Power Loss Without STATCOM Installation

Power Loss Without STATCOM Installation

Source publication
Article
Full-text available
ABSTRAK Pertumbuhan ekonomi di indonesia berbanding lurus dengan permintaan energi listrik di masyarakat yang terus meningkat. Dampaknya adalah sistem tenaga listrik akan menimbulkan berbagai masalah dalam penyaluran energi listrik, seperti drop tegangan diluar batas yang diijinkan, dan rugi rugi daya bertambah besar pada saluran. Salah satu solus...

Context in source publication

Context 1
... 4 can be seen that many buses are outside the S-PLN voltage limit with the buses that are farthest from the SPLN, namely buses 50 and 51 with a voltage value of 1,130 p.u on each bus, and buses 58 and 59 with a voltage value of 1,090 p.u. on each bus. As for the value of the power flow loss in the initial condition system without any reactive power compensation, it is shown in Table 2 below: ...

Similar publications

Preprint
Full-text available
In this paper, two wind power farms are proposed to produce the active power using two variable profiles of the wind. Indeed, in order to ensure the proper functioning of the electrical power system, two FACTS devices are installed in series between buses 1 and 3, separately. The effects of disturbances, in the form of variable profiles of the wind...
Article
Full-text available
Various Flexible Alternating Current Transmission System (FACTS) devices are used to improve the power quality and reliability of power system. In addition to the technical constraints, the installation and maintenance costs limit the exploitation of such devices. To maximize the efficiency of FACTS, the least possible number of devices must be pla...
Article
Full-text available
Over the last two decades, voltage instability problem in power systems have become one of the most important concerns in the power industry. Recently, several network blackouts have been related to voltage collapse. The introduction of emerging Flexible AC Transmission Systems (FACTS) technology improves the Stability, reduces the losses and also...
Article
Full-text available
Flexible AC transmission systems (FACTS) are a viable way to improve power system performance because of the rapid advancement of power electronic technology. Improvement of dynamic and transient stability, voltage control, voltage stability improvement, power factor correction, enhancement of `power profile, an increase in the transmission line’s...
Article
Full-text available
Introduction. Power planning and management of practical power systems considering the integration and coordination of various FACTS devices is a vital research area. Recently, several metaheuristic methods have been developed and applied to solve various optimization problems. Among these methods, an artificial ecosystem based optimization has bee...

Citations

... Also, the weakest bus bar can be specified by the total power loss calculation, wich demonstrate in table (2). The STATCOM is connected to the load buses (3,5,7,9,10,11,12,13,15,16,17,18,19,20,21,22,23,24 ) individually, with each connection made to a single bus-bar. For each connection, the ratio of total active power losses to total active power generation is recorded. ...
... [11][12][13][14][15][16]: ...
Article
Full-text available
The importance of power system operation is becoming increasingly significant due to the escalating demand observed in many nations. The exponential growth in load demand exerts substantial stress on electrical power systems, since they run in close proximity to their critical thresholds due to limitations imposed by environmental and economic factors. The basic goal of operating electrical power networks is to efficiently supply energy to users at optimal frequency and voltage levels, with a focus on cost minimization. The main objective of this study is to examine the augmentation of voltage stability margin by deploying Flexible AC Transmission Systems (FACTS) at their ideal positions. In order to determine the most efficient size of a Static Synchronous Compensator (STATCOM), it is necessary to explore the relationship between the loading factor and the capacity of the STATCOM. The case study utilized the Iraqi National Super Grid System (INSGS), which consisted of a 24-bus configuration. The effectiveness of the CPF technique has been assessed in the framework of the Iraqi Super Grid test System. The appropriate place for attaching STATCOM to enhance voltage stability in the Iraqi network system was identified to be Bus (20).