Each 1 mm thick sampled was cured in five different poles: right upper, right lower, left lower (as shown in this figure), left upper and central zone 

Each 1 mm thick sampled was cured in five different poles: right upper, right lower, left lower (as shown in this figure), left upper and central zone 

Source publication
Article
Full-text available
Aim: Light curing of resin composites may considerably change the color of resin composites. The aim of this study was to evaluate the changing pattern of resin composite's color by different curing times. Materials and methods: Fifteen, 1 mm-thick, samples of each A2 shade Clearfill and Filtek P60 composites were prepared. First five samples we...

Context in source publication

Context 1
... match of tooth-colored restorative materials is of great concern for both the clinician and patient. During polymerization, double carbon-carbon bonds would be changed into the single-bonded spatial structure which permits elongation and polymerization of the resin composite. 1 It is postulated that the color of resin composites would be changed by the progression of polymerization. 2 Photoinitiator, camphorquinone, would be eventually invisible; hence the yellowness of resin composite would be diminished along with an increased blue chroma. 2,3 Even after the completion of polymerization, resin composites undergo further changes in mouth by hydrophilic volumetric changes, Hydrolysis, stains and alteration of surface smoothness. 1,4,5 Overly, determination of color changes may be accomplished with either visual method applying a color shade or quantitavely with a device (e.g. colorimetric or spectrophotometric method). 6 Thereafter, calculated color changes may be presented by two well-known systems: Munsell (Nickerson formula) or CIE systems. 7 Although color stability of resin composites with various energy sources and immersion medias is vastly studied, limited information regarding immediate color change of direct resin composite exists in literature. 8-10 Changing pattern of resin composites with different curing times is not studied yet, as aimed in the present research to be investigated. Fifteen, 1 mm thick, samples of each A 2- shade Filtek P60 (3M/ESPE, St Paul, MN, USA) and Clearfil (Kuraray, Tokyo, Japan) resin composites were prepared using a 15×15×1 brass mold. Light curing was accomplished by a quartz-tungsten-halogen (QTC) source by three protocols with a continuous irradiation manner of 400 mW/cm 2 intensity. First five samples were cured 10 s in each pole of the rectangular samples (right upper, right lower, left lower, left upper plus central zone; Fig. 1). Consecutive sets of samples, each consists of five, were irradiated by doubling and tripling the curing time for each quadrant and the central zone to 20 and 30s with the same intensity. Deficient samples with large apparent voids, confirmed by the radiography, were discarded. Each set of samples were located on a paper and they were digitalized using a 12 megapixel digital camera (Canon, Ixus, Japan) held in position with a holder in suitable distance for a maximum contrast. The process was performed in a dark room with two 60 W light sources from sides toward the samples. Captured pictures were saved in JPEG format. 11 Thereafter, CIE 1976 L*a*b of each sample was measured with Adobe Photoshop (CS8) software using eye dropper option calculated for average obtained from five aforementioned poles. In addition, colorimetric changes (  E) were measured using CIE equation: (  E)= [(  L) 2 +(  a) 2 +(  b) 2 ] 1/2 . In CIE method ‘L’ presents brightness, ‘a’ presents reddish (+a) or greenish (–a) and ‘b’ displays yellowness (+b) or bluish (–b). Data calculated for L*a*b were tested with a general linear model (GLM) repeated measure ANOVA to detect the pattern of changes over the time. A Mauchly’s test of sphericity was used and data was reported with a Greenhouse-Geisser adjustment. Multiple comparisons were performed to compare CIE components between different curing times with Bonferroni adjustment. Moreover, a linear regression model with backward method was build to elucidate by which of ‘L’ or ‘a’ or ‘b’ changes,  E is better predictable. A two-tailed p < 0.05 was considered statistically significant. Alterations of CIE components calculated for each sample considering different light-curing regimens are displayed in Table 1 and Figure 2. Overly, ‘L’ F(2,10) = 17.63, p < 0.001 eta squared: 0.779, ‘a’ F(2,10) = 90.16, p < 0.001 eta squared: 0.948 and ‘b’ F(2,10) = 405, p < 0.001, eta squared: 0.992 components were changed statistically significant by increased curing time. Also, 2 by 2 comparisons revealed remarkable changes for 10 to 20s, 20 to 30s and 10 to 30s cured samples in terms of ‘L’, ‘a’ and ‘b’ changes (p < 0.05) except for ‘L’ changes comparing 20 to 10s cured samples (p = 0.23). The higher eta squared of ‘b’ was confirmed by a linear regression model to predict color changes with either ‘L’ or ‘a’ or ‘b’ (r = 1, p < 0.001). The present research studied the immediate color changes of Clearfil and Filtek P60 composites after 10 to 30s light curing. Findings elucidated that certain components of color in CIE system may be changed by the progression of polymerization. Moreover, in agreement with Celik et al polymerization induced perceptible color change of both studied resin composites. 12 Final color has slightly reduced yellow chroma. This outcome was in commitment with a previous report. 2 As previously mentioned, after initiation of polymerization, camphorquinone would lose its yellowness. 1 Nevertheless, interesting changes occurred by the midway during polymerization. All CIE color components were increased during 10 to 20s followed by a considerable reduction at 30s. Finally, reddish and brightness were increased and yellowness was reduced. Contra direction of the changes in color elements may be sought elsewhere. Reviewing kinetic of polymerization, changes of ion viscosity in polymer networks is of interest. Steinhaus et al investigated the real-time polymer ion viscosity (μ) changes during light curing. 13 By dielectric analysis (DEA) method, an initial drop to reach a minimum ion viscosity (log μ min ) was clarified that was followed by a slope increase to reach the saturation level (log μ). The amount of initial decrease and its duration was correlated with the thickness of resin composite. This is explained by retarding effect of dental composite stabilizer reaction with free radicals. 1 A probable answer to the unique pattern of color changes may be related to reaction of such stabilizers with initiators and free radicals at first when transient gel matrix is been formed. This final color change is not influenced by the shade of resin composite and initial ‘b’ quantity. 1 We obtained color changes applying CIE system and Photoshop software. A  E of more than 0.5 is visible and is clinically significant, if  E is greater than 3.3 score. 7 Photoshop software was used due to its ease of access and performance. In addition, previously it was validated for such purposes. 11,14 The present research has many limitations. First, immediate postcuring color changes was assessed. Nevertheless, postcuring polymerization may last up to several days. 15 Second, more precise spectrophotometric assay may better reveal the color changes. Third, color instability within mouth is influenced by many other confounders which are not taken into account in this in vitro investigation. A few structural and process modifications are suggested as the following. First, humidity resorbsion is introduced as one certain confounder against the composite color instability. Water may penetrate the polymer matrix and degrade the inner structure in addition to roughening the outer surface. 1 Hence, less hydrophilic monomer like Bis EMA (ethoxylated Bis -GMA) may maintain better color stability. 1 Second, photoinitiator, camphorquinone which absorbs at 486 nm, a visible wavelength, has a remarkable esthetic drawback. It possesses yellowness due to its unbleachable chromophore group which rise to unpleasant yellow color to the composite. Accordingly, diluting its concentration with p-octyloxy-phenyl-phenyliodonium hexafluoroantimonate (OPPI), an initiator works at invisible wavelength of 300 to 380 nm, may improve both initial color and color stability. 16 Third, it is noteworthy to mention that overirradiation may lead to polymer matrix destruction and increased yellowness of cured composites. So appropriate wavelength, power and duration are warranted. 10 A real-time spectrophotometric evaluation along with DEA following of structural changes of resin composites by various curing protocols is recommended for future investigations. Briefly, Clearfil and Filtek P60 resin composites exhibited considerable clinical significant alteration in color elements and visible color during- and postpolymerization with conventional photocuring method. According to our findings, photocuring would cause an increased chroma and a diminished yellowness of resin composites. A common practice is to cure a small piece of resin composite on the buccal surface of tooth to be restored in order to ensure maximized final color match. 12 Hence, importance of complete curing of sample composite on the buccal surface of tooth is reminded. Clinician should be aware of such remarkable color differences, if the sample composite is undercured (e.g. conventional light curing for just 20s), a not uncommon mishaps in routine practice. The author acknowledge Homatoon Alaghemand DDS, MS, Faculty Dean and Head of Dental Materials Research Center for his kindness for the materials and administrative ...

Similar publications

Article
Full-text available
Background. Selecting features for classifying objects in digital images of microscopic preparations, stained by the method of Ziehl-Nielsen with the use of methods for evaluating the informativeness of the Shannon and Kullback, and a comparison of the results of their application. Materials and methods. Used data on 343 687 the selected objects o...

Citations

Article
Full-text available
Background: Despite the improvements in optical properties of composite resins, their color stability is still a matter of concern. This study aimed to assess the curing time and intensity and polishing technique on color stability of bleach-shade composite resins. Materials and Methods: In this in vitro, experimental study, 128 discs (1 mm × 8 mm) were fabricated from two composite resins. The specimens fabricated from each composite were assigned to 8 subgroups (n = 8) based on the curing time and intensity and polishing with polishing points or discs. After polishing, the color parameters of specimens were measured by EasyShade spectrophotometer according to the CIEL* a*b* color system. The specimens were then immersed in tea solution, and their color parameters were measured again. Color change (ΔE) was calculated and analyzed at 0.05 level of significance. SPSS 25 was used for data analysis. Univariate four-way ANOVA was applied to assess the effects of composite type, curing time, curing intensity, and technique of polishing on ΔE of composite resins. Since the interaction effects were significant, subgroup analysis was performed by t-test. The level of significance for this test was set at 0.05. Results: The effects of curing intensity and polishing technique were significant on ΔE (P < 0.05). Filtek Z350 XBW composite specimens polished by polishing points experienced lower color change than those polished with discs. The minimum ΔE of Gradia XBW composite was recorded in specimens that underwent high-intensity curing for 20 s and were polished with polishing points while the maximum ΔE was recorded in specimens that underwent high-intensity curing for 20 s and were polished with discs. Conclusion: In all groups except on (Filtek, polishing with Disk, curing time = 20 s), high-intensity curing and polishing with polishing points were more effective and caused lower color change compared with low-intensity curing and polishing with discs.
Article
Nanofiller has been used these years because it has smooth particles which will give good effect in esthetic. Failure or success of restoration depends on shade stability. The stability depends on adequate polymerization. Curing process is an important aspect to initiate polymerization. The aim of this study was to evaluate the differences of the shade between nanofiller composite resin irradiation with different curing time and also the effect of different curing time on shade of nanofiller resin composite immersed in tea solution. This research used 60 disks with 6 mm in diameter and 2 mm in thickness composite for 6 kind of acts. Group are cured for 20, 30, and 40 seconds that soaked in artificial saliva for 24 hours at 37oC and also in tea solution for 72 hours. The gradation of the shade were measured with spectrophotometry. The statistical analysis that used two way Anova showed that there was no significantly difference in shade of nanofiller composite resin irradiated with different curing times that soaked in tea solution (p>0,05) and there were significantly differences among irradiation in 20 seconds soaked in tea and saliva with irradiation group of 30 and 40 seconds (p<0.05).