FIGURE 2 - uploaded by Shuvangkar Das
Content may be subject to copyright.
Circuit diagram of a three-phase grid tied inverter. The inverter consists of six switches paralleled by freewheeling diodes. A dc-link capacitor stores the voltage temporarily before transmitting it to the inverter. The inverter is connected to the AC grid by means of lines that are equivalent to RL branches.

Circuit diagram of a three-phase grid tied inverter. The inverter consists of six switches paralleled by freewheeling diodes. A dc-link capacitor stores the voltage temporarily before transmitting it to the inverter. The inverter is connected to the AC grid by means of lines that are equivalent to RL branches.

Source publication
Article
Full-text available
Power inverters are one of the devices of great importance used in power grids to convert DC to AC, especially for grids with attached solar panels or wind turbines. The world is getting warmer due to coal- and oil-based power generation. So human existence is threatened due to the increased amount of carbon-dioxide in the air. As a result, integra...

Contexts in source publication

Context 1
... basic circuit for a three-phase grid tied inverter is depicted in Figure 2. The sinusoidal three phase output voltage of inverter is as follows ...
Context 2
... gating signals are generated when PWM module interrupts. The interrupt service routine for the PWM module is shown in Figure 12. In this routine, the duty cycle for each pair of PWM output (PWMxH/PWMxL) is loaded in its associated PWM duty cycle register (PDCx). ...
Context 3
... components used in the hardware implementation of the proposed model has been presented as an image in Figure 20. The three-phase 400V, 50Hz AC signal output voltage of the inverter, which is fed to the grid, is sampled by a sensor board, which can be observed on the oscilloscope display, as shown in Figure 21. ...
Context 4
... components used in the hardware implementation of the proposed model has been presented as an image in Figure 20. The three-phase 400V, 50Hz AC signal output voltage of the inverter, which is fed to the grid, is sampled by a sensor board, which can be observed on the oscilloscope display, as shown in Figure 21. There is a control board and a switch board too. ...
Context 5
... serial converter aids to display the waveforms on the monitor. The monitor depicts the live control of the device, as shown in Figure 22. The monitor shows four waveforms: the PLL angles, and the three SVM phases, which are similar to Figure 8 (bottom) and Figure 14. ...
Context 6
... monitor shows four waveforms: the PLL angles, and the three SVM phases, which are similar to Figure 8 (bottom) and Figure 14. The complete hardware implementation setup is shown in the image of Figure 23. In the hardware implementation, a DC source is directly used instead of a PV system for the purpose of experimentation and convenience. ...

Similar publications

Conference Paper
Full-text available
In this paper, we present the effectiveness of using dynamic voltage restorer (DVR) in order to mitigate power quality disturbances like voltage sag, swell, short interruption, imbalance and fluctuation in three-phase distribution networks. This work investigates a basic architecture of DVR comprising phase locked loop (PLL) and proportional integr...
Article
Full-text available
This paper deals with the theoretical development, analysis, and simulation of the new topology of three-phase NPC (Neural Point Clamped) converter. The proposed 6-kW three-phase converter is connected to a three-phase electrical network and due to its bidirectional characteristics can either send energy to the grid or receive it from the grid. The...

Citations

... SVPWM-based inverters provide efficient power conversion by converting the direct current (DC) output of the fuel cell to grid-compatible alternating current (AC). This conversion ensures that the generated energy is easily absorbed into the existing power grid [47][48][49]. ...
... This can be achieved using the inverse matrices of Clarke and Park. The transformation matrices between the reference frames can be found in Shuvo et al. (2020). Fig. 1b presents the control approach based on the proposed optimal PR controllers with their HCs. ...
Article
Full-text available
In this paper, new optimal procedures are introduced to design the finest controllers and harmonic compensators (HCs) of three-level cascaded control for three-phase grid-supporting inverters based-AC microgrid. The three control levels, comprising primary, secondary and synchronization control levels, are developed in stationary αβ-frame and based on the proportional–integral (PI) controllers and the proportional-resonant controllers along with additional HCs. The new optimal design guidelines of microgrid’s controllers and HCs are aimed to fulfill the study requirements. The optimization objectives and constraints are employed to minimize both the total harmonic distortion (THD) and individual harmonics of microgrid’s voltage to enhance the quality of microgrid’s output power. The THD of microgrid’s voltage can be reduced to 0.19% under the nonlinear loads. Moreover, the microgrid’s voltage and frequency can be perfectly regulated with zero deviations. Furthermore, these new optimal procedures accelerate the speed of synchronization process between the external power grid and the microgrid to be accomplished in time less than 20 ms. Additionally, an accurate power-sharing among paralleled operated inverters can be achieved to avoid overstressing on any one. Also, seamless transitions can be guaranteed between grid-tied and isolated operation mode. The optimal controllers and HCs are designed by a new optimization algorithm called H-HHOPSO, which is created by hybridizing between Harris hawks optimization and particle swarm optimization algorithms. The effectiveness and robustness of the H-HHOPSO-based controllers and HCs are compared with other meta-heuristic optimization algorithms-based controllers and HCs. A microgrid, including two grid-supporting inverters based optimal controllers and optimal HCs, are modeled and carried out using MATLAB/SIMULINK to test the performance under linear and nonlinear loads, and also during the interruption of any one of two inverters. The performance is investigated according to IEC/IEEE harmonic standards, and compared with the conventional control strategy developed in synchronous dq-frame and based on only PI controllers.
... Pulsewidth modulation (PWM) inverters are primary component in active power filters [1], [2] static compensator (STATCOM) [3], [4] renewable energy systems [5], [6], and motor drives [7], [8]. It matches the output voltage with the reference on an average basis per carrier cycle. ...
... It is also subjected to two inequality constraints in which the phase voltage magnitude or DBU when (6) and (7) are adopted is at most 1% less than the corresponding values obtained by adopting Figure 4 scheme. Moreover, the THD from (6) and (7) is up to 1% higher than the THD resulted from applying the injections in Figures 4 and 5. Eventually, the presented polynomial scheme in (6) and (7) is the optimal combination of the two schemes in Figures 4 and 5. ...
Article
Full-text available
Pulswidth modulation (PWM) methods were developed to grant the voltage source inverter (VSI) output signal better quality measures. The PWM method that VSI relies on must consider the utilization of the direct current (DC) source, especially when the drive system works in the overmodulation region. In this paper, different zero-sequence harmonic injection PWM methods are proposed. Two essential objectives are optimized by minimizing total harmonic distortion and maximizing the DC bus utilization. All schemes’ results are compared with each other and with some of the commonly used PWM schemes. This paper concludes the usage of third, ninth, and fifteenth harmonic injections and any combination of them to reach a new PWM method that overtakes the disadvantages of other methods. Meanwhile, it provides a handy tool to operate VSI optimally. Ultimately, this work concludes to what extent is the zero-sequence injection is helpful. The work is evaluated experimentally, and the practical results match the simulation outcomes.
... The control technique of the grid-tied inverter relies on the grid synchronization technique. If the estimated angle is θ, then the a-b-c to d-q transformation can be given as [30]: ...
Article
Full-text available
The use of different control techniques has become very popular for controlling the performance of grid-connected photovoltaic (PV) systems. Although the proportional-integral (PI) control technique is very popular, there are some difficulties such as less stability, slow dynamic response, low reference tracking capability, and lower output power quality in solar PV applications. In this paper, a robust, fast, and dynamic proportional-integral resonance controller with a harmonic and lead compensator (PIR + HC + LC) is proposed to control the current of a 15-level neutral-pointclamped (NPC) multilevel inverter. The proposed controlled is basically a proportional-integral resonance (PIR) controller with the feedback of a harmonic compensator and a lead compensator. The performance of the proposed controller is analyzed in a MATLAB/Simulink environment. The simulation result represents admirable performance in terms of stability, sudden load change response, fault handling capability, reference tracking capability, and total harmonic distortion (THD) than those of the existing controllers. The responses of the inverter and grid outlets under different conditions are also analyzed. The harmonic compensator decreases the lower order harmonics of grid voltage and current, and the lead compensator provides the phase lead. It is expected that the proposed controller is a dynamic aspirant in the grid-connected PV system.
... The fast penetration of RES such as Photovoltaics (PVs) increases the popularity of DC-AC power converters at gridconnected applications [1][2][3][4][5]. However, the new PV architectures have independent PV modules with low input voltages [6][7][8][9]. ...
Article
Full-text available
The simple circuit based on DC-DC converters is the main attractive feature of the differential inverter topologies. It has a single-stage and provides modularity and scalability. However, the Negative Sequence Harmonic Component (NSHC) generated at the output terminal may hinder its practical applications. This paper presents a single-stage three-phase isolated differential inverter based on three High-Frequency Link (HFL) transformer-based DC-DC SEPIC converters. The utilized SEPIC converters perform voltage step-up/ down capability with galvanic isolation, which is essential for Renewable Energy Sources (RES). It mitigates the Common-Mode Voltage (CMV) and Electro-Magnetic Interference (EMI). Moreover, this paper proposes a two-loop based d-q synchronous frame grid-current control to mitigate its NSHC. A Type-II compensator and simple NSHC detection circuit are proposed to enhance the inverter's stability and compensate phase-delay of the utilized SEPIC converters. NSHC detection is developed using three cascaded Low Path Filters (LPFs). A 1.6kW inverter prototype was set to validate the performance of the proposed inverter and its control. The control is implemented by the MWPE3 C6713A Expert III DSP board. The proposed topology has a maximum efficiency of 89.744 at 700W output power and 86.4% at full power. The proposed control decreases the NSHC from 40.6 % to 1.614%, which shows its accuracy and precision. Furthermore, THD is reduced from 35.61% to 4.087% and satisfy the recent grid codes (<5%). The simulation results using PSIM software, power loss distribution, and a comparison study of the proposed inverter with similar topologies are also presented.