviation of the resulting s-curves, respectively. The threshold and noise distributions for the RDPW region are shown in Figure 6. The threshold before irradiation had a mean around 350 e− with a dispersion of 35 e−. ...

Similar publications

Article
Full-text available
A broadband receiver front-end with low noise figure and flat conversion gain response is presented in this paper. The receiver front-end is a part of the broadband spectrum sensing receiver and processes 30–40 GHz of broad input spectrum followed by down-conversion to DC-10 GHz of IF signal. The proposed work is comprised of a low noise amplifier...