Schematic of Hu-Liao HVDC and AC parallel transmission system 

Schematic of Hu-Liao HVDC and AC parallel transmission system 

Source publication
Article
Full-text available
In this paper, transient stability analysis was focused on Hu-Liao HVDC and AC parallel transmission system. The Hu-Liao HVDC project was introduced; Simulation method and mathematic models of AC and DC systems were stu-died as well as corresponding regulators and controllers. The dynamic performance and the interaction between AC and DC systems du...

Contexts in source publication

Context 1
... following simulation was done in such an operation: 4 units for DC power sending and DC power 1800 MW. First, to research the features of additional controls for AC/DC hybrid system, simulations were calculated by three cases: that is no additional control, with TCSC forced compensation control and with DC emergency power control. Results were shown in Figure 10. When the additional control of TCSC and DC is activated, the transient stability can be improved but in a limit com- pared with unit tripping under such serious faults. ...
Context 2
... China Electric Power Network System consists of four provincial networks, Liaoning, Jilin, Heilongjiang and East of Inner Mongolia. These networks have been linked with 500 kV transmission lines. And Liaoning electric network is connected with Huabei network by back-to-back HVDC links with a rated capacity of 1500 MW. Figure 1 shows the schematic of Hu-Liao HVDC and AC parallel transmission system. Hulunbeier is rich in coal, large scale power plants are under constructing. Liaoning province is a rapid devel- oping province in economic but much lack of energy. So based on the mutual interest and the idea of optimizing resources, Hu-Liao HVDC project is put into operation. Hu-Liao HVDC transmission is a bipolar 12-pulse HVDC transmission system with rated DC voltage ± 500 kV, rated power 3000 MW, rated current 2500 A. Over- head lines have a length of 908 km long. Yimin converter station locates at east of Inner Mongolia, which is 10 km away from Yimin power plants. It acts normally as a rec- tifier and its AC side rated voltage is 500 kV. Mujia con- verter station is in the center of Liaoning province and connected with Anshan 500 kV station with two 21 km lines. It acts principally as an inverter and its AC side rated voltage is also 500 kV. The Hu-Liao HVDC trans- mission system operation modes include bipolar mode, monopolar ground return mode, monopolar metallic re- turn model and monopolar parallel line ground return model. The HVDC system can be operated under rated voltage and lower voltage. The Hu-Liao HVDC trans- mission normally operates in P mode (constant power control mode). I mode (constant current control mode) can be used as a back-up ...

Similar publications

Article
Full-text available
The stability of Modular multilevel converter (MMC) itself is the premise of analyzing the stability of MMC cascading with other cells, so this paper addressed the small-signal stability of MMC with dc voltage control mode which is the common operation mode of grid-side MMC in high-voltage direct current (HVDC) systems. First, the small signal mode...
Article
Full-text available
With the increase in number of VSC based HVDC systems, it is inevitable that there would be interconnections with weak ac grids. The paper presents the analytical basis for identifying coupling in the power loops which is dependent on grid inductance and operating point by utilizing the impedance-based modeling technique. The formulation is used to...
Article
Full-text available
The paper discusses the impact of multiple time delays on the stability of centralized wide area damping controllers (WADCs). These controllers are utilized in electric power systems to damp the interarea oscillations. With this aim, an ideal WADC is first designed based on the well-known H∞ control scheme. Then delays are included for all remote s...
Article
Full-text available
Large signal stability is mainly defined as the system stability following a large disturbance such as three phase short circuit or line disconnection. It is useful to study the effects of reactive loads on the large signal stability of power system as a rarely investigated issue. In this regard, this paper deals with large signal stability analysi...
Article
Full-text available
Regenerative chatter can reduce machining quality, tool life, and productivity during milling process. In order to control the milling chatter, the stability analysis of milling system is very important. It has been found that variable spindle speed milling and the use of variable-angle tools are effective to control milling chatter. This paper mai...

Citations

... Due to the freewheeling diodes feeding the DC fault, a strong AC grid current flows through them, potentially damaging the converter valves. Recently, protecting HVDC transmission lines using VSC has proven to be very difficult [13][14][15]. ...
... The HVDC transmission is widely recognized for delivery large blocks of energy over long distances, asynchronous interconnection and for energy transmission by submarine cables. The actual number of HVDC projects under consideration or in application around the world has increased at last years, reflecting a renewed interest in this technology [3] [4]. ...
Article
Full-text available
Segmentation of large AC systems through DC links introduces a new concept that utilizes the advantages of direct current transmission to improve network reliability and increase power transfer capacity. Technical literature argues that the segmentation of the AC network and the introduction of DC links at these systems connection points bring benefits to system operation, once contingencies generated on one side of the DC connection point would not be reflected on the other side of DC connection, thereby reducing the likelihood of cascading shutdowns and blackouts due to load restraint on transmission lines and transformers. Amidst this scenario, this paper presents a study of the main topics regarding the use of this new network segmentation philosophy, bringing a practical point of view for the use of this concept at the electrical power system planning. The effect of DC segmentation before a contingency that would initiate major outages in an adapted electrical system model IEEE-14 bus is studied and simulations have been performed with test HVAC systems and segmented by HVDC link. The results have been compared, principally in relation to the voltage bus, reactive power generation, system losses and power flow at the lines, and demonstrated that this new concept improved the grid reliability.
Conference Paper
Combined with an HVDC transmission system closely, the voltage stability of the system is studied which is based on the sensitivity analysis method. First, a hybrid HVDC system sensitivity calculation method is deduced. On the basis of the method, the active and reactive power sensitivity matrix which is about the voltage amplitude of several AC transmission system important nodes to the DC channel and AC channel is calculated. The sensitivity matrix of the transmission active power and the absorbed reactive power of DC system is calculated under different control modes of DC system, as well as several important nodes voltage sensitivity under different control mode. Integrated the sensitivity indicators above, the operation control mode of AC/DC hybrid transmission system and the measures to improve the voltage stability are studied, providing the technical reference for the safe and stable operation of AC/DC hybrid transmission system.
Article
The characteristics of Korean power systems are large capacity of generation sites and concentrated load in Seoul metropolitan area. According to the national generation facility plan, more generation facilities are needed to be constructed as the electrical demands are forecasted to increase. Moreover, the size of generation sites are expected to increase, too. Therefore transient stability problems become worse and worse. Recently, the necessity of HVDC has been raised to overcome the difficulty of constructing HVAC transmission lines. This paper shows the analysis of transient stability when HVDC transmission system is added to the power system consisting of large generation sites.