Beam-column joint is considered a critical region in a structure when subjected to seismic loading. Past earthquakes have shown that many of these structures behaved poorly and exhibited a combination of brittle failure at the joint and pullout of the beam longitudinal rebar, leading to a rapid degradation of the joint and a precursor to a catastro...

Context in source publication

Context 1
... this study, An existing five-story reinforced concrete building that was designed and built in Iran in the late 1970s has been considered for analysis, design and detailing of exterior beam column joint. (Figure 3). As with many building structures designed to codes created prior to the mid-1970s, the reinforcement is adequate for gravity and wind loads, but some of the details of the reinforcement are inadequate for earthquake forces if ductile behavior is required. ...

Similar publications

Book
Full-text available
This book presents experimental results and theoretical advances in the field of ultra-low-cycle fatigue failure of metal structures under strong earthquakes, where the dominant failure mechanism is ductile fracture. Studies on ultra-low-cycle fatigue failure of metal materials and structures have caught the interest of engineers and researchers fr...
Conference Paper
Full-text available
Pounding between structures during earthquakes has been a subject of research for many years, and researchers ‎have considered a variety of conditions of adjacent structures in their studies. The pounding phenomenon ‎includes some factors such as cracking, plastic deformation, energy dissipation, friction and fracture due to ‎impact. The purpose of...
Conference Paper
Full-text available
Buildings designed primarily for gravity loads are prone to suffer shear failures in walls, columns and beams when subjected to far field effects of earthquakes. In previous studies, pushover analyses carried out on these buildings were terminated when a local shear capacity is reached. However, by considering shear yielding, ductile shear hinges c...
Conference Paper
Full-text available
Older concrete beam-column joints that lack transverse reinforcement (unconfined joints) are susceptible to severe damage possibly contributing to building collapses during strong earthquakes. Tools to predict shear strength of joints with ductile details exist. In addition, many retrofit strategies for existing joints are available; however, tools...
Thesis
Full-text available
In most design codes, infill walls are considered as non-structural elements and thus are typically neglected in the design process. The observations made after major earthquakes (Duzce 1999, L’Aquila 2009, Christchurch 2011) have shown that even though infill walls are considered to be non-structural elements, they interact with the structural sys...