Flow Cycle Criteria and Brand Names on Some Common Mechanical Ventilators

Flow Cycle Criteria and Brand Names on Some Common Mechanical Ventilators

Source publication
Article
Full-text available
Patient-ventilator interaction is a key element in optimizing mechanical ventilation. The change from inspiration to expiration is a crucial point in the mechanically ventilated breath, and is termed "cycling." Patient-ventilator asynchrony may occur if the flow at which the ventilator cycles to exhalation does not coincide with the termination of...

Context in source publication

Context 1
... numerous accounts of expiratory asynchrony, mechanical ventilator manufacturers created features that allow adjustment of flow cycling. The PSV flow-cycle threshold is adjustable on current mechanical ventila- tors, and the flow-cycling setting has various trade names (Table 1), though none of them are referred to as "flow- cycle threshold," which adds to the confusion of termi- nology related to mechanical ventilators. The flow-cy- cling criterion is different on various ventilators, with a range of 1-80% of peak flow. ...

Similar publications

Article
Full-text available
Objective: To determine the efficacy of lung hyperinflation maneuvers via a mechanical ventilator compared to isolated tracheal aspiration for removing secretions, normalizing hemodynamics and improving lung mechanics in patients on mechanical ventilation. Methods: This was a randomized crossover clinical trial including patients admitted to the...
Article
Full-text available
BACKGROUND AND OBJECTIVES: The mechanical ventilator support is one of the main used modalities of support in intensive therapy. In the modality of predetermined pressure, the maximum pressure is regulated, but the current volume (V T) is a complex function of the applied pressure and its speed to reach the pressure-target, of the available breathi...
Article
Full-text available
Background and objectives: The mechanical ventilator support is one of the main used modalities of support in intensive therapy. In the modality of predetermined pressure, the maximum pressure is regulated, but the current volume (V T) is a complex function of the applied pressure and its speed to reach the pressure-target, of the available breath...
Article
Full-text available
Objective: To evaluate the most recent transport ventilators' operational performance regarding volume delivery in controlled mode, trigger function, and the quality of pressurization in pressure support mode. Methods: Eight recent transport ventilators were included in a bench study in order to evaluate their accuracy to deliver a set tidal vol...

Citations

... Also, the robustness of software and hardware of each ventilator ought to be assessed under high load. Last, the patient cycling that describes the transition from inspiration to expiration during assisted ventilation (25) was not measured in this study. ...
Article
Full-text available
Aiming to address clinical requirements subsequent to SARS-CoV-2-related pulmonary disease, multiple research groups and industry groups carried out intensive studies to develop pandemic ventilators (PDVs). In vitro testing to critically evaluate the specific performance of the developed apparatuses is an essential requirement. This study presents a test protocol which promotes a test-oriented, iterative, and agile assessment and consecutive development of such PDVs. It allows for fast identification of specific characteristics of each PDV in the individual test features. The test protocol includes an evaluation of the accuracy of control systems and instruments at changing parameters, the oxygen dynamics, and the response to trigger signals. The test environment is a mechanical lung, which allows reproducing various lung mechanics and to simulate active breathing cycles. A total of three PDVs that are under development were iteratively tested, with a Hamilton T1 as a reference. Continuous testing of the PDVs under development enables quick identification of critical application aspects that deserve further improved. Based on the present test protocol, the ventilators demonstrate a promising performance justifying continued development.
... Управление дыхательным циклом реализуется микро процессорами современных респираторов посредством анализа динамики ряда параметров, по достижении опре деленных величин которых происходит переключение с вдоха на выдох. Эти параметры называют «циклическими переменными»: 1) давление -переключение происходит при достиже нии заданного уровня давления (контроль подъема давления в дыхательных путях до опасных значений); 2) время -переключение происходит при достижении заданной продолжительности фазы вдоха (определяет отношение вдох / выдох, возможен обратный алгоритм); 3) объем -переключение происходит при достижении заданного ДО; 4) поток -переключение происходит при снижении пико вой скорости инспираторного потока до определенного значения (заданного в процентах от максимальной ско рости пикового инспираторного потока в большинстве аппаратов ИВЛ [18,22]. ...
Article
Asynchronies (desynchronies, dyssynchrony) is a disturbance of the harmonious interaction between the patient’s respiratory system and а ventilator. Asynchronies occur as a result of various reasons and with any form of respiratory support (non-invasive, assisted or fully controlled mechanical ventilation). Asynchrony is a significant cause of biomechanics and gas exchange disorders in the development of both self-injury and ventilator-induced lung injury, an increase of the respiratory support duration and mortality in patients with respiratory failure. Understanding the mechanisms of the asynchrony pathogenesis and assessment of the patient’s respiratory system condition make it possible to timely identify and resolve disturbance of the patient-ventilator interactions. The article presents a classification, the main causes of development, diagnostic and correction methods of different variants of desynchronies in patients with respiratory disorders during of respiratory support.
... Cycling dyssynchrony happens when the neural TI and the ventilator TI are mismatched [21,34]. ...
Article
Full-text available
Patient–ventilator dyssynchrony is a mismatch between the patient’s respiratory efforts and mechanical ventilator delivery. Dyssynchrony can occur at any phase throughout the respiratory cycle. There are different types of dyssynchrony with different mechanisms and different potential management: trigger dyssynchrony (ineffective efforts, autotriggering, and double triggering); flow dyssynchrony, which happens during the inspiratory phase; and cycling dyssynchrony (premature cycling and delayed cycling). Dyssynchrony has been associated with patient outcomes. Thus, it is important to recognize and address these dyssynchronies at the bedside. Patient–ventilator dyssynchrony can be detected by carefully scrutinizing the airway pressure–time and flow–time waveforms displayed on the ventilator screens along with assessing the patient’s comfort. Clinicians need to know how to depict these dyssynchronies at the bedside. This review aims to define the different types of dyssynchrony and then discuss the evidence for their relationship with patient outcomes and address their potential management.
... These last two limitations are assumed to be a source for increasing the inter-rater variability (32). Since "minor" AEs as advanced and delayed cycling (pressure release) (42,43) are not detected by the SyncSmart software, they were not considered in this study. As they are suspected to be important for inducing major AEs, detecting them would lead to a better understanding of the causes of the main events. ...
Article
Full-text available
Background: Patient-ventilator synchronization during non-invasive ventilation (NIV) can be assessed by visual inspection of flow and pressure waveforms but it remains time consuming and there is a large inter-rater variability, even among expert physicians. SyncSmart ™ software developed by Breas Medical (Mölnycke, Sweden) provides an automatic detection and scoring of patient-ventilator asynchrony to help physicians in their daily clinical practice. This study was designed to assess performance of the automatic scoring by the SyncSmart software using expert clinicians as a reference in patient with chronic respiratory failure receiving NIV. Methods: From nine patients, 20 min data sets were analyzed automatically by SyncSmart software and reviewed by nine expert physicians who were asked to score auto-triggering (AT), double-triggering (DT), and ineffective efforts (IE). The study procedure was similar to the one commonly used for validating the automatic sleep scoring technique. For each patient, the asynchrony index was computed by automatic scoring and each expert, respectively. Considering successively each expert scoring as a reference, sensitivity, specificity, positive predictive value (PPV), κ-coefficients, and agreement were calculated. Results: The asynchrony index assessed by SynSmart was not significantly different from the one assessed by the experts (18.9 ± 17.7 vs. 12.8 ± 9.4, p = 0.19). When compared to an expert, the sensitivity and specificity provided by SyncSmart for DT, AT, and IE were significantly greater than those provided by an expert when compared to another expert. Conclusions: SyncSmart software is able to score asynchrony events within the inter-rater variability. When the breathing frequency is not too high (<24), it therefore provides a reliable assessment of patient-ventilator asynchrony; AT is over detected otherwise.
... These techniques can provide robust information and help clinician detection of PVA but are quite complex to employ, requiring dedicated equipment and specialized expertise. As such these tools are not routinely used in clinical practice (6,20,(21)(22)(23)(24). Furthermore, automated PVA detection has not been validated in large, heterogeneous populations and remains restricted mostly to research protocols (6,21,24,25). ...
Preprint
Full-text available
Background: Patient-ventilator asynchrony (PVA) is commonly encountered during mechanical ventilation of critically ill patients. Estimates of PVA incidence vary widely. Type, risk factors, and consequences of PVA remain unclear. We aimed to measure the incidence and identify types of PVA, characterize risk factors for development, and explore the relationship between PVA and outcome among critically ill, mechanically ventilated adult patients admitted to medical, surgical, and medical-surgical intensive care units in a large academic institution staffed with varying provider training background. Methods: A single center, retrospective cohort study of all adult critically ill patients undergoing invasive mechanical ventilation for ≥12 hours. Results: A total of 676 patients who underwent 696 episodes of mechanical ventilation were included. Overall PVA occurred in 170 (24%) episodes. Double triggering 92(13%) was most common, followed by flow starvation 73(10%). A history of smoking, and pneumonia, sepsis, or ARDS were risk factors for overall PVA and double triggering (all P<0.05). Compared with volume targeted ventilation, pressure targeted ventilation decreased the occurrence of events (all P<0.01). During volume controlled synchronized intermittent mandatory ventilation and pressure targeted ventilation, ventilator settings were associated with the incidence of overall PVA. The number of overall PVA, as well as double triggering and flow starvation specifically, were associated with worse outcomes and fewer hospital-free days (all P<0.01). Conclusion: Double triggering and flow starvation are the most common PVA among critically ill, mechanically ventilated patients. Overall incidence as well as double triggering and flow starvation PVA specifically, portend worse outcome.
... Mechanical insufflation continues after neural inspiration has ceased or even during active expiration. Most frequent causes are an inappropriate timing in cycling setting (17) and airleaks (44,45). Chronic obstructive pulmonary disease (COPD) and asthma are risk factors for delayed cycling, and the shorter expiratory time contributes to worsening hyperinflation in these patients (46). ...
Article
Full-text available
Background: Mechanical ventilation is often employed as partial ventilatory support where both the patient and the ventilator work together. The ventilator settings should be adjusted to maintain a harmonious patient–ventilator interaction. However, this balance is often altered by many factors able to generate a patient ventilator asynchrony (PVA). The aims of this review were: to identify PVAs, their typologies and classifications; to describe how and to what extent their occurrence can affect the patients’ outcomes; to investigate the levels of nursing skill in detecting PVAs. Methods: Literature review performed on Cochrane Library, Medline and CINAHL databases. Results: 1610 records were identified; 43 records were included after double blind screening. PVAs have been classified with respect to the phase of the respiratory cycle or based on the circumstance of occurrence. There is agreement on the existence of 7 types of PVAs: ineffective effort, double trigger, premature cycling, delayed cycling, reverse triggering, flow starvation and auto-cycling. PVAs can be identified through the ventilator graphics monitoring of pressure and flow waveforms. The influence on patient outcomes varies greatly among studies but PVAs are mostly associated with poorer outcomes. Adequately trained nurses can learn and retain how to correctly detect PVAs. Conclusions: Since its challenging interpretation and the potential advantages of its implementation, ventilator graphics monitoring can be classified as an advanced competence for ICU nurses. The knowledge and skills to adequately manage PVAs should be provided by specific post-graduate university courses.
... With volume cycling, inspiration is terminated and the passive process of expiration allowed to occur once the target tidal volume has been delivered. Time cycling (inspiratory phase lasts for a set period of time), pressure cycling (inspiration ends once a set pressure has been reached) and flow cycling (inspiration switches to expiration once gas flow falls below a set level) are also used (Gentile, 2011). ...
Article
Full-text available
Caring for a mechanically ventilated patient can be a daunting task for medical trainees. This article provides a simple guide to mechanical ventilation, aimed at the non-anaesthetist. The most common modes of ventilation are clearly explained and key terms, including resistance and compliance defined. A practical guide to assessing a mechanically ventilated patient on a ward round is provided. Common ventilator-associated problems are also discussed, with troubleshooting tips.
... This means that the system continues in the inspiratory phase, once the patient's inspiratory effort has ended, which decreases the time available for the expiratory phase. This may produce an activation of the patient's expiratory muscles before the established cycling criteria (active exhalation), air trapping, dynamic hyperinflation and PEEPi, which may increase the work of breathing and cause ineffective efforts [32][33][34]. Parthasarathy et al mentioned that "a delay in relaxation of the expiratory muscles could cause them to remain active during the early phase of the next inspiration, and by opposing the downward motion of the diaphragm could hinder the efficacy of the subsequent inspiratory effort." This type of asynchrony is common in COPD patients because of PEEPi and a short expiratory time. ...
... This type of asynchrony is common in COPD patients because of PEEPi and a short expiratory time. In these cases, an effective solution would be decreasing the inspiratory time in controlled modes such as pressure assist/control ventilation and Synchronized Intermittent Mandatory Ventilation (SIMV) [33,34]. The inspiratory time can be decrease, also, by modifying the cycling criteria in pressure support ventilation [23]. ...
Article
Full-text available
A significant percentage of mechanically ventilated patients in Intensive Care Units (ICUs) show some type of patient-ventilator asynchrony (PVA). The presence of PVA is associated with complications that affect the clinical outcome and the goals for which mechanical ventilation is used in critically ill patients. Currently, mechanical ventilators are able to show different types of waveforms that allow to identify the different types of PVA in a noninvasive and reliable way. However, in order to perform an adequate interpretation and management of the PVA the health care professionals must be properly trained in the topic.
... The results in longer inspiratory times compared to using constant flow. Longer inspiratory times can lead to delayed cycling, which can cause increased muscle workload, and ineffective efforts (11). Patients were switched to pressure support only to perform a spontaneous breathing trial (SBT), and if they failed, they were returned to the previous volume-assist control settings. ...
... Erken sonlandırma hastanın inspirasyon ihtiyacı devam ederken ventilatör tarafından asiste edilen inspirasyonun sonlandırılmasıdır. Gecikmiş sonlan-dırma ise hastanın ekshalasyon isteğine karşın ventilatörün inspiratuar akıma devam etmesidir (14) . ...