Error bar (mean ± STD) plots showing the trends in the variability of different ECG wave intervals (A, B) and SDI parameters (C, D) within the three groups. The arrow between the groups for a particular feature indicates that it can differentiate the groups with statistical significance. From panel (D), it is obvious that only the variability measures of beat-to-beat SDI parameter (vSDI TQ-RR ) can significantly differentiate all the three groups (CAN-, ECAN and DCAN) thus identifying the presence and progression of CAN. 5.4.1 Reproducibility of the SDI measure with ECG recording length variation An efficient measure should be reproducible at different data lengths. To evaluate the sensitivity of the SDI measures in CAN analysis with ECG data length, we calculated the values of different SDI measures by varying the length of ECG from 1 min to 5 min in addition to the results reported for a 10 min recording. The variation of the values of the SDI measures is shown in Figure 5-4. The values of mSDI QT-TQ and mSDI TQ-RR showed a consistent pattern in differentiating CAN-group form CAN positive groups (i.e. ECAN and DCAN) with ECG data length from 1 min up to 5 min and also for 10 min segment [Figure 

Error bar (mean ± STD) plots showing the trends in the variability of different ECG wave intervals (A, B) and SDI parameters (C, D) within the three groups. The arrow between the groups for a particular feature indicates that it can differentiate the groups with statistical significance. From panel (D), it is obvious that only the variability measures of beat-to-beat SDI parameter (vSDI TQ-RR ) can significantly differentiate all the three groups (CAN-, ECAN and DCAN) thus identifying the presence and progression of CAN. 5.4.1 Reproducibility of the SDI measure with ECG recording length variation An efficient measure should be reproducible at different data lengths. To evaluate the sensitivity of the SDI measures in CAN analysis with ECG data length, we calculated the values of different SDI measures by varying the length of ECG from 1 min to 5 min in addition to the results reported for a 10 min recording. The variation of the values of the SDI measures is shown in Figure 5-4. The values of mSDI QT-TQ and mSDI TQ-RR showed a consistent pattern in differentiating CAN-group form CAN positive groups (i.e. ECAN and DCAN) with ECG data length from 1 min up to 5 min and also for 10 min segment [Figure 

Similar publications

Article
Full-text available
Fetal electrocardiogram (FECG) records electrical activity of the fetal heart and is mainly referred for fetus heart condition. These signals are always contaminated with noises of various kinds which alter their characteristics and thus it may lead to wrong interpretation and diagnosis. Thus these signals need to be clean for correct diagnosis. In...

Citations

... The left ventricle (the largest and most powerful chamber) is responsible for pumping oxygen-rich blood throughout the body. The left ventricle's rapid contractions are responsible for our blood pressure [67] .The coronary arteries are blood vessels that run along the surface of the heart, supplying it with oxygen-rich blood to keep it working properly. In addition, a network of nerve tissue runs through the heart, carrying the complicated impulses that regulate contraction and relaxation to and from the brain [68] . ...