Chest radiograph showing the location of the LVAD pump and outflow cannula (arrows) in relationship to the stomach.  

Chest radiograph showing the location of the LVAD pump and outflow cannula (arrows) in relationship to the stomach.  

Source publication
Article
Full-text available
A 74-year-old man with a left-ventricular assist device (LVAD) as destination therapy for end-stage ischemic cardiomyopathy presented with acute upper gastrointestinal bleeding. Other symptoms included chronic early satiety, intermittent nausea, and non-specific abdominal discomfort since LVAD implantation 3 years ago. An actively bleeding duodenal...

Similar publications

Article
Full-text available
While technological advances in the field of continuous-flow left ventricular assist device (CF-LVAD) are constantly being made, CF-LVAD recipients are still subjected to a relatively high rate of LVAD-related adverse events, with post-LVAD gastrointestinal bleeding (GIB) being the most common one. GIB is associated with a significant impairment in...
Article
Full-text available
Although patients receiving extracorporeal life support (ECLS) as a bridge to transplantation have demonstrated worse outcomes than those without ECLS, we investigated the key factors in the improvement of their posttransplant outcome. From December 2003 to December 2018, 257 adult patients who underwent heart transplantation (HTx) at our instituti...
Article
Full-text available
Syncope in patients with continuous-flow left ventricular assist device may be associated with arrhythmia and difficult to determine without an implantable cardioverter defibrillator. We present a patient with continuous-flow left ventricular assist device, no implantable cardioverter defibrillator, and recurrent syncope. An implantable loop record...

Citations

... LVAD patients experience several post-operative issues, including malnutrition [139,140]. Some patients develop an impaired nutritional state after LVAD implantation upon experiencing gastrointestinal disturbances that limit food intake (early satiety, decreased appetite, intermittent nausea, and vomiting) [141], likely due to the luminal compression exerted by the device [142], or bleeding [143]. Some others, instead, experience an exacerbation of a pre-existing undernourished or malnourished state after LVAD surgery. ...
... pression exerted by the device [142], or bleeding [143]. Some others, instead, experience an exacerbation of a pre-existing undernourished or malnourished state after LVAD surgery. ...
Article
Full-text available
Left ventricular assist devices (LVADs) represent the final treatment for patients with end-stage heart failure (HF) not eligible for transplantation. Although LVAD design has been further improved in the last decade, their use is associated with different complications. Specifically, inflammation, fibrosis, bleeding events, right ventricular failure, and aortic valve regurgitation may occur. In addition, reverse remodeling is associated with substantial cellular and molecular changes of the failing myocardium during LVAD support with positive effects on patients’ health. All these processes also lead to the identification of biomarkers identifying LVAD patients as having an augmented risk of developing associated adverse events, thus highlighting the possibility of identifying new therapeutic targets. Additionally, it has been reported that LVAD complications could cause or exacerbate a state of malnutrition, suggesting that, with an adjustment in nutrition, the general health of these patients could be improved.
Article
Nonsurgical bleeding (NSB) in heart failure (HF) patients with continuous-flow left ventricular assist device (CF-LVAD) support is the most common clinical complication. The aim of this study was to investigate the association between oxidative stress and platelet glycoproteins GPIbα and GPVI shedding on the incidence of NSB in CF-LVAD patients. Fifty-one HF patients undergoing CF-LVAD implantation and 11 healthy volunteers were recruited. Fourteen patients developed NSB (bleeder group) during 1 month follow-up duration, while others were considered nonbleeder group (n = 37). Several biomarkers of oxidative stress were quantified at baseline and weekly intervals in all patients. Surface expression and plasma elements of platelet receptor glycoproteins GPIbα and GPVI were measured. Oxidative stress biomarkers and platelet GPIbα and GPVI receptor-shedding (decreased surface expression and higher plasma levels) were found to be preexisting conditions in baseline samples of both groups of HF patients when compared with healthy volunteers. Significantly elevated oxidative stress biomarkers and platelet glycoprotein receptor shedding were observed in postimplant bleeder group temporarily when compared with nonbleeder group. Strong significant associations between biomarkers of oxidative stress and platelet glycoprotein receptor shedding were observed, suggesting a possible role of oxidative stress in platelet integrin shedding leading to NSB in CF-LVAD patients. Receiver operating characteristic analyses of GPIbα and GPVI indicated that the likelihood of NSB had a predictive power of bleeding complication in CF-LVAD patients. In conclusion, elevated oxidative stress may play a role in GPIbα and GPVI shedding in the event of NSB. Thus, oxidative stress and GPIbα and GPVI shedding may be used as potential biomarkers for bleeding risk stratification in those patients.