Circuit diagram of DFIG with basic hardware protection circuit.

Circuit diagram of DFIG with basic hardware protection circuit.

Source publication
Article
Full-text available
Aiming at the shortcomings of single-protection circuit in the low-voltage ride-through (LVRT) process of doubly-fed induction generators (DFIG), this paper proposes an integrated protection circuit strategy for LVRT of DFIG based super-capacitor(SC). The integrated protection circuit includes a Crowbar circuit, a rotor series dynamic resistance (S...

Context in source publication

Context 1
... integrated protection circuit structure adopted in this paper is shown in Figure 1. The DFIG adopts the strategy of integrated protection circuit of "Crowbar + SDR + SC". Figure 2 is the flowchart of integrated control strategy. ...

Similar publications

Article
Full-text available
Blue diode lasers are alternative curing devices for dental composites. The aim of this study was to investigate the influence of blue diode laser polymerization on shear bond strength of bulk fill composites to human dentin and temperature rise during two types of polymerization. Composite cylinders of SDR Plus(SDR) and Ever X Flow(EX) were bonded...
Article
Full-text available
This study assessed the influence of rapid 3 s light curing on the new generation of bulk-fill resin composites under the simulated aging challenge and depths up to 4 mm. Four bulk-fill materials were tested: two materials designed for rapid curing (Tetric PowerFill-PFILL; Tetric PowerFlow-PFLW) and two regular materials (Filtek One Bulk Fill Resto...
Article
Full-text available
Background In patients with knee osteoarthritis (KOA) undergoing knee arthroplasty (KA), lower-limb motor function tests are commonly measured during peri-surgical rehabilitation. To clarify their sources of variation and determine reference intervals (RIs), a multicenter study was performed in Japan. Methods We enrolled 545 KOA patients (127 men;...
Article
Full-text available
Background The purpose of this study was to evaluate the accuracy of automatic cephalometric landmark localization and measurements using cephalometric analysis via artificial intelligence (AI) compared with computer-assisted manual analysis. Methods Reconstructed lateral cephalograms (RLCs) from cone-beam computed tomography (CBCT) in 85 patients...
Article
Full-text available
Indigenous and were used to study genetic diversity and population structure analyses. Polymorphism information content (PIC) values ranged from 0.0 to 0.5, with 21,285 SNP markers (35%) being in the lowest PIC value range (0 to 0.15) while 13,511 (commercial chickens have developed unique adaptations to their environments, which may include nutrit...

Citations

Article
A Doubly Fed Induction Generator has a stator winding directly coupled with grid whereas rotor is to the grid via a fault-prone converter. In early times, when a fault occurred, these generators were required to disengage from the grid. However, due to the increased penetration, grid operators demanded WTs remain connected to the grid. Thus, this paperwork integrates crowbar protection with a Battery Energy Storage System (BESS) to improve Fault Ride Through (FRT) capability. For performance evaluation under transient conditions, a three-phase symmetrical fault is imposed at a time of 2 seconds. By using the suggested technique, the DC-link voltage is observed to improve and remain at 1150 V with minor fluctuation. Likewise, the stator and rotor currents are observed to remain at their nominal value after 2.15 seconds. MATLAB-Simulink software is used for modeling and simulation by obtaining all the system’s actual parameters from ADAMA-II Wind Farm.
Preprint
Doubly Fed Induction Generator (DFIG) has a stator winding directly coupled with grid. Whereas, rotor winding is connected via a fault-prone back to back power converters. DFIG is known to be vulnerable to the grid faults. In early times, when a fault occurred, these generators were required to disconnect from the grid to secure the generator and power converters. However, due to the increased penetration of wind turbines into the power system, grid operators demanded that the wind turbines remain connected to the grid, as disconnecting them would further disrupt the grid. When a fault at the grid terminal occur, a high stator current is induced which further result in high rotor current. This current will trigger the DC-link voltage to rise. This high currents and DC-link voltage will cause harm to the converters. Thus, in this paper work, the crowbar protection system is employed for protecting the converters against excess energy. Furthermore, the analysis of DFIG is rendered by integrating the crowbar protection with the Battery Energy Storage System (BESS) for a much effective outcome in enhancing machine to drive the fault. MATLAB-Simulink software is used for modeling and simulation. All system parameters are obtained from ADAMA-II Wind Farm.