Figure 4 - available via license: Creative Commons Attribution 3.0 Unported
Content may be subject to copyright.
Temperature (0:00). Figure 5. Temperature (10:00). Figure 6. Temperature (20:00).

Temperature (0:00). Figure 5. Temperature (10:00). Figure 6. Temperature (20:00).

Source publication
Article
Full-text available
The basic principle of turbogenerator stator core magnetization test is introduced, aiming at the overheated condition of stator core during magnetization test of No.1 generator in Yingkou Power Plant of Huaneng International Electric Power Co.,Ltd., the causes of hot spots in the core during the test are analyzed, the test, inspection and treatmen...

Context in source publication

Context 1
... electrical data of the second stator core magnetization test is consistent with that of the first test (as shown in Table 2). For the first test overheat position, the whole process of real-time temperature monitoring is carried out in this test, relevant data are shown in Table 4 Figure 4 10:00 54.5 See Figure 5 20:00 63.5 See Figure 6 30:00 77.7 See Figure 7 45:00 90.2 See Figure 8 55:00 94.3 See Figure 9 Note: Initial temperature: Excitation side 27 It can be seen from Table 3, Table 4 and Figure 9,after processing, the maximum temperature between 32 and 33 grooves on excitation side (axial section 1 of core) is 94.3 ℃, temperature rise 66.8K, temperature difference 57.9K, compared with the first test, the maximum temperature, temperature rise and temperature difference all decreased to a certain extent, however, it still does not meet the relevant requirements of 7.1 and 7.2 of GB / T 20835-2016 guide for magnetization test of generator stator core. ...

Similar publications

Article
Full-text available
This paper introduces the calculation method and results of the large-fluctuation transition process of the Francis hydro-generator set. The operation of the power station shows that the calculation method and results can meet the engineering requirements, but they cannot reflect the state of the unit during small fluctuations. For large-scale unit...