Figure 1 - uploaded by Athanasios Kanatas
Content may be subject to copyright.
Illustration of the hardware setup.  

Illustration of the hardware setup.  

Source publication
Article
Full-text available
This paper presents results from an indoor LOS channel measurement campaign at the 60GHz band. The results include the Ricean K-factor and time dispersion/frequency selectivity characteristics, which dominate the data-rate and error-performance limitations of the channel. Finally, three clusters are identified and the well known Saleh-Valenzuela mo...

Context in source publication

Context 1
... of the measurement system was 625 kHz, since 1601 frequency tones were transmitted in a bandwidth of 1 GHz. The bandwidth of the measurement system was limited by the bandwidth of the LNA used at the receiver. The corresponding time resolution is 1nsec and the maximum measured excess delay is 1600 nsec. The hardware setup is illustrated on Fig. 1 [4]. ...

Similar publications

Conference Paper
Full-text available
This paper is devoted the evaluation of power permeation to MS from BS that is in neighbouring sector. The basis for the analysis is the power azimuth spectrum (PAS) that describes the angle distribution of the signal power at the input of receiver. The results of the numerous measurements show that with the increase of the environment urbanization...

Citations

... researchers can evaluate the feasibility, performance, and potential benefits and applications of deploying high-speed wireless systems (4,5). The present study used real-time data from an experiment in an ICU scenario to resolve the technical difficulties of growing and expanding emergency care needs in terms of fast data transmission and diagnosis, speed, computation capability, fast wireless communication, big data analysis, and massive storage (Figure 1 A & B) (6)(7)(8). ...
Article
Full-text available
About 795,000 people die or are permanently disabled each year due to diagnostic errors and related harms across clinical settings, according to estimates based on nationally representative disease incidence data for 2012 to 2014 (1). Studies show that the number of medical errors is increasing annually (2). This undergoing research study has its impact on improving human healthcare and reducing diagnostic errors due to fast, accurate, and robust data storage, transmission, and analysis with the use of information technology (IT) (3).
... Thus, 60 GHz WDC links can potentially match the wired DCN in terms of performance, without the downsides of logistics and cost challenges. Transmission mechanisms and system design at 60 GHz are strongly dependent on the propagation environment, due to the small wavelength (λ = 5 mm) [10]. 60 GHz radio links are heavily attenuated, and signals are distorted by reflected and scattered multipath components (MPCs) [11]. ...
Article
Full-text available
This paper presents a set of statistical channel models based on 60 GHz radio measurements in a server room. The channel models are developed for possible use-cases, corresponding to potential deployment scenarios in wireless data centers (WDCs). A simple parametric channel model is used to model both the deterministic and stochastic channel parameters in the delay domain, within the 57–64 GHz unlicensed band. A simulation framework is accordingly provided to generate channel realizations for WDC use cases. The accuracy of the simulation framework is verified using the delay spread as a validation metric. The reported models are useful for practical system design and evaluation of WDCs millimeter-wave systems.