The power transformer in a substation

The power transformer in a substation

Source publication
Article
Full-text available
Insulation of the transformer is one of the essential components. So that the quality of the resistance in the isolation of the transformer is essential to note the condition, in order to find out the condition of the transformer isolation, several tests must be performed, namely the polarization index, delta tangent, and break down voltage. In thi...

Contexts in source publication

Context 1
... these transformers are placed in 500 kV, 150 kV, and power generation systems. Figure 1 shows the power transformer in a substation. ...
Context 2
... these transformers are placed in 500 kV, 150 kV, and power generation systems. Figure 1 shows the power transformer in a substation. ...

Similar publications

Preprint
Full-text available
Detection power of separability criteria based on a correlation tensor is tested within a family of generalized isotropic state in $d_1 \otimes d_2$. For $d_1 \neq d_2$ all these criteria are weaker than positive partial transposition (PPT) criterion. Interestingly, our analysis supports the recent conjecture that a criterion based on symmetrically...
Article
Full-text available
The paper proposes a new technique to mitigate the state explosion in model checking. The technique is called a divide & conquer approach to leads-to model checking. As indicated by the name, the technique is dedicated to leads-to properties. It is known that many important systems requirements can be expressed as leads-to properties, thus it is wo...
Article
Full-text available
Many design parameters are known to affect the characteristics of a substation grounding system, in terms of its quality and efficiency. The most relevant of theseparameters are soil resistivity, number of meshes within a grounding grid, and the use of grounding rods in the grid. Grounding rods may contribute to quality and efficiency of substation...

Citations

... Pengujian indeks polarisasi (IP) dilakukan pada belitan yang bertujuan untuk mengetahui keadaan isolasi antara dua belitan atau belitan dengan bumi. Pengujian ini memberikan tegangan DC dan menampilkan keadaan isolasi menggunakan satuan megaohm [11]. Pengujian ini membandingkan berupa hasil pengujian yang dilakukan pada menit ke 10 dengan hasil pengujian yang dilakukan pada menit ke 1 [12]. ...
Article
p> Transformers work around the clock to maintain the stability of power distribution to the community. If inspections and maintenance are not done, it will cause problems such as disturbances and damage, one of which is a disturbance in transformer insulation resistance caused by high operation factors, temperature, leakage current, and equipment age that can cause a decrease or damage in insulation quality. Therefore, it is important to do regular maintenance, one of which is through preventive maintenance as an effort to know the quality of insulation resistance on transformers. In this study, preventive maintenance was carried out which includes four methods, namely polarization index, tangent delta, breakdown voltage, and voltage ratio, which are useful for knowing the feasibility of insulation resistance quality with the established standards and next preventive steps. This research took data at Garuda Sakti Main Substation, the data included testing data from polarization index, tangent delta, breakdown voltage, and voltage ratio. The results of the discussion were obtained in transformer 1 and 3 were still within the allowed standard, but there were some parts of transformer insulation that experienced a decrease in quality and preventive maintenance needs to be done. The preventive maintenance step from the deterioration of the polarization index is that cleaning between windings is needed to minimize deterioration. In the breakdown voltage, further examination is needed, such as purifying in order to increase the dielectric strength of oil in the transformer. Keywords - Transformer, Isolation Resistance, Preventive Maintenance, Polarization Index. </p