Figure 1 - uploaded by Evan Thomas
Content may be subject to copyright.
TOCA on the International Space Station with Astronaut Don Pettit prior to installation. Electronics module shown in top section, and fluids module with cover removed shown on bottom. 

TOCA on the International Space Station with Astronaut Don Pettit prior to installation. Electronics module shown in top section, and fluids module with cover removed shown on bottom. 

Similar publications

Article
Full-text available
Quantifying soil gas emissions is costly, since it requires specific methodologies and equipment. The objective of this study was to evaluate modeling by nonlinear regression and artificial neural networks (ANN) to estimate CO2 emissions caused by soil managements. CO2 emissions were evaluated in two different soil management systems: no-tillage an...
Conference Paper
Full-text available
Археологическая хронология для некоторых археологических памятников Восточной Европы основана в основ- ном на прямом керамики. Даты по пищевому нагару на сосудах также были получены, если это было возможно, но гораздо больше 14C датировок было получено по общего содержания органического углерода (TOCC) в че- репках. В статье обсуждается, как интерп...

Citations

Article
NASA has been developing and testing a water recovery system for over two decades to minimize the amount of water required for long duration human space missions. A key system component is the Total Organic Carbon Analyzer (TOCA) that determines if the recovered water is below the toxicology-defined health limit of 5 mg/L TOC and safe to drink. The TOCA is composed of a liquid phase loop and a gas phase loop. The TOCA employs an oxidizer to convert the organics in the liquid phase to carbon dioxide (CO2) and a liquid/gas separator to isolate the CO2 for measurement in the gas phase by infrared spectroscopy. In an effort to reduce the consumables, mass, volume and power of the system, we investigated the ability of surface-enhanced Raman spectroscopy (SERS), and Raman spectroscopy to measure 5 mg/L carbon in water. The SERS measurement employed silver colloids to increase sensitivity, while the Raman measurements used multiple mirrors to increase sensitivity. Here we present SERS measurements of CO3= at 3 mg/L carbon and Raman measurements of CO2 at 9 mg/L carbon in the effluent water of a new oxidizer being developed for a future TOCA. Both SERS and Raman can determine TOC in the liquid phase, eliminating the need for the gas phase loop and associated supplies and replacement components, which could effectively decrease the size and weight of the current TOCA by as much as 50%.